PowerEdge R210 II Technical Guide The PowerEdge R210 II offers performance, energy efficiency and ease of manageme
Dell PowerEdge R210 II Technical Guide 10 Feature R210 R210 II R310 USB 2 front, 2 back, 2 internal 2 front, 2 back, 2 internal 2 front, 2 back, 2
Dell PowerEdge R210 II Technical Guide 11 2 Key Technologies Key technologies on the Dell PowerEdge™ R210 II include the following: New proces
Dell PowerEdge R210 II Technical Guide 12 3 System Overview Table 2. Product Feature Summary Feature Technical Specification Form Factor 1U rack
Dell PowerEdge R210 II Technical Guide 13 Feature Technical Specification Communications Broadcom® NetXtreme® 5709 Dual Port Gigabit Ethernet NIC,
Dell PowerEdge R210 II Technical Guide 14 Feature Technical Specification configurations. If not configured according to the product documentation
Dell PowerEdge R210 II Technical Guide 15 4 Mechanical 4.1 Chassis Description The PowerEdge R210 II is a 1U rack-mount design that supports the
Dell PowerEdge R210 II Technical Guide 16 4.3 Front Panel View and Features Figure 2 and Figure 3 show the front views of the PowerEdge R210 II.
Dell PowerEdge R210 II Technical Guide 17 4.5 Power Button LED All Dell PowerEdge servers have a green LED integrated in the power button which in
Dell PowerEdge R210 II Technical Guide 18 Figure 6. Internal Chassis View 4.9 Rails 4.9.1 ReadyRails Static Rails ReadyRailsTM Static Rails fo
Dell PowerEdge R210 II Technical Guide 19 4.10 Fans There are three system fans located in the R210 II system. For information on removing and in
ii PowerEdge R210 II Technical Guide This document is for informational purposes only. Dell reserves the right to make changes wi
Dell PowerEdge R210 II Technical Guide 20 4.12.3 Hard Drive Cabled hard drives are only accessible by opening the top cover, thus locking the top
Dell PowerEdge R210 II Technical Guide 21 4.14 Battery A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power
Dell PowerEdge R210 II Technical Guide 22 5 Power, Thermal, Acoustic 5.1 Power Supplies The base system includes a single 250W power supply. This
Dell PowerEdge R210 II Technical Guide 23 5.4 Environmental Specifications The airborne contaminant level is class G2 or lower as defined by ISA-S
Dell PowerEdge R210 II Technical Guide 24 Table 5 shows the shock and vibration specifications for the R210 II. Table 5. Shock and Vibration Spec
Dell PowerEdge R210 II Technical Guide 25 in sound, like whistles and hums. One of the sound quality metrics in the Dell specification is the prom
Dell PowerEdge R210 II Technical Guide 26 Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activ
Dell PowerEdge R210 II Technical Guide 27 6 Processors 6.1 Overview The processors for the R210 II are based on the latest two- and four-core off
Dell PowerEdge R210 II Technical Guide 28 Model Speed (GHz) Power (Watts) Cores L3 Cache (MB) Threads Turbo Memory (MT/s) Process Intel Xeon E3-12
Dell PowerEdge R210 II Technical Guide 29 7 Memory 7.1 Overview The R210 II supports DDR3 memory, providing a high performance, high speed memory
iii PowerEdge R210 II Technical Guide Table of Contents 1 Product Comparison ...
Dell PowerEdge R210 II Technical Guide 30 Speed of the DIMMs Speed supported by the processor Configuration of the DIMMs The memory sp
Dell PowerEdge R210 II Technical Guide 31 System Capacity (GB) DIMM Quantity DIMM Type DIMM Speed (MT/s) Memory Channel Number of Ranks Memory Dat
Dell PowerEdge R210 II Technical Guide 32 8 Chipset 8.1 Overview The PowerEdge R210 II planar incorporates the Intel C200 Series PCH chipset. The
Dell PowerEdge R210 II Technical Guide 33 8.7 Low-Pin Count (LPC) Interface The LPC bridge function of the PCH resides in PCI Device 31: Function
Dell PowerEdge R210 II Technical Guide 34 8.11 USB Interface The C200 Series chipset contains up to two Enhanced Host Controller Interface (EHCI)
Dell PowerEdge R210 II Technical Guide 35 functions are designed to report errors, diagnose the system, and recover from system lockups without th
Dell PowerEdge R210 II Technical Guide 36 The chipset’s SMBus also implements hardware-based Packet Error Checking for data robustness and the Add
Dell PowerEdge R210 II Technical Guide 37 9 BIOS 9.1 Overview The R210 II BIOS is based on the Insyde® BIOS core which supports the following fe
Dell PowerEdge R210 II Technical Guide 38 Memory remapping support DDR3 UDIMM memory support UEFI shell Support AC recovery staggering
Dell PowerEdge R210 II Technical Guide 39 9.2.1.2 Maximum Performance The Maximum Performance Mode disables power management. In this mode, the p
iv PowerEdge R210 II Technical Guide 7.1 Overview ...
