Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Komponenty podvozku Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS. Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS SNMP Reference Guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 834
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Dell OpenManage
Server Administrator
SNMP Reference Guide
Version 7.1.2
book.book Page 1 Wednesday, March 6, 2013 12:37 AM
Zobrazit stránku 0
1 2 3 4 5 6 ... 833 834

Shrnutí obsahu

Strany 1 - Version 7.1.2

Dell OpenManageServer AdministratorSNMP Reference Guide Version 7.1.2book.book Page 1 Wednesday, March 6, 2013 12:37 AM

Strany 2 - Notes and Cautions

10 ContentsBaseboard Management Controller Group Variable Values . . . . . . . . . . . . . . . . . . . . . 54522 Field Replaceable Unit Group . . . .

Strany 3 - Contents

102 Chassis Information GroupIntrusion IndexIntrusion State CapabilitiesIntrusion State SettingsIntrusion StatusName intrusionIndexObject ID 1.3.6.1.4

Strany 4 - 4 Contents

Chassis Information Group 103Intrusion ReadingIntrusion TypeIntrusion Location NameBaseboard TableThis table lists objects that define the baseboard o

Strany 5

104 Chassis Information GroupBaseboard Table EntryBaseboard Chassis IndexBaseboard IndexBaseboard State CapabilitiesName baseBoardTableEntryObject ID

Strany 6 - 6 Contents

Chassis Information Group 105Baseboard State SettingsBaseboard StatusBaseboard Feature FlagsBaseboard TypeName baseBoardStateSettings Object ID 1.3.6.

Strany 7

106 Chassis Information GroupBaseboard Type NameBaseboard Location NameBaseboard Manufacturer NameBaseboard Product NameName baseBoardTypeNameObject I

Strany 8 - 8 Contents

Chassis Information Group 107Baseboard Version NameBaseboard Service Tag NameBaseboard Piece Part ID (PPID) NameBaseboard Asset Tag NameName baseBoard

Strany 9 - 21 Baseboard Management

108 Chassis Information GroupBaseboard Express Service Code NameChassis Information Group Variable ValuesThis section includes definitions for server

Strany 10 - 10 Contents

Chassis Information Group 109tower(7) The chassis type is a tower.portable(8) The chassis type is a portable.lapTop(9) The chassis type is a laptop.no

Strany 11

110 Chassis Information GroupTable 5-3. Connection StatusVariable Name: DellConnectionStatusData Type: IntegerPossible Data Values Meaning of Data Val

Strany 12 - 27 Storage Management

Chassis Information Group 111Table 5-6. Front-Panel LED Control SettingsVariable Name: DellLEDControlSettingsData Type: IntegerPossible Data Values Me

Strany 13

Contents 11Logical Devices Group . . . . . . . . . . . . . . . . . 672Virtual Disk Table. . . . . . . . . . . . . . . . . . 672Virtual Disk Partiti

Strany 14 - 14 Contents

112 Chassis Information GroupTable 5-8. Hard-Drive Fault LED Control SettingsVariable Name: DellHDFaultLEDControlSettingsData Type: IntegerPossible Da

Strany 15 - Introduction

Chassis Information Group 113NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to

Strany 16 - Supported SNMP Versions

114 Chassis Information GroupTable 5-11. Host Control CapabilitiesVariable Name: DellHostControlCapabilitiesNOTE: An operator can manually enable thes

Strany 17

Chassis Information Group 115Table 5-12. Host Control SettingsVariable Name: DellHostControlSettingsNOTE: An operator can manually cause these actions

Strany 18 - 20 Introduction

116 Chassis Information GroupautomaticAllExceptNotificationCapable(27)Watchdog controls can be set to automatically perform all functions except notif

Strany 19

Chassis Information Group 117Table 5-15. Watchdog Timer CapabilitiesVariable Name: DellWatchDogTimerCapabilitiesData Type: IntegerPossible Data Values

Strany 20

118 Chassis Information GroupTable 5-18. NMI Button Control CapabilitiesVariable Name: DellNMIButtonControlCapabilitiesData Type: IntegerPossible Data

Strany 21

Chassis Information Group 119Table 5-21. Baseboard TypeVariable Name: DellBaseBoardTypeData Type: IntegerPossible Data Values Meaning of Data Valueunk

Strany 22

120 Chassis Information GroupdesktopClass(5) The chassis system class is a desktop.portableClass(6) The chassis system class is a portable.netPCClass(

Strany 23

Chassis Information Group 121hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller.sensorData(12) The firmwa

Strany 24 - SNMP Basic Terminology

12 ContentsLegacy Alerting . . . . . . . . . . . . . . . . . . . . . 73626 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . 739Understa

Strany 25 - Introduction 27

122 Chassis Information GroupboardRequiresDaughterBoard(2)This baseboard requires at least one daughter board or auxiliary card.boardIsRemovable(4) Th

Strany 26

Operating System Group 1236Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating sys

Strany 27 - Introduction 29

124 Operating System GroupOperating System Chassis IndexOperating System State CapabilitiesOperating System State SettingsOperating System StatusName

Strany 28 - UUID Table

Operating System Group 125Operating System Is PrimaryOperating System NameOperating System Version NameOperating System Memory TableName operatingSyst

Strany 29 - UUID Type

126 Operating System GroupOperating System Memory Table EntryOperating System Memory Chassis IndexOperating System Memory State CapabilitiesOperating

Strany 30 - UUID Value

Operating System Group 127Operating System Memory StatusOperating System Memory Total Physical SizeOperating System Memory Available Physical SizeOper

Strany 31 - Section Organization

128 Operating System GroupOperating System Memory Available Page File SizeOperating System Memory Total Virtual SizeOperating System Memory Available

Strany 32 - SNMP Subagent

Operating System Group 129book.book Page 129 Wednesday, March 6, 2013 12:37 AM

Strany 33 - Introduction 35

130 Operating System Groupbook.book Page 130 Wednesday, March 6, 2013 12:37 AM

Strany 34

System Resource Group 1317System Resource GroupThe Management Information Base (MIB) variables presented in this section enable you to track various a

Strany 35 - SNMP Security

Contents 13Alert Severity Levels . . . . . . . . . . . . . . . . . . 782SNMP Support for Storage Management Alerts . . . . 783SNMP Trap Forwarding

Strany 36 - SNMP Traps

132 System Resource GroupSystem Resource Map Table EntrySystem Resource Map Chassis IndexSystem Resource Map IndexSystem Resource Map State Capabiliti

Strany 37 - Introduction 39

System Resource Group 133System Resource Map State SettingsSystem Resource Map StatusSystem Resource Map TypeSystem Resource Owner TableName systemRes

Strany 38 - 40 Introduction

134 System Resource GroupSystem Resource Owner Table EntrySystem Resource Owner Chassis IndexSystem Resource Owner IndexSystem Resource Owner State Ca

Strany 39

System Resource Group 135System Resource Owner State SettingsSystem Resource Owner StatusSystem Resource Owner Interface TypeSystem Resource Map Index

Strany 40 - Version Number

136 System Resource GroupSystem Resource Owner Description NameSystem Resource Owner Interface InstanceSystem Resource Input/Output (I/O) Port TableSy

Strany 41 - Systems Management Software

System Resource Group 137System Resource I/O Port Chassis IndexSystem Resource I/O Port IndexSystem Resource I/O Port State CapabilitiesSystem Resourc

Strany 42

138 System Resource GroupSystem Resource I/O Port StatusSystem Resource I/O Port Owner Index ReferenceSystem Resource I/O Port Share DispositionSystem

Strany 43

System Resource Group 139System Resource I/O Port Ending AddressSystem Resource Memory TableSystem Resource Memory Table EntrySystem Resource Memory C

Strany 44

140 System Resource GroupSystem Resource Memory IndexSystem Resource Memory State CapabilitiesSystem Resource Memory State SettingsSystem Resource Mem

Strany 45 - SMSSupportedTypes

System Resource Group 141System Resource Memory Owner Index ReferenceSystem Resource Memory Share DispositionSystem Resource Memory Starting AddressSy

Strany 46 - SMSSNMPAgentFeatureFlags

14 ContentsVariables with Data Types of State Capabilities and State Capabilities Unique. . . . . . . . . . . . . . . . 820Dell Status Data Types. .

Strany 47 - System State Group

142 System Resource GroupSystem Resource Memory FlagsSystem Resource Interrupt TableSystem Resource Interrupt Table EntrySystem Resource Interrupt Cha

Strany 48

System Resource Group 143System Resource Interrupt IndexSystem Resource Interrupt State CapabilitiesSystem Resource Interrupt State SettingsSystem Res

Strany 49 - System State Table

144 System Resource GroupSystem Resource Interrupt Owner Index ReferenceSystem Resource Interrupt Owner Share DispositionSystem Resource Interrupt Lev

Strany 50 - 52 System State Group

System Resource Group 145System Resource Interrupt TriggerSystem Resource Direct Memory Access (DMA) TableSystem Resource DMA Table EntrySystem Resour

Strany 51

146 System Resource GroupSystem Resource DMA IndexSystem Resource DMA State CapabilitiesSystem Resource DMA State SettingsSystem Resource DMA StatusNa

Strany 52 - 54 System State Group

System Resource Group 147System Resource DMA Owner Index ReferenceSystem Resource DMA Share DispositionSystem Resource DMA Maximum Transfer SizeSystem

Strany 53

148 System Resource GroupSystem Resource DMA Bus MasterSystem Resource Group Variable ValuesThis section includes definitions for server administrator

Strany 54 - 56 System State Group

System Resource Group 149typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus.typeIsMCA(6) The interface type is

Strany 55

150 System Resource GroupTable 7-5. Resource Interrupt TypeVariable Name: DellResourceInterruptTypeData Type: IntegerPossible Data Values Meaning of D

Strany 56 - 58 System State Group

System Resource Group 151Table 7-8. Resource DMA Transfer WidthVariable Name: DellResourceDMATransferWidthData Type: IntegerPossible Data Values Meani

Strany 57

Template Last Updated - 2/7/2007 Introduction 17DELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY1IntroductionThis reference guide provides info

Strany 58 - 60 System State Group

152 System Resource Groupbook.book Page 152 Wednesday, March 6, 2013 12:37 AM

Strany 59

Power Group 1538Power GroupThe Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and

Strany 60 - 62 System State Group

154 Power GroupPower Unit Table EntryPower Unit Chassis IndexPower Unit IndexPower Unit State CapabilitiesName powerUnitTableEntry Object ID 1.3.6.1.4

Strany 61

Power Group 155Power Unit State SettingsPower Unit Redundancy StatusPower Supply Count for RedundancyPower Unit NameName powerUnitStateSettings Object

Strany 62 - 64 System State Group

156 Power GroupPower Unit StatusPower Supply TablePower Supply Table EntryPower Supply Chassis IndexName powerUnitStatusObject ID 1.3.6.1.4.1.674.1089

Strany 63 - System State Event Log Status

Power Group 157Power Supply IndexPower Supply State Capabilities UniquePower Supply State Settings UniquePower Supply StatusName powerSupplyIndexObjec

Strany 64 - 66 System State Group

158 Power GroupPower Supply Output WattsPower Supply TypePower Supply Location NamePower Supply Input VoltageName powerSupplyOutputWattsObject ID 1.3.

Strany 65

Power Group 159Power Supply Power Unit Index ReferencePower Supply Sensor StatePower Supply Configuration Error TypePower Supply Power Monitor Capable

Strany 66 - 68 System State Group

160 Power GroupPower Supply Rated Input WattageVoltage Probe TableVoltage Probe Table EntryVoltage Probe Chassis IndexName powerSupplyRatedInputWattag

Strany 67

Power Group 161Voltage Probe IndexVoltage Probe State CapabilitiesVoltage Probe State SettingsVoltage Probe StatusName voltageProbeIndexObject ID 1.3.

Strany 68 - 70 System State Group

18 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYdeprecated, refer to

Strany 69 - Chassis Information Group

162 Power GroupVoltage Probe ReadingVoltage Probe TypeVoltage Probe Location NameVoltage Probe Upper Nonrecoverable ThresholdName voltageProbeReadingO

Strany 70 - 72 Chassis Information Group

Power Group 163Voltage Probe Upper Critical ThresholdVoltage Probe Upper Noncritical ThresholdVoltage Probe Lower Noncritical ThresholdAccess Read-onl

Strany 71 - Chassis Name

164 Power GroupVoltage Probe Lower Critical ThresholdVoltage Probe Lower Nonrecoverable ThresholdVoltage Probe Probe CapabilitiesName voltageProbeLowe

Strany 72 - 74 Chassis Information Group

Power Group 165Voltage Probe Discrete ReadingAmperage Probe TableAmperage Probe Table EntryName voltageProbeDiscreteReadingObject ID 1.3.6.1.4.1.674.1

Strany 73 - Chassis System Name

166 Power GroupAmperage Probe Chassis IndexAmperage Probe IndexAmperage Probe State CapabilitiesAmperage Probe State SettingsName amperageProbechassis

Strany 74 - 76 Chassis Information Group

Power Group 167Amperage Probe StatusAmperage Probe ReadingName amperageProbeStatusObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.5Description Defines the

Strany 75

168 Power GroupAmperage Probe TypeAmperage Probe Location NameAmperage Probe Upper Nonrecoverable ThresholdAmperage Probe Upper Critical ThresholdName

Strany 76 - 78 Chassis Information Group

Power Group 169Amperage Probe Upper Noncritical ThresholdAmperage Probe Lower Noncritical ThresholdAmperage Probe Lower Critical ThresholdName amperag

Strany 77 - Chassis Lock Present

170 Power GroupAmperage Probe Lower Nonrecoverable ThresholdAmperage Probe Probe CapabilitiesAmperage Probe Discrete ReadingName amperageProbeLowerNon

Strany 78 - 80 Chassis Information Group

Power Group 171AC Power Switch TableAC Power Switch Table EntryAC Power Switch Chassis IndexAC Power Switch IndexName aCPowerSwitchTableObject ID 1.3.

