122 omconfig: Managing Components Using the Instrumentation Service
No information
Custom information
Default system information
Service tag, system name
Remote access MAC addresses
System power
Remote access IP address
Ambient temperature of the system
Remote access IPv4 address
Remote access IPv6 address
•Specify and configure the LCD line number
View the encryption state report of the LCD
Configure LCD to indicate an active remote session when the
K
ernel-
based
V
irtual
M
achine (KVM) is available
NOTE: You can configure the Power and NMI buttons only if they are present on
the system.
Table 4-6 shows the valid parameters for the command.
Table 4-6. omconfig chassis frontpanel or omconfig mainsystem frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=
<index>
NA Specifies the LCD line number.
config=none |
default | custom
NA none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.
text=<custom
text>
NA Sets the custom text for LCD when config=
custom.
nmibutton=
enable | disable
NA enable: Enables the NMI button on the
system.
disable: Disables the NMI button on the
system.