Dell PowerEdge R210 II Technical Guide 40 Table 12 shows the power profile options for the R210 II. Table 12. Power Profiles Maximum Performance
Dell PowerEdge R210 II Technical Guide 41 10 Embedded NICs/LAN on Motherboard (LOM) 10.1 Overview The PowerEdge R210 II includes a Broadcom® 5716C
Dell PowerEdge R210 II Technical Guide 42 IPv4 and IPv6 large send offload Jumbo MTU LSO and jumbo frames WOL capabilities Virtuali
Dell PowerEdge R210 II Technical Guide 43 11 PCI Slots 11.1 Overview The PowerEdge R210 II planar provides one riser card which provides one x16 G
Dell PowerEdge R210 II Technical Guide 44 12 Storage 12.1 Overview The PowerEdge R210 II supports the following hard drive configurations: 2 x
Dell PowerEdge R210 II Technical Guide 45 Non-Mixed Drives, all SATA, all SSD, or all SAS Config Type Configurations # Name Description M
Dell PowerEdge R210 II Technical Guide 46 The PERC S300 does not support Linux® operating systems or VMware® virtualization software. 12.4 Optica
Dell PowerEdge R210 II Technical Guide 47 13 Video The PowerEdge R210 II includes a Matrox® G200eW with 8 MB memory integrated in Winbond® WPCM450
Dell PowerEdge R210 II Technical Guide 48 14 Rack Information 14.1 Overview The ReadyRails™ static rail systems for the R210 II provide tool-less
Dell PowerEdge R210 II Technical Guide 49 Table 17. Rail Adjustability Ranges and Depth Product Rail ID Mounting Interface Rail Type Rail Adjusta
v PowerEdge R210 II Technical Guide 14.2 Rails ...
Dell PowerEdge R210 II Technical Guide 50 Figure 12. A6 Static Rail System Figure 13 shows a view of the R210 II mounted in the A4 A6 rail syste
Dell PowerEdge R210 II Technical Guide 51 Figure 14 shows the R210 II mounted in the A4 and A6 rail systems in the 2-post flush-mount configuratio
Dell PowerEdge R210 II Technical Guide 52 15 Operating Systems For detailed information, see the following: Operating System Support Matrix for
Dell PowerEdge R210 II Technical Guide 53 16 Systems Management 16.1 Overview Dell delivers open, comprehensive, and integrated solutions that hel
Dell PowerEdge R210 II Technical Guide 54 16.3 Embedded Server Management The PowerEdge R210 II implements circuitry for the next generation of Em
Dell PowerEdge R210 II Technical Guide 55 Feature Description Simplified Hardware Configuration Detects RAID controller and allows user to configu
Dell PowerEdge R210 II Technical Guide 56 Key features for the iDRAC6 Enterprise include: • Scripting capability with Dell’s Racadm command-line
Dell PowerEdge R210 II Technical Guide 57 Feature Base Management Functionality iDRAC6 Express iDRAC6 Enterprise vFlash Media Dedicated NIC
Dell PowerEdge R210 II Technical Guide 58 Feature Base Management Functionality iDRAC6 Express iDRAC6 Enterprise vFlash Media Trace Log
Dell PowerEdge R210 II Technical Guide 59 17 Peripherals The PowerEdge R210 II supports the following USB devices: DVD (bootable; requires two
vi PowerEdge R210 II Technical Guide Figures Figure 1. Chassis Dimensions ...
Dell PowerEdge R210 II Technical Guide 60 Appendix A. Statement of Volatility The Dell PowerEdge R210 II contains both volatile and non-volatile
Dell PowerEdge R210 II Technical Guide 61 LOM (LAN [Network Interface] on Motherboard) Memory Details: Size: 4Mb (512KB) Type [e.g. Flash PROM
Dell PowerEdge R210 II Technical Guide 62 TPM (Trusted Platform Module; For boards shipped outside of China; Boards sold to destinations in
Dell PowerEdge R210 II Technical Guide 63 Appendix B. Certifications B 1. Regulatory Certifications Regulatory compliance certificates can be lo
Dell PowerEdge R210 II Technical Guide 64 Country/Region Authority or Mark United States NRTL Uzbekistan STZ B 3. Electromagnetic Compatibility
Dell PowerEdge R210 II Technical Guide 65 Table 23. Ergonomics, Acoustics and Hygienics Country/Region Authority or Mark Belarus BELLIS Germany G
Dell PowerEdge R210 II Technical Guide 66 Appendix C. Industry Standards The PowerEdge R210 II system conforms to the industry standards detailed
Dell PowerEdge R210 II Technical Guide 67 Standard URL for Information and Specifications UEFI Unified Extensible Firmware Interface Specification
Dell PowerEdge R210 II Technical Guide 7 1 Product Comparison 1.1 Overview The PowerEdge R210 II is an entry-level, yet enterprise ready, ultra-d
Dell PowerEdge R210 II Technical Guide 8 functionality as well as offering email, remote access, and collaboration to help take your business to t
Dell PowerEdge R210 II Technical Guide 9 Feature R210 R210 II R310 DIMMs 4 DDR3 1066/1333MT/s 4 DDR3 up to 1600MT/s 6 DDR3 1066/1333MT/s Min/Max R