Strany 79

Introduction 19FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYServer Administrator

Strany 80 - 82 Chassis Information Group

172 Power GroupAC Power Switch CapabilitiesAC Power Switch SettingsAC Power Switch Redundancy StatusAC Power Cord Count for RedundancyName aCPowerSwit

Strany 81 - Chassis System Properties

Power Group 173AC Power Switch NameAC Power Switch Redundancy ModeAC Power Switch StatusAC Power Cord TableName aCPowerSwitchNameObject ID 1.3.6.1.4.1

Strany 82

174 Power GroupAC Power Cord Table EntryAC Power Cord Chassis IndexAC Power Cord IndexAC Power Cord State CapabilitiesName aCPowerCordTableEntryObject

Strany 83

Power Group 175AC Power Cord State SettingsAC Power Cord StatusAC Power Cord AC Power Switch Index ReferenceAC Power Cord Location NameName aCPowerCor

Strany 84 - POST Log Table

176 Power GroupBattery TableBattery Table EntryBattery Chassis IndexBattery IndexName batteryTableObject ID 1.3.6.1.4.1.674.10892.1.600.50Description

Strany 85 - POST Log Record Index

Power Group 177Battery State CapabilitiesBattery State SettingsBattery StatusBattery ReadingName batteryStateCapabilitiesObject ID 1.3.6.1.4.1.674.108

Strany 86 - Event Log Table

178 Power GroupBattery Location NamePower Usage TablePower Usage Table EntryPower Usage Chassis IndexName batteryLocationNameObject ID 1.3.6.1.4.1.674

Strany 87 - Event Log Record Index

Power Group 179Power Usage IndexPower Usage State CapabilitiesPower Usage State SettingsPower Usage StatusName powerUsageIndexObject ID 1.3.6.1.4.1.67

Strany 88 - 90 Chassis Information Group

180 Power GroupPower Usage Entity NamePower Usage Cumulative WattagePower Usage Cumulative Wattage Start Date NamePower Usage Peak WattsName powerUsag

Strany 89 - System BIOS Table

Power Group 181Power Usage Peak Watts Start Date NamePower Usage Peak Watts Reading Date NamePower Usage Peak AmpsDescription Defines the peak wattage

Strany 90 - 92 Chassis Information Group

20 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY6 Operating System G

Strany 91 - System BIOS Starting Address

182 Power GroupPower Usage Peak Amps Start Date NamePower Usage Peak Amps Reading Date NamePower Usage Idle PowerPower Usage Max Potential PowerName p

Strany 92 - 94 Chassis Information Group

Power Group 183Power Usage Power Cap CapabilitiesPower Usage Power Cap SettingPower Usage Power Cap ValueDescription Defines the maximum potential pow

Strany 93

184 Power GroupPower Usage Instantaneous HeadroomPower Usage Peak HeadroomPower Profile TablePower Profile Table EntryName powerUsageInstantaneousHead

Strany 94 - 96 Chassis Information Group

Power Group 185Power Profile Chassis IndexPower Profile IndexPower Profile Supported ProfilesPower Profile SettingAccess Not accessibleIndex powerProf

Strany 95

186 Power GroupPower Profile Custom CPU Management CapabilitiesPower Profile Custom CPU Management SettingPower Profile Custom Memory Management Capab

Strany 96 - Firmware Table

Power Group 187Power Profile Custom Memory Management SettingPower Profile Custom Fan Management CapabilitiesPower Profile Custom Fan Management Setti

Strany 97 - Firmware Size

188 Power GroupTable 8-1. Power Supply State Capabilities UniqueVariable Name: DellPowerSupplyStateCapabilitiesUniqueData Type: IntegerPossible Data V

Strany 98 - 100 Chassis Information Group

Power Group 189onlineAndPredictiveFailure(210)The power supply is online and indicating that it has a problem.acPowerAndSwitchAreOnPowerSupplyIsOnIsOk

Strany 99 - Intrusion Table

190 Power GrouppowerSupplyTypeIsDC(10) The power supply type is a DC power supply.powerSupplyTypeIsVRM(11) The power supply type is a voltage regulato

Strany 100 - 102 Chassis Information Group

Power Group 191Table 8-5. Power Supply Configuration Error TypeVariable Name: DellPowerSupplyConfigurationErrorTypeData Type: IntegerPossible Data Val

Strany 101 - Baseboard Table

Introduction 21FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYServer Administrator

Strany 102 - 104 Chassis Information Group

192 Power GroupvoltageProbeTypeIsCore(10) The voltage probe type is a core volt probe.voltageProbeTypeIsFLEA(11) The voltage probe type is a FLEA (sta

Strany 103 - Baseboard Feature Flags

Power Group 193Table 8-8. Amperage Probe DefinitionsVariable Name: DellAmperageTypeData Type: IntegerPossible Data Values Meaning of Data Valueamperag

Strany 104 - 106 Chassis Information Group

194 Power GroupamperageProbeTypeIs2Point5Volt(14) The amperage probe type is a 2.5-V amperage probe.amperageProbeTypeIsGTL(15) The amperage probe type

Strany 105 - Baseboard Asset Tag Name

Power Group 195Table 8-10. AC Power Switch CapabilitiesVariable Name: DellACPowerSwitchCapabilitiesData Type: IntegerPossible Data Values Meaning of D

Strany 106 - DellLogFormat

196 Power GroupTable 8-12. AC Power Switch Redundancy ModeVariable Name: DellACPowerSwitchRedundancyModeData Type: IntegerPossible Data Values Meaning

Strany 107 - (continued)

Power Group 197Table 8-15. Battery ReadingVariable Name: DellBatteryReadingData Type: IntegerNOTE: These values are bit masks, so combination values a

Strany 108

198 Power GroupTable 8-18. Power Profile TypeVariable Name: DellPowerProfileTypeData Type: IntegerNOTE: These values are bit masks, so combination val

Strany 109 - DellLEDControlSettings

Power Group 199Table 8-20. Memory Power Performance Management TypeVariable Name: DellMemoryPowerPerformanceManagementTypeData Type: IntegerNOTE: Thes

Strany 110 - DellHDFaultLEDControlSettings

200 Power Groupbook.book Page 200 Wednesday, March 6, 2013 12:37 AM

Strany 111

Thermal Group 2019Thermal GroupThe Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are

Strany 112 - DellHostControlCapabilities

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. A CAUTION indicates potential damag

Strany 113

22 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYServer Administrator

Strany 114

202 Thermal GroupCooling Unit Chassis IndexCooling Unit IndexCooling Unit State CapabilitiesCooling Unit State SettingsName coolingUnitchassisIndex Ob

Strany 115

Thermal Group 203Cooling Unit Redundancy StatusCooling Device Count For RedundancyCooling Unit NameCooling Unit StatusName coolingUnitRedundancyStatus

Strany 116

204 Thermal GroupCooling Device TableCooling Device Table EntryCooling Device Chassis IndexCooling Device Index Name coolingDeviceTable Object ID 1.3.

Strany 117 - DellChassisSystemClass

Thermal Group 205Cooling Device State CapabilitiesCooling Device State SettingsCooling Device StatusName coolingDeviceStateCapabilitiesObject ID 1.3.6

Strany 118 - DellFirmwareType

206 Thermal GroupCooling Device ReadingCooling Device TypeCooling Device Location NameName coolingDeviceReadingObject ID 1.3.6.1.4.1.674.10892.1.700.1

Strany 119

Thermal Group 207Cooling Device Upper Nonrecoverable ThresholdCooling Device Upper Critical ThresholdCooling Device Upper Noncritical ThresholdCooling

Strany 120 - DellBaseBoardFeatureFlags

208 Thermal GroupCooling Device Lower Critical ThresholdCooling Device Lower Nonrecoverable ThresholdCooling Device Cooling Unit Index ReferenceCoolin

Strany 121 - Operating System Group

Thermal Group 209Cooling Device Probe CapabilitiesCooling Device Discrete ReadingTemperature Probe TableName coolingDeviceProbeCapabilitiesObject ID 1

Strany 122 - 124 Operating System Group

210 Thermal GroupTemperature Probe Table EntryTemperature Probe Chassis IndexTemperature Probe Index Temperature Probe State CapabilitiesName temperat

Strany 123 - Operating System Memory Table

Thermal Group 211Temperature Probe State SettingsTemperature Probe StatusTemperature Probe ReadingName temperatureProbeStateSettings Object ID 1.3.6.1

Strany 124 - 126 Operating System Group

Introduction 23FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYServer Administrator

Strany 125

212 Thermal GroupTemperature Probe TypeTemperature Probe Location NameTemperature Probe Upper Nonrecoverable ThresholdTemperature Probe Upper Critical

Strany 126 - 128 Operating System Group

Thermal Group 213Temperature Probe Upper Noncritical ThresholdTemperature Probe Lower Noncritical ThresholdTemperature Probe Lower Critical ThresholdT

Strany 127 - Operating System Group 129

214 Thermal GroupTemperature Probe Probe CapabilitiesTemperature Probe Discrete ReadingName temperatureProbeProbeCapabilitiesObject ID 1.3.6.1.4.1.674

Strany 128 - 130 Operating System Group

Thermal Group 215Thermal Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section

Strany 129 - System Resource Group

216 Thermal GroupTable 9-2. Cooling Device SubtypeVariable Name: DellCoolingDeviceSubTypeData Type: IntegerPossible Data Values Meaning of Data Valuec

Strany 130 - 132 System Resource Group

Thermal Group 217Table 9-4. Temperature Probe TypeVariable Name: DellTemperatureProbeTypeData Type: IntegerPossible Data Values Meaning of Data Valuet

Strany 131 - System Resource Owner Table

218 Thermal Groupbook.book Page 218 Wednesday, March 6, 2013 12:37 AM

Strany 132 - 134 System Resource Group

User Security Group 21910User Security GroupThe User Security Table defines the objects that allow administrators to create and modify user accounts a

Strany 133 - System Resource Owner Status

220 User Security GroupUser Security Chassis IndexUser Security IndexUser Security User NameUser Security Control NameName userSecuritychassisIndex Ob

Strany 134 - 136 System Resource Group

User Security Group 221User Security Request NameName userSecurityRequestNameObject ID 1.3.6.1.4.1.674.10892.1.800.1.5Description Defines a request na

Strany 135

24 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYServer Administrator

Strany 136 - 138 System Resource Group

222 User Security Groupbook.book Page 222 Wednesday, March 6, 2013 12:37 AM

Strany 137 - System Resource Memory Table

Remote Flash BIOS Group 22311Remote Flash BIOS GroupThe Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely upd

Strany 138 - 140 System Resource Group

224 Remote Flash BIOS GroupRemote Flash BIOS Chassis IndexRemote Flash BIOS IndexRemote Flash BIOS State Capabilities UniqueRemote Flash BIOS State Se

Strany 139

Remote Flash BIOS Group 225Remote Flash BIOS StatusRemote Flash BIOS Last BIOS Date NameRemote Flash BIOS Completion CodeRemote Flash BIOS Minimum Con

Strany 140 - 142 System Resource Group

226 Remote Flash BIOS GroupRemote Flash BIOS Variable ValuesThis section includes definitions for server administrator-specific variable values used i

Strany 141

Remote Flash BIOS Group 227Table 11-3. Remote Flash BIOS Completion CodeVariable Name: DellRemoteFlashBIOSCompletionCodeData Type: IntegerPossible Dat

Strany 142 - 144 System Resource Group

228 Remote Flash BIOS Groupbook.book Page 228 Wednesday, March 6, 2013 12:37 AM

Strany 143

Port Group 22912Port GroupThe Port Group provides information about the different types of ports that may be present in your system. This management i

Strany 144 - 146 System Resource Group

230 Port GroupPointing Port Table EntryPointing Port Chassis IndexPointing Port IndexPointing Port State CapabilitiesName pointingPortTableEntryObject

Strany 145

Port Group 231Pointing Port State SettingsPointing Port StatusPointing Port Security StatePointing Port Connector TypeName pointingPortStateSettingsOb

Strany 146

Introduction 25FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTable 1-7. Dell RAC

Strany 147

232 Port GroupPointing Port NamePointing Port BIOS Connector TypeKeyboard Port TableKeyboard Port Table EntryName pointingPortName Object ID 1.3.6.1.4

Strany 148

Port Group 233Keyboard Port Chassis IndexKeyboard Port IndexKeyboard Port State CapabilitiesKeyboard Port State SettingsName keyboardPortchassisIndexO

Strany 149 - DellResourceDMATransferWidth

234 Port GroupKeyboard Port StatusKeyboard Port Security StateKeyboard Port Connector TypeKeyboard Port NameName keyboardPortStatusObject ID 1.3.6.1.4

Strany 150 - 152 System Resource Group

Port Group 235Keyboard Port BIOS Connector TypeProcessor Port TableProcessor Port Table EntryProcessor Port Chassis IndexName keyboardPortBIOSConnecto

Strany 151 - Power Group

236 Port GroupProcessor Port IndexProcessor Port State CapabilitiesProcessor Port State SettingsProcessor Port StatusName processorPortIndexObject ID

Strany 152 - 154 Power Group

Port Group 237Processor Port Security StateProcessor Port Connector TypeProcessor Port NameProcessor Port BIOS Connector TypeName processorPortSecurit

Strany 153 - Power Unit Name

238 Port GroupMemory Device Port TableMemory Device Port Table EntryMemory Device Port Chassis IndexMemory Device Port IndexName memoryDevicePortTable

Strany 154 - Power Supply Table

Port Group 239Memory Device Port State CapabilitiesMemory Device Port State SettingsMemory Device Port StatusMemory Device Port Security StateName mem

Strany 155 - Power Supply Status

240 Port GroupMemory Device Port Connector TypeMemory Device Port NameMemory Device Port BIOS Connector TypeMemory Device Port Physical Memory Array I

Strany 156 - 158 Power Group

Port Group 241Memory Device Port Physical Memory Card Index ReferenceMonitor Port TableMonitor Port Table EntryMonitor Port Chassis IndexName memoryDe

Strany 157 - Power Supply Sensor State

26 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSNMP Basic Terminolo

Strany 158 - Voltage Probe Table

242 Port GroupMonitor Port IndexMonitor Port State CapabilitiesMonitor Port State SettingsMonitor Port StatusName monitorPortIndexObject ID 1.3.6.1.4.

Strany 159 - Voltage Probe Status

Port Group 243Monitor Port Security StateMonitor Port Connector TypeMonitor Port NameMonitor Port BIOS Connector TypeName monitorPortSecurityState Obj

Strany 160 - 162 Power Group

244 Port GroupSmall Computer System Interface (SCSI) Port TableSCSI Port Table EntrySCSI Port Chassis IndexSCSI Port IndexName sCSIPortTableObject ID

Strany 161

Port Group 245SCSI Port State CapabilitiesSCSI Port State SettingsSCSI Port StatusSCSI Port Security StateName sCSIPortStateCapabilities Object ID 1.3

Strany 162 - 164 Power Group

246 Port GroupSCSI Port Connector TypeSCSI Port NameSCSI Port BIOS Connector TypeParallel Port TableName sCSIPortConnectorType Object ID 1.3.6.1.4.1.6

Strany 163 - Amperage Probe Table

Port Group 247Parallel Port Table EntryParallel Port Chassis IndexParallel Port IndexParallel Port State CapabilitiesName parallelPortTableEntryObject

Strany 164 - 166 Power Group

248 Port GroupParallel Port State SettingsParallel Port StatusParallel Port Security StateParallel Port Connector TypeName parallelPortStateSettingsOb

Strany 165 - Amperage Probe Reading

Port Group 249Parallel Port NameParallel Port Connector Pin OutParallel Port Capabilities UniqueParallel Port Base I/O AddressName parallelPortNameObj

Strany 166 - 168 Power Group

250 Port GroupParallel Port IRQ LevelParallel Port DMA SupportSerial Port TableSerial Port Table EntryName parallelPortIRQLevelObject ID 1.3.6.1.4.1.6

Strany 167

Port Group 251Serial Port Chassis IndexSerial Port IndexSerial Port State CapabilitiesSerial Port State SettingsName serialPortchassisIndexObject ID 1

Strany 168 - 170 Power Group

Introduction 27FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYThe SNMP extension a

Strany 169 - AC Power Switch Table

252 Port GroupSerial Port StatusSerial Port Security StateSerial Port Connector TypeSerial Port NameName serialPortStatus Object ID 1.3.6.1.4.1.674.10

Strany 170 - 172 Power Group

Port Group 253Serial Port Maximum SpeedSerial Port Capabilities UniqueSerial Port Base I/O AddressSerial Port IRQ LevelName serialPortMaximumSpeedObje

Strany 171 - AC Power Cord Table

254 Port GroupUniversal Serial Bus (USB) Port TableUSB Port Table EntryUSB Port Chassis IndexUSB Port IndexName uSBPortTableObject ID 1.3.6.1.4.1.674.

Strany 172 - 174 Power Group

Port Group 255USB Port State CapabilitiesUSB Port State SettingsUSB Port StatusUSB Port Security StateName uSBPortStateCapabilities Object ID 1.3.6.1.

Strany 173 - AC Power Cord Location Name

256 Port GroupUSB Port Connector TypeUSB Port NameUSB Port BIOS Connector TypeName uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7D

Strany 174 - Battery Table

Port Group 257Port Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Table

Strany 175 - Battery Reading

258 Port GroupTable 12-2. Keyboard Port Connector TypesVariable Name: DellKeyboardPortConnectorTypeData Type: IntegerPossible Data Values Meaning of D

Strany 176 - Power Usage Table

Port Group 259Table 12-3. Processor Port Connector TypesVariable Name: DellProcessorPortConnectorTypeData Type: IntegerPossible Data Values Meaning of

Strany 177 - Power Usage Status

260 Port GroupTable 12-4. Memory Device Port Connector TypesVariable Name: DellMemoryDevicePortConnectorTypeData Type: IntegerPossible Data Value Mean

Strany 178 - 180 Power Group

Port Group 261connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM).connectorPortTypeIsSODIMM(13)

Strany 179 - Power Usage Peak Amps

28 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYName is the exact st

Strany 180 - 182 Power Group

262 Port GroupTable 12-6. SCSI Port Connector TypesVariable Name: DellSCSIPortConnectorTypeData Type: IntegerPossible Data Values Meaning of Data Valu

Strany 181 - Power Usage Power Cap Value

Device Group 26313Device GroupThe Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and periphe

Strany 182 - Power Profile Table

264 Device GroupPointing Device TablePointing Device Table EntryPointing Device Chassis IndexPointing Device IndexName pointingDeviceTableObject ID 1.

Strany 183 - Power Profile Chassis Index

Device Group 265Pointing Device State CapabilitiesPointing Device State SettingsPointing Device StatusPointing Port Index ReferenceName pointingDevice

Strany 184 - 186 Power Group

266 Device GroupPointing Device TypePointing Device Number of ButtonsKeyboard Device TableKeyboard Device Table EntryName pointingDeviceTypeObject ID

Strany 185 - Power Group Variable Values

Device Group 267Keyboard Device Chassis IndexKeyboard Device IndexKeyboard Device State CapabilitiesKeyboard Device State SettingsName keyboardDevicec

Strany 186 - 188 Power Group

268 Device GroupKeyboard Device StatusKeyboard Port Index ReferenceKeyboard Device Type NameKeyboard Device Layout NameName keyboardDeviceStatusObject

Strany 187 - DellPowerSupplyType

Device Group 269Processor Device TableProcessor Device Table EntryProcessor Device Chassis IndexProcessor Device IndexName processorDeviceTableObject

Strany 188 - DellPowerSupplySensorState

270 Device GroupProcessor Device State CapabilitiesProcessor Device State SettingsProcessor Device StatusProcessor Port Index ReferenceName processorD

Strany 189 - DellVoltageType

Device Group 271Processor Device TypeProcessor Device Manufacturer NameProcessor Device Status StateProcessor Device FamilyName processorDeviceTypeObj

Strany 190 - DellVoltageDiscreteReading

Introduction 29FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescription is a bri

Strany 191 - DellAmperageType

272 Device GroupProcessor Device Maximum SpeedProcessor Device Current SpeedProcessor Device External Clock SpeedName processorDeviceMaximumSpeedObjec

Strany 192

Device Group 273Processor Device VoltageProcessor Device Upgrade InformationProcessor Device Version NameName processorDeviceVoltageObject ID 1.3.6.1.

Strany 193 - DellACPowerSwitchSettings

274 Device GroupProcessor Device Core CountProcessor Device Core Enabled CountProcessor Device Thread CountName processorDeviceCoreCountObject ID 1.3.

Strany 194

Device Group 275Processor Device CharacteristicsProcessor Device Extended CapabilitiesName processorDeviceCharacteristicsObject ID 1.3.6.1.4.1.674.108

Strany 195

276 Device GroupProcessor Device Extended SettingsProcessor Device Brand NameProcessor Device Model NameName processorDeviceExtendedSettingsObject ID

Strany 196

Device Group 277Processor Device Stepping NameProcessor Device Status TableProcessor Device Status Table EntryProcessor Device Status Chassis IndexNam

Strany 197

278 Device GroupProcessor Device Status IndexProcessor Device Status State CapabilitiesProcessor Device Status State SettingsProcessor Device Status S

Strany 198 - 200 Power Group

Device Group 279Processor Device Status ReadingProcessor Device Status Location NameProcessor Device Status Port Index ReferenceCache Device TableName

Strany 199 - Thermal Group

280 Device GroupCache Device Table EntryCache Device Chassis IndexCache Device IndexCache Device State CapabilitiesName cacheDeviceTableEntryObject ID

Strany 200 - 202 Thermal Group

Device Group 281Cache Device State SettingsCache Device StatusCache Device Processor Device Index ReferenceCache Device TypeName cacheDeviceStateSetti

Strany 201 - Cooling Unit Status

30 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTablesThis reference

Strany 202 - Cooling Device Table

282 Device GroupCache Device LocationCache Device Status StateCache Device External Socket NameCache Device LevelName cacheDeviceLocationObject ID 1.3

Strany 203 - Cooling Device Status

Device Group 283Cache Device Maximum SizeCache Device Current SizeCache Device SpeedCache Device Write PolicyName cacheDeviceMaximumSizeObject ID 1.3.

Strany 204 - 206 Thermal Group

284 Device GroupCache Device Is SocketedCache Device Error Checking and Correction (ECC) TypeCache Device AssociativityCache Device Supported TypeName

Strany 205

Device Group 285Cache Device Current TypeMemory Device TableMemory Device Table EntryMemory Device Chassis IndexName cacheDeviceCurrentTypeObject ID 1

Strany 206 - 208 Thermal Group

286 Device GroupMemory Device IndexMemory Device State CapabilitiesMemory Device State SettingsMemory Device StatusName memoryDeviceIndexObject ID 1.3

Strany 207 - Temperature Probe Table

Device Group 287Memory Device Memory Port Index ReferenceMemory Device TypeMemory Device Location NameName memoryDeviceMemoryPortIndexReferenceObject

Strany 208 - 210 Thermal Group

288 Device GroupMemory Device Error Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Er

Strany 209 - Temperature Probe Reading

Device Group 289Memory Device Form FactorMemory Device SetMemory Device SizeMemory Device SpeedName memoryDeviceFormFactorObject ID 1.3.6.1.4.1.674.10

Strany 210 - 212 Thermal Group

290 Device GroupMemory Device Total Bus WidthMemory Device Total Data Bus WidthMemory Device Correctable Memory Event Count NOTE: "Memory Device

Strany 211

Device Group 291Memory Device Uncorrectable Memory Event Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attrib

Strany 212 - 214 Thermal Group

Introduction 31FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYUUID Table EntryUUID

Strany 213 - Thermal Group Variable Values

292 Device GroupMemory Device Part Number NameMemory Device Serial Number NameMemory Device Asset Tag NameMemory Device Speed NameName memoryDevicePar

Strany 214 - DellCoolingDeviceSubType

Device Group 293Memory Device Mapped Address TableMemory Device Mapped Address Table EntryMemory Device Mapped Address Chassis IndexName memoryDeviceM

Strany 215 - DellTemperatureProbeType

294 Device GroupMemory Device Mapped Address IndexMemory Device Mapped Address State CapabilitiesMemory Device Mapped Address State SettingsMemory Dev

Strany 216 - 218 Thermal Group

Device Group 295Memory Device Index ReferenceMemory Device Mapped Address Row PositionMemory Device Mapped Address Interleave PositionName memoryDevic

Strany 217 - User Security Group

296 Device GroupMemory Device Mapped Address Interleave DepthMemory Device Mapped Address Starting AddressMemory Device Mapped Address Ending AddressG

Strany 218 - 220 User Security Group

Device Group 297Generic Device Table EntryGeneric Device Chassis IndexGeneric Device IndexGeneric Device State CapabilitiesName genericDeviceTableEntr

Strany 219 - User Security Request Name

298 Device GroupGeneric Device State SettingsGeneric Device StatusGeneric Device System Slot Index Reference Generic Device TypeName genericDeviceStat

Strany 220 - 222 User Security Group

Device Group 299Generic Device NamePCI Device TablePCI Device Table EntryPCI Device Chassis IndexName genericDeviceNameObject ID 1.3.6.1.4.1.674.10892

Strany 221 - Remote Flash BIOS Group

300 Device GroupPCI Device IndexPCI Device State CapabilitiesPCI Device State SettingsPCI Device StatusName pCIDeviceIndexObject ID 1.3.6.1.4.1.674.10

Strany 222 - 224 Remote Flash BIOS Group

Device Group 301PCI Device System Slot Index ReferencePCI Device Data Bus WidthPCI Device Manufacturer NamePCI Device Description NameName pCIDeviceSy

Strany 223 - Remote Flash BIOS Status

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 17What’s New in This Release . . . . . . . . . . . . . . 17Storage

Strany 224

32 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYUUID ValueReference

Strany 225

302 Device GroupPCI Device SpeedPCI Device Adapter FaultPCI Device Configuration Space TablePCI Device Configuration Space Table EntryName pCIDeviceSp

Strany 226 - 228 Remote Flash BIOS Group

Device Group 303PCI Device Configuration Space Chassis IndexPCI Device Configuration Space IndexPCI Device Configuration Space State CapabilitiesPCI D

Strany 227 - Port Group

304 Device GroupPCI Device Configuration Space StatusPCI Device Index ReferencePCI Device Configuration Space Bus NumberPCI Device Configuration Space

Strany 228 - 230 Port Group

Device Group 305PCI Device Configuration Space Function NumberPCI Device Configuration Space HeaderNetwork Device TableNetwork Device Table EntryName

Strany 229 - Pointing Port Connector Type

306 Device GroupNetwork Device Chassis IndexNetwork Device IndexNetwork Device StatusNetwork Device Connection StatusName networkDeviceChassisIndexObj

Strany 230 - Keyboard Port Table

Device Group 307Network Device Description Name Network Device Product NameNetwork Device Vendor NameNetwork Device Service NameName networkDeviceDesc

Strany 231 - Keyboard Port State Settings

308 Device GroupNetwork Device Driver Image Path NameNetwork Device Driver Version NameNetwork Device IP AddressNetwork Device IP Subnet MaskName netw

Strany 232 - 234 Port Group

Device Group 309Network Device Default Gateway IP AddressNetwork Device DHCP Server IP AddressNetwork Device Current MAC AddressNetwork Device Permane

Strany 233 - Processor Port Table

310 Device GroupNetwork Device PCI Bus NumberNetwork Device PCI Device NumberNetwork Device PCI Function NumberNetwork Device IRQName networkDevicePCI

Strany 234 - 236 Port Group

Device Group 311Network Device Base IO Port AddressNetwork Device Teaming FlagsNetwork Device TOE Capability FlagsNetwork Device TOE EnabledName netwo

Strany 235 - Processor Port Name

Introduction 33FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSection Organization

Strany 236 - Memory Device Port Table

312 Device GroupNetwork Device RDMA Capability FlagsNetwork Device RDMA EnabledNetwork Device iSCSI Capability FlagsNetwork Device iSCSI EnabledName n

Strany 237 - Memory Device Port Status

Device Group 313Managed System Services Device TableManaged System Services Device Table EntryManaged System Services Device Chassis IndexName managed

Strany 238 - 240 Port Group

314 Device GroupManaged System Services Device IndexManaged System Services Device StatusManaged System Services Device TypeName managedSystemServices

Strany 239 - Monitor Port Table

Device Group 315Managed System Services Device Storage PresentManaged System Services Device Storage SizeSD Card Unit TableSD Card Unit Table EntryNam

Strany 240 - 242 Port Group

316 Device GroupSD Card Unit Chassis IndexSD Card Unit IndexSD Card Unit State CapabilitiesSD Card Unit State SettingsIndex sdCardUnitChassisIndex, sd

Strany 241 - Monitor Port Name

Device Group 317SD Card Unit Redundancy StatusSD Card Unit Count For RedundancySD Card Unit NameDescription Defines the state settings of the SD Card

Strany 242 - 244 Port Group

318 Device GroupSD Card Unit StatusSD Card Device TableSD Card Device Table Entry SD Card Device Chassis Index Name sdCardUnitStatusObject ID 1.3.6.1.

Strany 243 - SCSI Port Security State

Device Group 319SD Card Device IndexSD Card Device StatusSD Card Device TypeSD Card Device Config CapabilitiesAccess Read-onlyName sdCardDeviceIndexOb

Strany 244 - Parallel Port Table

320 Device GroupSD Card Device Config Settings SD Card Device Location NameSD Card Device Card PresentSD Card Device Card StateAccess Read-onlyName sd

Strany 245 - Parallel Port Index

Device Group 321SD Card Device Card Storage Size SD Card Device Unit Index ReferenceAccess Read-onlyName sdCardDeviceCardStorageSizeObject ID 1.3.6.1.

Strany 246 - 248 Port Group

34 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY4BIOS Variable Value

Strany 247 - Parallel Port Name

322 Device GroupSD Card Device Card Available Storage SizeSD Card Device Card LicensedDevice Group Variable ValuesThis section includes definitions fo

Strany 248 - Serial Port Table

Device Group 323deviceTypeIsATouchPad(7) Device type is a touch pad.Table 13-2. Processor Device Status StateVariable Name: DellProcessorDeviceStatus

Strany 249 - Serial Port State Settings

324 Device GroupprocessorDisabled(256) The processor is disabledterminatorPresent(512) The terminator is PresentprocessorThrottled(1024) The processor

Strany 250 - 252 Port Group

Device Group 325Table 13-5. Processor Upgrade InformationVariable Name: DellProcessorUpgradeInformationData Type: IntegerPossible Data Values Meaning

Strany 251 - Serial Port IRQ Level

326 Device Group processorUpgradeIsBySocket939(18) Upgrade is by Socket 939.processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604.process

Strany 252 - 254 Port Group

Device Group 327deviceFamilyIs80287(8) The processor family is 80287.deviceFamilyIs80387(9) The processor family is 80387.deviceFamilyIs80487(10) The

Strany 253 - USB Port Security State

328 Device GroupdeviceFamilyIsK6-2Plus(31) The processor family is K6-2+.deviceFamilyIsPowerPC(32) The processor family is Power PC.deviceFamilyIsPowe

Strany 254 - 256 Port Group

Device Group 329deviceFamilyIsAMDTurionIIUltraDualMobileM(56)The processor family is AMD Turion II Ultra Dual-Core Mobile M Processor Family.deviceFam

Strany 255 - Port Group Variable Values

330 Device GroupdeviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi.deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSP

Strany 256 - DellKeyboardPortConnectorType

Device Group 331deviceFamilyIsAMDAthlon64X2DualCore(136)The processor family is AMD Athlon 64 X2 Dual-Core.deviceFamilyIsAMDTurion64X2Mobile(137)The p

Strany 257

Introduction 35FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFor each MIB group t

Strany 258 - 260 Port Group

332 Device GroupdeviceFamilyIsDualCoreIntelXeon3000(162)The processor family is Dual-Core Intel Xeon processor 3000 Series.deviceFamilyIsQuadCoreIntel

Strany 259 - DellMonitorPortConnectorType

Device Group 333deviceFamilyIsM2(177) The processor family is M2.deviceFamilyIsIntelPentium4HT (179)The processor family is Intel Pentium 4 HT process

Strany 260 - DellSCSIPortConnectorType

334 Device GroupdeviceFamilyIsIntelCore2ExtremeMobile(195)The processor family is Intel Core2 Extreme mobile processor.deviceFamilyIsIntelCore2DuoMobi

Strany 261 - Device Group

Device Group 335deviceFamilyIsDualCoreIntelXeon3xxx(215)The processor family is Dual-Core Intel Xeon processor 3xxx Series.deviceFamilyIsQuadCoreIntel

Strany 262 - Pointing Device Table

336 Device GroupdeviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom II.deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon

Strany 263 - Pointing Port Index Reference

Device Group 337Table 13-8. Cache Device LevelVariable Name: DellCacheDeviceLevelData Type: IntegerPossible Data Values Meaning of Data ValuedeviceLev

Strany 264 - Keyboard Device Table

338 Device GroupTable 13-10. Cache Device Status StateVariable Name: DellCacheDeviceStatusStateData Type: IntegerPossible Data Values Meaning of Data

Strany 265 - Keyboard Device Index

Device Group 339deviceAssociativityIsUnknown(2) Device associativity is unknown.deviceAssociativityIsDirectMapped(3) Device is direct mapped.deviceAss

Strany 266 - 268 Device Group

340 Device GroupTable 13-13. Cache Device LocationVariable Name: DellCacheDeviceLocationData Type: IntegerPossible Data Values Meaning of Data Valuede

Strany 267 - Processor Device Table

Device Group 341deviceFormFactorIsUnknown(2) Device form factor is unknown.deviceFormFactorIsSIMM(3) Device form factor is SIMM.deviceFormFactorIsSIP(

Strany 268 - 270 Device Group

36 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSNMP Management Info

Strany 269 - Processor Device Family

342 Device GroupdeviceTypeIsVRAM(5) Device type is VRAM.deviceTypeIsSRAM(6) Device type is SRAM.deviceTypeIsRAM(7) Device type is RAM.deviceTypeIsROM(

Strany 270 - 272 Device Group

Device Group 343Table 13-17. Memory Device Type DetailsVariable Name: DellMemoryDeviceTypeDetailsData Type: IntegerPossible Data Values Meaning of Dat

Strany 271 - Processor Device Version Name

344 Device GroupTable 13-18. Generic Device TypeVariable Name: DellGenericDeviceTypeData Type: IntegerPossible Data Values Meaning of Data Valuedevice

Strany 272 - 274 Device Group

Device Group 345eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory Event logging for memory device has been disabled.deviceDisabledBySpareAct

Strany 273

346 Device GroupTable 13-21. Network Device Teaming FlagsVariable Name: DellNetworkDeviceTeamingFlagsData Type: IntegerNOTE: These values are bit fiel

Strany 274 - 276 Device Group

Device Group 347Table 13-23. Network Device RDMA Capability FlagsVariable Name: DellNetworkDeviceRDMACapabilityFlagsData Type: IntegerNOTE: These valu

Strany 275 - Processor Device Status Table

348 Device GroupTable 13-25. Managed System Services Device TypeTable 13-26. SD Card Device TypeTable 13-27. SD Card Device Config CapabilitiesVariabl

Strany 276 - 278 Device Group

Device Group 349Table 13-28. SD Card Device Config SettingsTable 13-29. SD Card Device Card StateTable 13-30. SD Card Device Card LicensedVariable Nam

Strany 277 - Cache Device Table

350 Device Grouplicensed(1) SD card is licensed by system vendor.ipmiReady(2) Device is IPMI ready.fullReady(4) Device is full ready.offline(8) Device

Strany 278 - 280 Device Group

Slot Group 35114Slot GroupThe Slot Group provides information about the types of slots that your system supports. This management information base (MI

Strany 279 - Cache Device Type

Introduction 37FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYIn the preceding exa

Strany 280 - 282 Device Group

352 Slot GroupSystem Slot Chassis IndexSystem Slot IndexSystem Slot State Capabilities Unique System Slot State Settings UniqueName systemSlotchassisI

Strany 281 - Cache Device Write Policy

Slot Group 353System Slot StatusSystem Slot Current UsageSystem Slot TypeSystem Slot External Slot NameName systemSlotStatusObject ID 1.3.6.1.4.1.674.

Strany 282 - 284 Device Group

354 Slot GroupSystem Slot LengthSystem Slot Slot IDSystem Slot CategorySystem Slot Hot-Plug Bus WidthName systemSlotLengthObject ID 1.3.6.1.4.1.674.10

Strany 283 - Memory Device Table

Slot Group 355System Slot Hot-Plug Slot SpeedSystem Slot Hot-Plug Adapter SpeedSystem Slot Variable ValuesThis section includes definitions for server

Strany 284 - 286 Device Group

356 Slot GroupsystemSlotHotPlugCanSignalAttention(8)The system slot attention state (and corresponding LED) can be set.systemSlotHotPlugCanSignalPower

Strany 285 - Memory Device Location Name

Slot Group 357Table 14-2. System Slot State SettingsVariable Name: DellSystemSlotStateSettingsData Type: IntegerPossible Data Values Meaning of Data V

Strany 286 - 288 Device Group

358 Slot GroupsystemSlotSupportsCard16(1024) The system slot supports PC Card-16.systemSlotSupportsCardBus(2048) The system slot supports CardBus.syst

Strany 287 - Memory Device Speed

Slot Group 359Table 14-3. System Slot TypeVariable Name: DellSystemSlotTypeData Type: IntegerPossible Data Values Meaning of Data ValuesystemSlotIsOth

Strany 288 - 290 Device Group

360 Slot GroupsystemSlotIsPC98C20(18) The system slot is a PC-98/C20.systemSlotIsPC98C24(19) The system slot is a PC-98/C24.systemSlotIsPC98E(20) The

Strany 289 - Memory Device Failure Modes

Slot Group 361systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4.systemSlotIsPCIExpressGen2X8(175) The system slot type is

Strany 290 - 292 Device Group

38 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYManagement ActionsMa

Strany 291

362 Slot GroupTable 14-6. System Slot CategoryVariable Name: DellSystemSlotCategoryData Type: IntegerPossible Data Values Meaning of Data ValuesystemS

Strany 292 - 294 Device Group

Slot Group 363 NOTE: System slot bus width of type n bits are for parallel buses such as PCI. NOTE: System slot bus width of type nx or xn are for se

Strany 293 - Memory Device Index Reference

364 Slot Groupbook.book Page 364 Wednesday, March 6, 2013 12:37 AM

Strany 294 - Generic Device Table

Memory Group 36515Memory GroupThe Memory Group provides information about the physical memory in your system. Variables in this group include error co

Strany 295 - Generic Device Index

366 Memory GroupThe following object sets up the Physical Memory Array Table:Physical Memory Array Table EntryPhysical Memory Array Chassis IndexPhysi

Strany 296 - 298 Device Group

Memory Group 367Physical Memory Array State CapabilitiesPhysical Memory Array State SettingsPhysical Memory Array StatusPhysical Memory Array UseName

Strany 297 - PCI Device Table

368 Memory GroupPhysical Memory Array Error Checking and Correcting (ECC) TypePhysical Memory Array LocationPhysical Memory Array Maximum SizePhysical

Strany 298 - 300 Device Group

Memory Group 369Physical Memory Array In Use Number Sockets Physical Memory Array ECC Error Nonrecoverable ThresholdPhysical Memory Array ECC Error Cr

Strany 299 - PCI Device Description Name

370 Memory GroupPhysical Memory Array Redundant Memory Unit Index ReferencePhysical Memory Array Mapped TableThe physical memory array is divided into

Strany 300 - 302 Device Group

Memory Group 371Physical Memory Array Mapped Chassis IndexPhysical Memory Array Mapped IndexPhysical Memory Array Mapped State CapabilitiesPhysical Me

Strany 301 - DellObjectRange

Introduction 39FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFor a list of traps

Strany 302 - Read-only

372 Memory GroupPhysical Memory Array Mapped StatusPhysical Memory Array Index ReferencePhysical Memory Array Mapped Starting AddressPhysical Memory A

Strany 303 - Network Device Table

Memory Group 373Physical Memory Array Mapped Partition WidthPhysical Memory Configuration TableThis table defines how the physical memory of a system

Strany 304 - 306 Device Group

374 Memory GroupPhysical Memory Configuration Chassis IndexPhysical Memory Configuration IndexPhysical Memory Configuration State CapabilitiesPhysical

Strany 305 - Network Device Service Name

Memory Group 375Physical Memory Configuration StatusPhysical Memory Configuration Redundant CapabilitiesPhysical Memory Configuration Redundant Settin

Strany 306 - 308 Device Group

376 Memory GroupPhysical Memory Configuration MOM SettingsPhysical Memory Logging TableThis table defines the conditions for logging system memory eve

Strany 307

Memory Group 377Physical Memory Logging Chassis IndexPhysical Memory Logging IndexPhysical Memory Logging CapabilitiesPhysical Memory Logging Settings

Strany 308 - 310 Device Group

378 Memory GroupPhysical Memory Logging StatusRedundant Memory Unit TableThis table reports the status of redundant memory within a particular system

Strany 309 - Network Device TOE Enabled

Memory Group 379Redundant Memory Unit Table EntryRedundant Memory Unit Chassis IndexRedundant Memory Unit IndexRedundant Memory Unit State Capabilitie

Strany 310 - 312 Device Group

380 Memory GroupRedundant Memory Unit State SettingsRedundant Memory Unit Redundancy StatusRedundant Memory Unit NameRedundant Memory Unit StatusName

Strany 311

Memory Group 381Physical Memory Card TableThis table defines the name of the memory card, the total number of device slots present on the memory card,

Strany 312 - 314 Device Group

40 IntroductionFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYbook.book Page 40

Strany 313 - SD Card Unit Table

382 Memory GroupPhysical Memory Card IndexPhysical Memory Card State CapabilitiesPhysical Memory Card State SettingsPhysical Memory Card StatusName ph

Strany 314 - 316 Device Group

Memory Group 383Physical Memory Card NamePhysical Memory Card Total Number SocketsPhysical Memory Card In Use Number SocketsName physicalMemoryCardNam

Strany 315 - SD Card Unit Name

384 Memory GroupPhysical Memory Card Physical Memory Array Index ReferenceMemory Group Variable ValuesThis section includes definitions for server adm

Strany 316 - SD Card Device Table

Memory Group 385memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option

Strany 317 - SD Card Device Type

386 Memory GroupTable 15-2. Physical Memory Array ECC Type DefinitionsVariable Name: DellPhysicalMemoryArrayECCTypeData Type: IntegerPossible Data Val

Strany 318 - 320 Device Group

Memory Group 387Table 15-4. Physical Memory Configuration State SettingsVariable Name: DellPhysicalMemoryConfigStateSettings Data Type: IntegerPossibl

Strany 319

388 Memory GroupTable 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettingsData Type: Intege

Strany 320 - Device Group Variable Values

Memory Group 389Table 15-8. Physical Memory Logging SettingsVariable Name: DellPhysicalMemoryLoggingSettingsData Type: IntegerPossible Data Values Mea

Strany 321

390 Memory Groupbook.book Page 390 Wednesday, March 6, 2013 12:37 AM

Strany 322

BIOS Setup Control Group 39116BIOS Setup Control GroupBasic Input/Output System (BIOS) Setup Control Group variables provide information about the fun

Strany 323

Instrumentation MIB Version Group 412Instrumentation MIB Version GroupThe Instrumentation Management Information Base (MIB) Version Group defines the

Strany 324 - DellProcessorDeviceFamily

392 BIOS Setup Control GroupBIOS Setup Control Table EntryBIOS Setup Control Chassis IndexBIOS Setup Control (BSUC) Pointing Device Control Capabiliti

Strany 325

BIOS Setup Control Group 393BIOS Setup Control Pointing Device Control Status BIOS Setup Control Pointing Device Control NameBIOS Setup Control Numeri

Strany 326 - 328 Device Group

394 BIOS Setup Control GroupBIOS Setup Control Numeric Lock Control StatusBIOS Setup Control Numeric Lock Control NameBIOS Setup Control Processor Ser

Strany 327

BIOS Setup Control Group 395BIOS Setup Control Processor Serial Number Control StatusBIOS Setup Control Processor Serial Number Control NameBIOS Setup

Strany 328 - 330 Device Group

396 BIOS Setup Control GroupBIOS Setup Control Speaker Control StatusBIOS Setup Control Speaker Control NameBIOS Setup Control NIF Wakeup on LAN Contr

Strany 329

BIOS Setup Control Group 397BIOS Setup Control NIF Wakeup on LAN Control StatusBIOS Setup Control NIF Wakeup on LAN Control NameBIOS Setup Control Boo

Strany 330 - 332 Device Group

398 BIOS Setup Control GroupBIOS Setup Control Boot Sequence Control StatusBIOS Setup Control Boot Sequence Control NameBIOS Setup Control Administrat

Strany 331

BIOS Setup Control Group 399BIOS Setup Control Administrator Password Control Settings UniqueBIOS Setup Control Administrator Password Control StatusB

Strany 332 - 334 Device Group

400 BIOS Setup Control GroupBIOS Setup Control User Password Control Capabilities UniqueBIOS Setup Control User Password Control Settings UniqueBIOS S

Strany 333

BIOS Setup Control Group 401BIOS Setup Control User Password New Password NameBIOS Setup Control TPM Security Control CapabilitiesBIOS Setup Control T

Strany 334 - DellCacheDeviceType

4 ContentsSNMP Traps . . . . . . . . . . . . . . . . . . . . 382 Instrumentation MIB Version Group . . . . 41Management Information Base Major Ver

Strany 335 - DellCacheDeviceWritePolicy

42 Instrumentation MIB Version GroupManagement Information Base Minor Version NumberManagement Information Base Maintenance Version NumberName mIBMino

Strany 336

402 BIOS Setup Control GroupBIOS Setup Control TPM Security Control NameSCSI Control TableSCSI Control Table EntrySCSI Control Chassis IndexName bSUCt

Strany 337 - DellCacheDeviceAssociativity

BIOS Setup Control Group 403SCSI Control IndexSCSI Control CapabilitiesSCSI Control SettingsSCSI Control StatusName sCSIControlIndexObject ID 1.3.6.1.

Strany 338

404 BIOS Setup Control GroupSCSI Control NameParallel Port Control TableParallel Port Control Table EntryParallel Port Control Chassis Index Name sCSI

Strany 339 - DellMemoryDeviceFormFactor

BIOS Setup Control Group 405Parallel Port Control IndexParallel Port Control Capabilities UniqueParallel Port Control Settings UniqueParallel Port Con

Strany 340 - 342 Device Group

406 BIOS Setup Control GroupParallel Port Control NameParallel Port Control Mode Capabilities UniqueParallel Port Control Mode Settings UniqueSerial P

Strany 341 - DellMemoryDeviceTypeDetails

BIOS Setup Control Group 407Serial Port Control Table EntrySerial Port Control Chassis IndexSerial Port Control IndexSerial Port Control Capabilities

Strany 342

408 BIOS Setup Control GroupSerial Port Control Settings UniqueSerial Port Control StatusSerial Port Control NameUSB Control TableThese objects enable

Strany 343

BIOS Setup Control Group 409USB Control Table EntryUSB Control Chassis IndexUSB Control IndexUSB Control CapabilitiesName usbControlTableEntryObject I

Strany 344

410 BIOS Setup Control GroupUSB Control SettingsUSB Control StatusUSB Control NameIDE Control TableThese objects enable you to track the attributes of

Strany 345

BIOS Setup Control Group 411IDE Control Table EntryIDE Control Chassis IndexIDE Control IndexIDE Control Capabilities UniqueName ideControlTableEntry

Strany 346

Systems Management Software Group 433Systems Management Software GroupThe Systems Management Software Group allows users to see information about the

Strany 347

412 BIOS Setup Control GroupIDE Control Settings UniqueIDE Control StatusIDE Control NameDiskette Control TableName ideControlSettingsUniqueObject ID

Strany 348 - 350 Device Group

BIOS Setup Control Group 413Diskette Control Table EntryDiskette Control Chassis IndexDiskette Control IndexDiskette Control Capabilities UniqueName d

Strany 349 - Slot Group

414 BIOS Setup Control GroupDiskette Control Settings UniqueDiskette Control StatusDiskette Control NameNetwork Interface Control TableThese MIB objec

Strany 350 - 352 Slot Group

BIOS Setup Control Group 415Network Interface Control Table EntryNetwork Interface Control Chassis IndexNetwork Interface Control IndexName networkInt

Strany 351 - System Slot Type

416 BIOS Setup Control GroupNetwork Interface Control Capabilities UniqueNetwork Interface Control Settings UniqueNetwork Interface Control StatusNetw

Strany 352 - 354 Slot Group

BIOS Setup Control Group 417BIOS Setting TableThese MIB objects enable you to track the BIOS settings for your system.NOTE: These MIB objects are supp

Strany 353 - System Slot Variable Values

418 BIOS Setup Control GroupBIOS Setting NameBIOS Setting Display NameBIOS Setting Value TypeBIOS Setting Current ValueDescription Defines the index (

Strany 354 - 356 Slot Group

BIOS Setup Control Group 419BIOS Setting Pending ValueBIOS Setting Default ValueBIOS Setting Possible ValuesBIOS Setting Display Order Syntax DisplayS

Strany 355 - DellSystemSlotStateSettings

420 BIOS Setup Control GroupBIOS Setting Group Display Name BIOS Setting FQDDBIOS Group Variable ValuesThis section includes definitions for server ad

Strany 356 - 358 Slot Group

BIOS Setup Control Group 421highCapable(16) Setup BIOS can set the speaker volume to high. allVolumeCapable(30) Setup BIOS can set the speaker volume

Strany 357 - DellSystemSlotType

44 Systems Management Software GroupSystems Management Software NameSystems Management Software Version Number NameSystems Management Software Build N

Strany 358 - 360 Slot Group

422 BIOS Setup Control GroupbothCapable(14) Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF.Table 16-4. NIF W

Strany 359

BIOS Setup Control Group 423bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot fro

Strany 360 - DellSystemSlotHotPlugBusWidth

424 BIOS Setup Control GrouppasswordControlJumperDisableCapable(4)Setup BIOS is capable of determining if password control can be jumper disabled. pas

Strany 361

BIOS Setup Control Group 425passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.Table 16-10

Strany 362 - 364 Slot Group

426 BIOS Setup Control GroupTable 16-12. Parallel Port Control CapabilitiesVariable Name: DellParallelPortControlCapabilitiesUniqueData Type: IntegerP

Strany 363 - Memory Group

BIOS Setup Control Group 427Table 16-14. Parallel Port Control Mode SettingsVariable Name: DellParallelPortControlModeSettingsUniqueData Type: Integer

Strany 364 - 366 Memory Group

428 BIOS Setup Control Groupcom1OrCom3CapableAndAutoConfigCapable(86)Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports. com2OrCom

Strany 365 - Physical Memory Array Use

BIOS Setup Control Group 429Table 16-17. IDE Control CapabilitiesVariable Name: DellideControlCapabilitiesUniqueData Type: IntegerPossible Data Values

Strany 366 - 368 Memory Group

430 BIOS Setup Control GroupTable 16-20. Network Interface Control SettingsVariable Name: DellNetworkInterfaceControlSettingsUniqueData Type: IntegerP

Strany 367

Local Response Agent Group 43117Local Response Agent GroupThe Local Response Agent Group provides information about various attributes of your system’

Strany 368 - 370 Memory Group

Systems Management Software Group 45Systems Management Software Supported Protocol Systems Management Software Preferred Protocol Systems Management S

Strany 369

432 Local Response Agent GroupLRA Global Settings TableLRA Global Settings Table EntryLRA Global Chassis IndexLRA Global StateName lRAGlobalSettingsTa

Strany 370 - 372 Memory Group

Local Response Agent Group 433LRA Global Settings Disable Time-out ValueLRA Global Settings Capabilities UniqueLRA Global Thermal Shutdown Capabilitie

Strany 371

434 Local Response Agent GroupLRA Action TableThe DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilitie

Strany 372 - 374 Memory Group

Local Response Agent Group 435LRA Action Table Action Number IndexName lRAActionTableActionNumberIndexObject ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2Des

Strany 373

436 Local Response Agent GroupLRA Action Table User Application NameLRA Action Table Settings UniqueLocal Response Agent Variable ValuesThis section i

Strany 374 - Physical Memory Logging Table

Local Response Agent Group 437rebootCapable(16) The LRA can reboot the system.powerCycleCapable(32) The LRA is capable of a system power cycle.powerOF

Strany 375 - Physical Memory Logging Index

438 Local Response Agent GroupenableOnFailureCapable(10) The LRA enables activation of chassis-determined action(s) when a failure condition is detect

Strany 376 - Redundant Memory Unit Table

Cost of Ownership Group 43918Cost of Ownership GroupThe Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields f

Strany 377 - Redundant Memory Unit Index

440 Cost of Ownership GroupCost of Ownership Table EntryCOO Chassis IndexCOO StateCOO Acquisition Purchase CostName cooTableEntryObject ID 1.3.6.1.4.1

Strany 378 - 380 Memory Group

Cost of Ownership Group 441COO Acquisition Waybill NumberCOO Acquisition Install Date Name COO Acquisition Purchase Order COO Acquisition Purchase Dat

Strany 379 - Physical Memory Card Table

46 Systems Management Software GroupSystems Management Software Language NameSystems Management Software Global Version NameSystems Management Softwar

Strany 380 - 382 Memory Group

442 Cost of Ownership GroupCOO Acquisition Signing Authority NameCOO Original Machine Configuration ExpensedCOO Original Machine Configuration Vendor

Strany 381 - Physical Memory Card Name

Cost of Ownership Group 443COO User Information User NameCOO Extended Warranty Start Date NameCOO Extended Warranty End Date NameCOO Extended Warranty

Strany 382 - Memory Group Variable Values

444 Cost of Ownership GroupCOO Extended Warranty Provider NameCOO Ownership CodeCOO Corporate Owner NameCOO Hazardous Waste Code NameName cooExtendedW

Strany 383

Cost of Ownership Group 445COO Deployment Date LengthCOO Deployment Duration TypeCOO Training NameCOO Outsourcing Problem Description NameName cooDepl

Strany 384 - 386 Memory Group

446 Cost of Ownership GroupCOO Outsourcing Service Fee NameCOO Outsourcing Signing Authority NameCOO Outsourcing Provider Fee NameCOO Outsourcing Prov

Strany 385

Cost of Ownership Group 447COO Insurance Company NameCOO Box Asset Tag NameCOO Box System NameCOO Box Central Processing Unit (CPU) Serial Number Name

Strany 386 - 388 Memory Group

448 Cost of Ownership GroupCOO Operating System Upgrade Type NameCOO Operating System Upgrade Patch Level NameCOO Operating System Upgrade Date COO De

Strany 387

Cost of Ownership Group 449COO Depreciation Duration TypeCOO Depreciation PercentageCOO Depreciation Method NameCOO Registration Is RegisteredName coo

Strany 388 - 390 Memory Group

450 Cost of Ownership GroupCOO Service Contract TableThe service contract table provides MIB objects that help you track the name, vendor, and type of

Strany 389 - BIOS Setup Control Group

Cost of Ownership Group 451COO Service Contract StateCOO Service Contract Was RenewedCOO Service Contract Type NameCOO Service Contract Vendor NameNam

Strany 390 - 392 BIOS Setup Control Group

Systems Management Software Group 47Systems Management Software Manufacturer NameSystems Management Software Variable ValuesThis section includes defi

Strany 391

452 Cost of Ownership GroupCOO Cost Event Log TableThe COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of

Strany 392 - 394 BIOS Setup Control Group

Cost of Ownership Group 453COO Cost Event Log StateCOO Cost Event Log DurationCOO Cost Event Log Duration TypeCOO Cost Event Log Description NameName

Strany 393 - BIOS Setup Control

454 Cost of Ownership GroupCOO Warranty TableThe COO Warranty Table objects enable you to track facts about the type and duration of the warranty for

Strany 394 - 396 BIOS Setup Control Group

Cost of Ownership Group 455COO Warranty StateCOO Warranty DurationCOO Warranty Duration TypeCOO Warranty End Date NameName cooWarrantyStateObject ID 1

Strany 395

456 Cost of Ownership GroupCOO Warranty CostCOO Lease Information TableThe COO lease information MIB objects enable you to track information about you

Strany 396 - 398 BIOS Setup Control Group

Cost of Ownership Group 457COO Lease Information IndexCOO Lease Information StateCOO Lease Information Multiple SchedulesCOO Lease Information Buyout

Strany 397

458 Cost of Ownership GroupCOO Lease Information Lease Rate FactorCOO Lease Information End Date NameCOO Lease Information Fair Market ValueCOO Lease

Strany 398 - 400 BIOS Setup Control Group

Cost of Ownership Group 459COO Schedule Number TableCOO Schedule Number Table EntryCOO Schedule Number Chassis IndexCOO Schedule Number IndexName cooS

Strany 399

460 Cost of Ownership GroupCOO Schedule Number StateCOO Schedule Number Lease Information Index ReferenceCOO Schedule Number Description NameCOO Optio

Strany 400 - SCSI Control Table

Cost of Ownership Group 461COO Options Table EntryCOO Options Chassis IndexCOO Options IndexCOO Options StateName cooOptionsTableEntryObject ID 1.3.6.

Strany 401 - SCSI Control Status

48 Systems Management Software GroupTable 3-2. Systems Management Software Feature FlagsVariable Name: SMSFeatureFlagsData Type: IntegerPossible Data

Strany 402 - Parallel Port Control Table

462 Cost of Ownership GroupCOO Options Lease Information Index ReferenceCOO Options Description NameCOO Maintenance TableCOO Maintenance Table EntryNa

Strany 403 - Parallel Port Control Status

Cost of Ownership Group 463COO Maintenance Chassis Index COO Maintenance IndexCOO Maintenance StateCOO Maintenance Start Date NameName cooMaintenancec

Strany 404 - Serial Port Control Table

464 Cost of Ownership GroupCOO Maintenance End Date NameCOO Maintenance Provider NameCOO Maintenance Restrictions NameCOO Repair TableName cooMaintena

Strany 405 - Serial Port Control Index

Cost of Ownership Group 465COO Repair Table EntryCOO Repair Chassis IndexCOO Repair IndexCOO Repair StateName cooRepairTableEntryObject ID 1.3.6.1.4.1

Strany 406 - USB Control Table

466 Cost of Ownership GroupCOO Repair CounterCOO Repair Vendor NameCOO Support Information TableCOO Support Information Table EntryName cooRepairCount

Strany 407 - USB Control Capabilities

Cost of Ownership Group 467COO Support Information Chassis IndexCOO Support Information IndexCOO Support Information StateCOO Support Information Is O

Strany 408 - IDE Control Table

468 Cost of Ownership GroupCOO Support Information TypeCOO Support Information Help Desk NameCOO Support Information Fix Type NameCOO Trouble Ticket T

Strany 409 - IDE Control Index

Cost of Ownership Group 469COO Trouble Ticket Table EntryCOO Trouble Ticket Chassis IndexCOO Trouble Ticket IndexCOO Trouble Ticket StateName cooTroub

Strany 410 - Diskette Control Table

470 Cost of Ownership GroupCOO Trouble Ticket Support Information Index ReferenceCOO Trouble Ticket Number NameCost of Ownership Variable ValuesThis s

Strany 411 - Diskette Control Index

Cost of Ownership Group 471Table 18-2. COO Hour Day Duration TypeVariable Name: DellCooHourDayDurationTypeData Type: IntegerPossible Data Values Meani

Strany 412 - 414 BIOS Setup Control Group

System State Group 494System State GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attribut

Strany 413

472 Cost of Ownership Groupbook.book Page 472 Wednesday, March 6, 2013 12:37 AM

Strany 414 - 416 BIOS Setup Control Group

Remote Access Group 47319Remote Access GroupThe Remote Access Group provides information about the remote access hardware that may be present in your

Strany 415 - BIOS Setting Table

474 Remote Access GroupRemote Access Chassis IndexRemote Access Adapter IndexRemote Access TypeRemote Access State CapabilitiesName remoteAccessChassi

Strany 416 - 418 BIOS Setup Control Group

Remote Access Group 475Remote Access State SettingsRemote Access StatusRemote Access Product Info NameRemote Access Description Info NameName remoteAc

Strany 417 - BIOS Setting Display Order

476 Remote Access GroupRemote Access Version Info NameRemote Access Local Area Network (LAN) CapabilitiesRemote Access LAN SettingsRemote Access Netwo

Strany 418 - BIOS Group Variable Values

Remote Access Group 477Remote Access NIC Static Netmask AddressRemote Access NIC Static Gateway AddressRemote Access Personal Computer Memory Card Int

Strany 419

478 Remote Access GroupRemote Access Miscellaneous Information NameRemote Access NIC Current IP AddressRemote Access NIC Current Netmask AddressRemote

Strany 420

Remote Access Group 479Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)Remote Access Remote Connect URLDRAC IIIOn

Strany 421

480 Remote Access GroupRemote Access TableThe following MIB object sets up the Remote Access Table.Remote Access Table EntryRemote Access Chassis Inde

Strany 422

Remote Access Group 481Remote Access TypeRemote Access State CapabilitiesRemote Access State SettingsRemote Access StatusName remoteAccessTypeObject I

Strany 423

50 System State GroupList 1Variables that provide rolled-up health status for all components in associated subsystem in chassis:• systemStatePowerSupp

Strany 424 - 426 BIOS Setup Control Group

482 Remote Access GroupRemote Access Product Info NameRemote Access Description Info NameRemote Access Version Info NameRemote Access Control Capabili

Strany 425

Remote Access Group 483Remote Access Control SettingsRemote Access Monitor CapabilitiesRemote Access Monitor SettingsRemote Access Local Area Network

Strany 426 - 428 BIOS Setup Control Group

484 Remote Access GroupRemote Access LAN SettingsRemote Access Host CapabilitiesRemote Access Host SettingsRemote Access Out-of-Band Simple Network Ma

Strany 427

Remote Access Group 485Remote Access Out-of-Band SNMP SettingsRemote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address

Strany 428 - 430 BIOS Setup Control Group

486 Remote Access GroupRemote Access Firmware Update IP AddressRemote Access Firmware Update Path NameRemote Access Network Interface Controller (NIC)

Strany 429 - Local Response Agent Group

Remote Access Group 487Remote Access NIC Static Gateway AddressRemote Access Personal Computer Memory Card International Association (PCMCIA) Info Nam

Strany 430 - LRA Global Settings Table

488 Remote Access GroupRemote Access NIC Current IP AddressRemote Access NIC Current Netmask AddressRemote Access NIC Current Gateway AddressName remo

Strany 431

Remote Access Group 489Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)Remote User Administration TableRemote Use

Strany 432 - LRA Action Table

490 Remote Access GroupRemote User Admin Chassis IndexRemote User Admin Adapter IndexRemote User Admin User IndexRemote User Admin State CapabilitiesN

Strany 433

Remote Access Group 491Remote User Admin State SettingsRemote User Admin StatusRemote User Admin User NameRemote User Admin User Password NameName rem

Strany 434

System State Group 51• systemStateChassisIntrusionStatusDetails• systemStateACPowerCordStatusDetails• systemStatePowerUnitStatusList• systemStateCooli

Strany 435

492 Remote Access GroupRemote User Admin User PrivilegeRemote User Admin User Privilege CapabilitiesRemote User Admin Alert Filter DRS Events MaskRemo

Strany 436

Remote Access Group 493Remote User Admin Alert Filter DRS CapabilitiesRemote User Admin Alert Filter System CapabilitiesRemote User Admin Pager Numeri

Strany 437 - Cost of Ownership Group

494 Remote Access GroupRemote User Admin Pager Numeric Hang-up DelayRemote User Admin Pager Alpha Phone Number NameRemote User Admin Pager Alpha Proto

Strany 438 - 440 Cost of Ownership Group

Remote Access Group 495Remote User Admin Pager Alpha Custom Message NameRemote User Admin Pager Alpha Modem Connect Time-outRemote User Admin Pager Al

Strany 439

496 Remote Access GroupRemote User Admin Pager Modem Init String NameRemote User Admin Pager Modem PortRemote User Admin E-Mail Address NameRemote Use

Strany 440 - 442 Cost of Ownership Group

Remote Access Group 497Remote User Admin Control CapabilitiesRemote User Admin Control SettingsRemote User Admin User TypeRemote SNMP Trap TableName r

Strany 441 - COO Extended Warranty Cost

498 Remote Access GroupRemote SNMP Trap Table EntryRemote SNMP Trap Chassis IndexRemote SNMP Trap Adapter IndexName remoteSNMPTrapTableEntryObject ID

Strany 442 - 444 Cost of Ownership Group

Remote Access Group 499Remote SNMP Trap IndexRemote SNMP Trap State CapabilitiesRemote SNMP Trap State SettingsRemote SNMP Trap StatusName remoteSNMPT

Strany 443 - COO Training Name

500 Remote Access GroupRemote SNMP Trap Destination IP AddressRemote SNMP Trap SNMP Community NameRemote SNMP Trap Filter DRS Events MaskRemote SNMP T

Strany 444 - 446 Cost of Ownership Group

Remote Access Group 501Remote SNMP Trap Filter DRS CapabilitiesRemote SNMP Trap Filter System CapabilitiesRemote SNMP Trap Control CapabilitiesRemote

Strany 445 - COO Box System Name

Contents 56 Operating System Group . . . . . . . . . . . . 123Operating System Memory Table . . . . . . . . . 1257 System Resource Group . . . . .

Strany 446 - 448 Cost of Ownership Group

52 System State GroupSystem State Chassis IndexSystem State Global System StatusSystem State Chassis StateSystem State Chassis StatusName systemStatec

Strany 447 - COO Depreciation Method Name

502 Remote Access GroupRemote Dial-Up TableRemote Dial-Up Table EntryRemote Dial-Up Chassis IndexName remoteDialUpTableObject ID 1.3.6.1.4.1.674.10892

Strany 448 - COO Service Contract Table

Remote Access Group 503Remote Dial-Up Adapter IndexRemote Dial-Up IndexRemote Dial-Up State CapabilitiesRemote Dial-Up State SettingsName remoteDialUp

Strany 449 - COO Service Contract State

504 Remote Access GroupRemote Dial-Up StatusRemote Dial-Up PPP Dial-In Base IP AddressRemote Dial-Up PPP Dial-In Idle Time-outRemote Dial-Up PPP Dial-

Strany 450 - COO Cost Event Log Table

Remote Access Group 505Remote Dial-Up Dial-Out Modem Connect Time-outRemote Dial-Up Modem Dial TypeRemote Dial-Up Modem Init String NameRemote Dial-Up

Strany 451 - COO Cost Event Log Duration

506 Remote Access GroupRemote Dial-Up Modem PortRemote User Dial-In Configuration TableRemote User Dial-In Configuration Table EntryName remoteDialUpM

Strany 452 - COO Warranty Table

Remote Access Group 507Remote User Dial-In Configuration Chassis IndexRemote User Dial-In Configuration Adapter IndexRemote User Dial-In Configuration

Strany 453 - COO Warranty End Date Name

508 Remote Access GroupRemote User Dial-In Configuration State SettingsRemote User Dial-In Configuration StatusRemote User Dial-In Configuration PPP U

Strany 454 - COO Lease Information Table

Remote Access Group 509Remote User Dial-In Configuration Callback Phone Number NameRemote Dial-Out TableRemote Dial-Out Table EntryRemote Dial-Out Cha

Strany 455 - COO Lease Information State

510 Remote Access GroupRemote Dial-Out Adapter IndexRemote Dial-Out Dial-Out IndexRemote Dial-Out State CapabilitiesRemote Dial-Out State SettingsName

Strany 456 - 458 Cost of Ownership Group

Remote Access Group 511Remote Dial-Out StatusRemote Dial-Out IP AddressRemote Dial-Out Phone Number NameRemote Dial-Out PPP UsernameName remoteDialOut

Strany 457 - COO Schedule Number Table

System State Group 53System State Power Unit State DetailsSystem State Power Unit Status RedundancySystem State Power Unit Status DetailsName systemSt

Strany 458 - COO Options Table

512 Remote Access GroupRemote Dial-Out PPP Password NameRemote Access Variable ValuesThis section includes definitions for server administrator-specif

Strany 459 - COO Options State

Remote Access Group 513logResetCapable(2) The remote access hardware can reset its integrated logs.hardResetCapable(4) The remote access hardware can

Strany 460 - COO Maintenance Table

514 Remote Access GroupdefaultConfigReset(32) The remote access hardware resets to its default settings. shutdown(64) The remote access hardware shuts

Strany 461 - COO Maintenance State

Remote Access Group 515Table 19-5. Remote Access Monitor SettingsVariable Name: DellRemoteAccessMonitorSettingsData Type: IntegerPossible Data Values

Strany 462 - COO Repair Table

516 Remote Access GroupTable 19-7. Remote Access LAN SettingsVariable Name: DellRemoteAccessLANSettingsData Type: IntegerPossible Data Values Meaning

Strany 463 - COO Repair State

Remote Access Group 517Table 19-9. Remote Access Host SettingsVariable Name: DellRemoteAccessHostSettingsData Type: IntegerPossible Data Values Meanin

Strany 464 - COO Support Information Table

518 Remote Access GroupTable 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) SettingsVariable Name: DellRemoteAccessOutOfBa

Strany 465 - COO Support Information State

Remote Access Group 519Table 19-13. Remote User Admin State SettingsVariable Name: DellRemoteUserAdminStateSettingsData Type: IntegerPossible Data Val

Strany 466 - COO Trouble Ticket Table

520 Remote Access GroupTable 19-15. Remote User Admin Control SettingsVariable Name: DellRemoteUserAdminControlSettingsData Type: IntegerPossible Data

Strany 467 - COO Trouble Ticket State

Remote Access Group 521Table 19-17. Remote User Admin Alpha Baud TypeVariable Name: DellRemoteUserAdminAlphaBaudTypeData Type: IntegerPossible Data Va

Strany 468 - DellCooOwnershipCodes

54 System State GroupSystem State Power Supply State DetailsSystem State Power Supply Status CombinedSystem State Power Supply Status DetailsName syst

Strany 469

522 Remote Access GroupTable 19-20. Remote SNMP Trap Control CapabilitiesVariable Name: DellRemoteSNMPTrapControlCapabilitiesData Type: IntegerPossibl

Strany 470 - 472 Cost of Ownership Group

Remote Access Group 523notReadyCapable(4) The dial-up functionality can be in the not ready state.dialInCapable(8) The dial-up functionality can suppo

Strany 471 - Remote Access Group

524 Remote Access GroupdialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature.dialInAuthAnyEnabled(

Strany 472 - 474 Remote Access Group

Remote Access Group 525Table 19-25. Remote User Dial-In State CapabilitiesVariable Name: DellRemoteUserDialInStateCapabilitiesData Type: IntegerPossib

Strany 473 - Remote Access Status

526 Remote Access GroupTable 19-27. Remote Dial-Out State CapabilitiesVariable Name: DellRemoteDialOutStateCapabilitiesData Type: IntegerPossible Data

Strany 474 - 476 Remote Access Group

Remote Access Group 527Table 19-28. Remote Dial-Out State SettingsVariable Name: DellRemoteDialOutStateSettingsData Type: IntegerPossible Data Values

Strany 475 - (PCMCIA) Info Name

528 Remote Access Groupbook.book Page 528 Wednesday, March 6, 2013 12:37 AM

Strany 476 - 478 Remote Access Group

Cluster Group 52920Cluster GroupClustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhan

Strany 477 - DRAC III

530 Cluster GroupCluster Chassis IndexCluster IndexCluster State CapabilitiesCluster State SettingsName clusterChassisIndexObject ID 1.3.6.1.4.1.674.1

Strany 478 - Remote Access Table

Cluster Group 531Cluster StatusCluster TypeCluster Type Description NameCluster NameName clusterStatusObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5Des

Strany 479 - Remote Access Type

System State Group 55System State Voltage State DetailsSystem State Voltage Status CombinedSystem State Voltage Status DetailsName systemStateVoltageS

Strany 480 - 482 Remote Access Group

532 Cluster GroupCluster Group Variable ValuesThis section includes definitions for Server Administrator-specific variable values used in this section

Strany 481 - Read-write

Baseboard Management Controller Group 53321Baseboard Management Controller GroupThe Baseboard Management Controller (BMC) monitors the system for crit

Strany 482 - 484 Remote Access Group

534 Baseboard Management Controller GroupBMC Table EntryBMC Chassis IndexBMC IndexBMC State CapabilitiesName bmcTableEntryObject ID 1.3.6.1.4.1.674.10

Strany 483

Baseboard Management Controller Group 535BMC State SettingsBMC StatusBMC Display NameBMC Description NameName bmcStateSettingsObject ID 1.3.6.1.4.1.67

Strany 484 - 486 Remote Access Group

536 Baseboard Management Controller GroupBMC IPMI Version NameBMC GUIDBMC TypeBMC Module NameName bmcIPMIVersionNameObject ID 1.3.6.1.4.1.674.10892.1.

Strany 485 - Info Name

Baseboard Management Controller Group 537BMC IPv4 URL Name BMC IPv6 URL Name Baseboard Management Controller Serial Interface TableName bmcIPv4URLName

Strany 486 - 488 Remote Access Group

538 Baseboard Management Controller GroupBMC Serial Interface Table EntryBMC Serial Interface Chassis IndexBMC Serial Interface BMC IndexBMC Serial In

Strany 487 - Remote User Admin Table Entry

Baseboard Management Controller Group 539BMC Serial Interface State CapabilitiesBMC Serial Interface State SettingsBMC Serial Interface StatusBMC Seri

Strany 488 - 490 Remote Access Group

540 Baseboard Management Controller GroupBMC Serial Interface Connection Mode CapabilitiesBMC Serial Interface Connection Mode SettingsBMC Serial Inte

Strany 489 - Remote User Admin User Name

Baseboard Management Controller Group 541Baseboard Management Controller LAN Interface TableBMC LAN Interface Table EntryBMC LAN Interface Chassis Ind

Strany 490 - DellUnsigned32BitRange

56 System State GroupSystem State Amperage State DetailsSystem State Amperage Status CombinedSystem State Amperage Status DetailsName systemStateAmper

Strany 491

542 Baseboard Management Controller GroupBMC LAN Interface BMC IndexBMC LAN Interface IndexBMC LAN Interface State CapabilitiesBMC LAN Interface State

Strany 492 - 494 Remote Access Group

Baseboard Management Controller Group 543BMC LAN Interface StatusBMC LAN Interface Channel NumberBMC LAN Interface IP Address SourceBMC LAN Interface

Strany 493

544 Baseboard Management Controller GroupBMC LAN Interface Subnet Mask AddressBMC LAN Interface Default Gateway AddressBMC LAN Interface MAC AddressBM

Strany 494 - 496 Remote Access Group

Baseboard Management Controller Group 545Baseboard Management Controller Group Variable ValuesThis section includes definitions for server administrat

Strany 495 - Remote SNMP Trap Table

546 Baseboard Management Controller GroupTable 21-3. BMC Serial Flow Control TypeVariable Name: DellBMCSerialFlowControlTypeData Type: IntegerPossible

Strany 496 - 498 Remote Access Group

Baseboard Management Controller Group 547Table 21-6. BMC Management Controller TypeVariable Name: DellManagementControllerTypeData Type: IntegerPossib

Strany 497 - Remote SNMP Trap Status

548 Baseboard Management Controller Groupbook.book Page 548 Wednesday, March 6, 2013 12:37 AM

Strany 498 - 500 Remote Access Group

Field Replaceable Unit Group 54922Field Replaceable Unit GroupA field replaceable unit (FRU) is a part that can be removed and replaced without having

Strany 499

550 Field Replaceable Unit GroupFRU Chassis IndexFRU IndexFRU Information StatusFRU Information State Name fruChassisIndexObject ID 1.3.6.1.4.1.674.10

Strany 500 - Remote Dial-Up Table

Field Replaceable Unit Group 551FRU Device Name FRU Manufacturer Name FRU Serial Number NameFRU Part Number NameName fruDeviceNameObject ID 1.3.6.1.4.

Strany 501 - Remote Dial-Up State Settings

System State Group 57System State Cooling Unit State DetailsSystem State Cooling Unit Status RedundancySystem State Cooling Unit State DetailsName sta

Strany 502 - 504 Remote Access Group

552 Field Replaceable Unit GroupFRU Revision NameFRU Manufacturing Date NameFRU Asset Tag NameName fruRevisionNameObject ID 1.3.6.1.4.1.674.10892.1.20

Strany 503

Field Replaceable Unit Group 553Field Replaceable Unit Group Variable ValuesThis section includes definitions for server administrator-specific variab

Strany 504 - 506 Remote Access Group

554 Field Replaceable Unit Groupbook.book Page 554 Wednesday, March 6, 2013 12:37 AM

Strany 505

Template Last Updated - 2/7/2007 Storage Management Group 555DELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY23Storage Management GroupThe Stor

Strany 506 - 508 Remote Access Group

556 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYGlobal

Strany 507 - Remote Dial-Out Table

Storage Management Group 557FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYStorag

Strany 508 - 510 Remote Access Group

558 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 509 - Remote Dial-Out PPP Username

Storage Management Group 559FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 510 - Remote Access Variable Values

560 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 511

Storage Management Group 561FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 512 - 514 Remote Access Group

58 System State GroupSystem State Cooling Device State DetailsSystem State Cooling Device Status CombinedSystem State Cooling Device Status DetailsNam

Strany 513

562 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 514 - DellRemoteAccessLANSettings

Storage Management Group 563FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYAgent

Strany 515 - DellRemoteAccessHostSettings

564 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPhysic

Strany 516 - 518 Remote Access Group

Storage Management Group 565FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY•Tempe

Strany 517

566 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 518 - 520 Remote Access Group

Storage Management Group 567FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 519

568 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 520

Storage Management Group 569FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 521 - DellRemoteDialUpStateSettings

570 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 522 - DellRemoteDialUpModemDialType

Storage Management Group 571FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 523

System State Group 59System State Temperature State DetailsSystem State Temperature Status CombinedSystem State Temperature Status DetailsName systemS

Strany 524 - 526 Remote Access Group

572 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 525

Storage Management Group 573FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 526 - 528 Remote Access Group

574 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 527 - Cluster Group

Storage Management Group 575FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 528 - 530 Cluster Group

576 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 529 - Cluster Name

Storage Management Group 577FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 530 - Cluster Group Variable Values

578 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 531

Storage Management Group 579FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 532 - BMC State Capabilities

580 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 533 - BMC Description Name

Storage Management Group 581FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 534 - BMC Module Name

60 System State GroupSystem State Memory Device State DetailsSystem State Memory Device Status CombinedSystem State Memory Device Status DetailsName s

Strany 535 - BMC IPv6 URL Name

582 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 536 - BMC Serial Interface Index

Storage Management Group 583FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 537 - BMC Serial Interface Status

584 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 538 - BMC Serial Interface Bit Rate

Storage Management Group 585FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSyntax

Strany 539 - BMC LAN Interface Table Entry

586 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 540 - BMC LAN Interface Index

Storage Management Group 587FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 541 - BMC LAN Interface IP Address

588 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 542 - BMC LAN Interface MAC Address

Storage Management Group 589FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 543 - Variable Values

590 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYContro

Strany 544

Storage Management Group 591FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYChanne

Strany 545 - DellManagementControllerType

System State Group 61System State Chassis Intrusion State DetailsSystem State Chassis Intrusion Status CombinedSystem State Chassis Intrusion Status D

Strany 546

592 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYChanne

Strany 547 - Field Replaceable Unit Group

Storage Management Group 593FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYChanne

Strany 548 - FRU Information State

594 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYChanne

Strany 549 - FRU Part Number Name

Storage Management Group 595FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYChanne

Strany 550 - FRU Asset Tag Name

596 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYName e

Strany 551 - Integer

Storage Management Group 597FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 552

598 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 553 - Storage Management Group

Storage Management Group 599FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 554 - 556 Storage Management Group

600 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 555 - Agent Vendor

Storage Management Group 601FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 556 - Global Data Group

6 ContentsCooling Device Table . . . . . . . . . . . . . . . . 204Temperature Probe Table . . . . . . . . . . . . . 209Thermal Group Variable Value

Strany 557 - Agent Get Timeout

62 System State GroupSystem State AC Power Switch State DetailsSystem State AC Power Switch Status RedundancySystem State AC Power Switch Status Detai

Strany 558 - 560 Storage Management Group

602 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 559 - Agent MIB Version

Storage Management Group 603FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 560 - 562 Storage Management Group

604 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 561 - Agent Smart Thermal Shutdown

Storage Management Group 605FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 562 - Physical Devices Group

606 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 563 - Controller Table

Storage Management Group 607FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 564 - 566 Storage Management Group

608 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 565 - Controller State

Storage Management Group 609FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 566 - 568 Storage Management Group

610 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 567 - Controller Firmware Version

Storage Management Group 611FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 568 - 570 Storage Management Group

System State Group 63System State AC Power Cord State DetailsSystem State AC Power Cord Status CombinedSystem State AC Power Cord Status DetailsName s

Strany 569 - Controller Host Port Count

612 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSyntax

Strany 570 - 572 Storage Management Group

Storage Management Group 613FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 571 - Controller C0 Channel

614 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 572 - 574 Storage Management Group

Storage Management Group 615FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 573 - Controller C1 Channel

616 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 574 - 576 Storage Management Group

Storage Management Group 617FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 575 - Controller Component Status

618 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 576 - 578 Storage Management Group

Storage Management Group 619FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 577 - Controller PCI Slot

620 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 578 - 580 Storage Management Group

Storage Management Group 621FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 579 - Controller Patrol Read Rate

64 System State GroupSystem State Redundant Memory Unit State DetailsSystem State Redundant Memory Unit Status RedundancySystem State Redundant Memory

Strany 580 - 582 Storage Management Group

622 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 581

Storage Management Group 623FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSyntax

Strany 582 - 584 Storage Management Group

624 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 583 - Access Read-only

Storage Management Group 625FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 584 - 586 Storage Management Group

626 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 585

Storage Management Group 627FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 586 - 588 Storage Management Group

628 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 587

Storage Management Group 629FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 588 - Channel Table

630 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 589 - Channel Name

Storage Management Group 631FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 590 - 592 Storage Management Group

System State Group 65System State Event Log StatusSystem State Power Unit Status CombinedSystem State Power Unit Status ListName systemStateEventLogSt

Strany 591 - Channel SCSI ID

632 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 592 - 594 Storage Management Group

Storage Management Group 633FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 593 - Enclosure Table

634 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 594 - 596 Storage Management Group

Storage Management Group 635FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Nu

Strany 595 - Enclosure Vendor

636 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Se

Strany 596 - 598 Storage Management Group

Storage Management Group 637FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Pr

Strany 597 - Enclosure Asset Name

638 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Pr

Strany 598 - 600 Storage Management Group

Storage Management Group 639FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Ro

Strany 599 - Name enclosureESM2PartNumber

640 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Ne

Strany 600 - 602 Storage Management Group

Storage Management Group 641FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Co

Strany 601 - Enclosure Alarm

66 System State GroupSystem State Cooling Unit Status CombinedSystem State Cooling Unit Status ListSystem State AC Power Switch Status CombinedName sy

Strany 602 - 604 Storage Management Group

642 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFan Co

Strany 603

Storage Management Group 643FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 604 - 606 Storage Management Group

644 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 605 - Enclosure SAS Address

Storage Management Group 645FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 606 - 608 Storage Management Group

646 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 607 - Array Disk Table

Storage Management Group 647FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 608 - 610 Storage Management Group

648 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 609

Storage Management Group 649FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYPower

Strany 610 - 612 Storage Management Group

650 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 611 - Array Disk Revision

Storage Management Group 651FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 612 - 614 Storage Management Group

System State Group 67System State AC Power Switch Status ListSystem State Redundant Memory Unit Status CombinedSystem State Redundant Memory Unit Stat

Strany 613 - Array Disk LUN ID

652 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 614 - 616 Storage Management Group

Storage Management Group 653FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 615 - Array Disk Bus Type

654 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 616 - 618 Storage Management Group

Storage Management Group 655FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 617 - Array Disk Component Status

656 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYTemper

Strany 618 - 620 Storage Management Group

Storage Management Group 657FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 619

658 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 620 - 622 Storage Management Group

Storage Management Group 659FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 621 - Name arrayDiskManufactureWeek

660 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 622 - 624 Storage Management Group

Storage Management Group 661FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 623 - Array Disk Encryption Capable

68 System State GroupSystem State Processor Device Status CombinedSystem State Processor Device Status ListSystem State Battery Status CombinedSystem

Strany 624 - 626 Storage Management Group

662 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 625 - Array Disk Driver Version

Storage Management Group 663FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYEnclos

Strany 626 - Array Disk Device Life Status

664 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 627

Storage Management Group 665FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 628 - 630 Storage Management Group

666 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 629

Storage Management Group 667FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 630 - 632 Storage Management Group

668 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 631

Storage Management Group 669FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 632 - Fan Table

670 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 633 - Fan State

Storage Management Group 671FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYBatter

Strany 634 - 636 Storage Management Group

System State Group 69System State SD Card Unit Status CombinedSystem State SD Card Unit Status ListSystem State SD Card Device Status CombinedDescript

Strany 635 - Fan Probe Maximum Critical

672 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYLogica

Strany 636 - 638 Storage Management Group

Storage Management Group 673FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 637 - Fan Component Status

674 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 638 - Fan Connection Table

Storage Management Group 675FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 639 - Fan Connection Fan Number

676 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 640

Storage Management Group 677FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 641 - Power Supply Vendor

678 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 642 - 644 Storage Management Group

Storage Management Group 679FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 643 - Power Supply Roll-Up Status

680 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 644 - 646 Storage Management Group

Storage Management Group 681FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 645 - Power Supply Connection Table

70 System State GroupSystem State SD Card Device Status ListSyntax DellStatusAccess Read-onlyName systemStateSDCardDeviceStatusListObject ID 1.3.6.1.4

Strany 646 - 648 Storage Management Group

682 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 647

Storage Management Group 683FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYSyntax

Strany 648 - 650 Storage Management Group

684 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 649 - Temperature Probe Unit

Storage Management Group 685FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 650 - 652 Storage Management Group

686 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYVirtua

Strany 651

Storage Management Group 687FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 652 - 654 Storage Management Group

688 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 653

Storage Management Group 689FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 654 - 656 Storage Management Group

690 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 655

Storage Management Group 691FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 656 - 658 Storage Management Group

Chassis Information Group 715Chassis Information GroupThe Chassis Information Group provides information about the type or types of chassis in your sy

Strany 657

692 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 658 - 660 Storage Management Group

Storage Management Group 693FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 659

694 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 660 - 662 Storage Management Group

Storage Management Group 695FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 661

696 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 662

Storage Management Group 697FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYFluid

Strany 663 - Battery State

698 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 664 - 666 Storage Management Group

Storage Management Group 699FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 665 - Battery Predicted Capacity

700 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYArray

Strany 666 - 668 Storage Management Group

Storage Management Group 701FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYDescri

Strany 667 - Battery Learn Mode

Contents 7Pointing Device Table . . . . . . . . . . . . . . . 264Keyboard Device Table . . . . . . . . . . . . . . . 266Processor Device Table . .

Strany 668 - Battery Connection Table

72 Chassis Information GroupChassis Information Table EntryChassis Index Chassis InformationChassis State CapabilitiesChassis State SettingsName chass

Strany 669

702 Storage Management GroupFILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fmDELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLYObject

Strany 670 - Logical Devices Group

Change Management Group 70324Change Management GroupThe Change Management Group lets you monitor information about the Dell devices and software that

Strany 671 - Virtual Device Disk Name

704 Change Management GroupDevice GroupThe Device Group defines information about the devices discovered on the system during an inventory scan. Ident

Strany 672 - 674 Storage Management Group

Change Management Group 705Device Component IDDevice Display StringDevice Vendor IDDevice IDName deviceComponentIDObject ID 1.3.6.1.4.1.674.10899.1.5.

Strany 673 - Virtual Disk Length in Bytes

706 Change Management GroupDevice Sub IDDevice Sub Vendor IDApplication Group NOTE: Dell updateable components such as Basic input/output system (BIO

Strany 674 - 676 Storage Management Group

Change Management Group 707Application Group TableThe following object sets up the Application Group Table.Application EntryApplication IndexApplicati

Strany 675 - Virtual Disk Layout

708 Change Management GroupApplication Component TypeApplication VersionApplication Display StringApplication Sub-Component IDName applicationComponen

Strany 676 - 678 Storage Management Group

Change Management Group 709Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating sys

Strany 677 - Virtual Disk Roll-Up Status

710 Change Management GroupOperating System Service Pack Major VersionOperating System Service Pack Minor VersionOperating System ArchitectureInventor

Strany 678 - 680 Storage Management Group

Change Management Group 711Product ID Display NameProduct ID DescriptionProduct ID VendorProduct ID VersionName productIDDisplayNameObject ID 1.3.6.1.

Strany 679 - Virtual Disk Array Disk Type

Chassis Information Group 73Chassis StatusChassis Parent Index ReferenceChassis TypeChassis NameName chassisStatusObject ID 1.3.6.1.4.1.674.10892.1.30

Strany 680 - is CacheCade

712 Change Management GroupProduct ID Build NumberName productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5Description Describes the software bu

Strany 681 - Name virtualDiskIsCacheCade

Dell Remote Access Controller Out-of-Band Group 71325Dell Remote Access Controller Out-of-Band GroupThe Dell Remote Access Controller Out-of-Band MIB

Strany 682 - Partition Entry

714 Dell Remote Access Controller Out-of-Band GroupDRsProductDescriptionDRsProductManufacturerDRsProductVersionDRsChassisServiceTagName DRsProductDesc

Strany 683 - Partition State

Dell Remote Access Controller Out-of-Band Group 715DRsProductURLDRsProductChassisAssetTagDRsProductChassisLocation DRsProductChassisNameName DrsProduc

Strany 684 - Partition Nexus ID

716 Dell Remote Access Controller Out-of-Band GroupDRsSystemServiceTagDRsProductSystemAssetTagDRsProductSystemSlotDRsProductTypeName DRsSystemServiceT

Strany 685 - Fluid Cache Table

Dell Remote Access Controller Out-of-Band Group 717DRsFirmwareVersionChassis StatusThe following MIB tables provide information on Chassis being monit

Strany 686 - 688 Storage Management Group

718 Dell Remote Access Controller Out-of-Band GroupDRsIOMCurrStatusDRsKVMCurrStatusDRsRedCurrStatus Name DRsIOMCurrStatusObject ID 1.3.6.1.4.1.674.108

Strany 687 - Fluid Cache License Type

Dell Remote Access Controller Out-of-Band Group 719DRsPowerCurrStatusDRsFanCurrStatusDRsBladeCurrStatusName DRsPowerCurrStatusObject ID 1.3.6.1.4.1.67

Strany 688 - 690 Storage Management Group

720 Dell Remote Access Controller Out-of-Band GroupDRsTempCurrStatusDRsCMCCurrStatusDRsChassisFrontPanelAmbientTemperatureName DRsTempCurrStatusObject

Strany 689 - Fluid Cache Disk

Dell Remote Access Controller Out-of-Band Group 721DRsCMAmbientTemperatureDRsCMProcessorTemperatureDRsGlobalPrevStatusName drsCMCAmbientTemperatureObj

Strany 690 - 692 Storage Management Group

74 Chassis Information GroupChassis Manufacturer NameChassis Model NameChassis Asset Tag NameChassis Service Tag NameName chassisManufacturerNameObjec

Strany 691

722 Dell Remote Access Controller Out-of-Band GroupDRsIOMPrevStatusDRsKVMPrevStatusDRsRedPrevStatusName DRsIOMPrevStatusObject ID 1.3.6.1.4.1.674.1089

Strany 692 - 694 Storage Management Group

Dell Remote Access Controller Out-of-Band Group 723DRsPowerPrevStatusDRsFanPrevStatusDRsBladePrevStatusName DRsPowerPrevStatusObject ID 1.3.6.1.4.1.67

Strany 693 - Fluid Cache Pool Table

724 Dell Remote Access Controller Out-of-Band GroupDRsTempPrevStatusDRsCMCPrevStatusDRsGlobalChangeTimeDRsIOMChangeTimeName DRsTempPrevStatusObject ID

Strany 694 - 696 Storage Management Group

Dell Remote Access Controller Out-of-Band Group 725DRsKVMChangeTimeDRsRedChangeTimeDRsPowerChangeTimeDRsFanChangeTimeName DRsKVMChangeTimeObject ID 1.

Strany 695 - Fluid Cache Pool Status

726 Dell Remote Access Controller Out-of-Band GroupDRsBladeChangeTimeDRsTempChangeTimeDRsCMCChangeTimeName DRsBladeChangeTimeObject ID 1.3.6.1.4.1.674

Strany 696

Dell Remote Access Controller Out-of-Band Group 727Chassis PowerThe following MIB tables provide information on the chassis management controller tabl

Strany 697

728 Dell Remote Access Controller Out-of-Band GroupDRsCMC PSUTableEntryCMC Power InformationThe following MIB tables provide information on the chassi

Strany 698 - 700 Storage Management Group

Dell Remote Access Controller Out-of-Band Group 729DRsIdlePowerDRsMaxPowerSpecificationDRsPowerSurplusName DRsIdlePower Object ID 1.3.6.1.4.1.674.1089

Strany 699 - Object OID Event

730 Dell Remote Access Controller Out-of-Band GroupDRsKWhCumulativeDRsKWhCumulativeTimeDRsWattsPeakUsageDRsWattsPeakTimeName DRsKWhCumulativeObject ID

Strany 700 - 702 Storage Management Group

Dell Remote Access Controller Out-of-Band Group 731DRsWattsMinUsageDRsWattsMinTimeDRsWattsResetTimeName DRsWattsMinUsageObject ID 1.3.6.1.4.1.674.1089

Strany 701 - Change Management Group

Chassis Information Group 75Chassis IDChassis ID ExtensionChassis System ClassChassis System NameName chassisIDObject ID 1.3.6.1.4.1.674.10892.1.300.1

Strany 702

732 Dell Remote Access Controller Out-of-Band GroupDRsWattsReadingDRsAmpsReadingCMC PSU Information The following MIB tables provide information on th

Strany 703 - Device ID

Dell Remote Access Controller Out-of-Band Group 733DRsPSUIndexDRsPSULocationDRsPSUMonitoringCapableDRsPSUVoltsReadingName DRsPSUIndexObject ID 1.3.6.1

Strany 704 - Application Group

734 Dell Remote Access Controller Out-of-Band GroupDRsPSUAmpsReadingDRsPSUWattsReadingChassis AlertsThe following MIB tables provide information on th

Strany 705 - Application Group Table

Dell Remote Access Controller Out-of-Band Group 735DrsCASSCurrStatusDrsCASSPrevStatusDrsCASSChangeTimeDrsCAMessageName DrsCASSCurrStatusObject ID 1.3.

Strany 706 - 708 Change Management Group

736 Dell Remote Access Controller Out-of-Band GroupLegacy AlertingThe following MIB tables provide information on the RAC legacy alerting. DRsAlertSys

Strany 707

Dell Remote Access Controller Out-of-Band Group 737DRsAlertCurrentStatusDRsAlertPreviousStatusDRsAlertDataName DRsAlertCurrentStatusObject ID 1.3.6.1.

Strany 708 - 710 Change Management Group

738 Dell Remote Access Controller Out-of-Band Groupbook.book Page 738 Wednesday, March 6, 2013 12:37 AM

Strany 709 - Product ID Version

Traps 73926TrapsThe Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event log

Strany 710 - 712 Change Management Group

740 Trapsare reserved for use only in traps. When a varbind is created for a trap variable, a zero is appended to the object ID (OID) to create the OI

Strany 711 - Product Information

Traps 741Previous StatusDataUnderstanding the Trap DescriptionTable 27-1 lists in alphabetical order each line item that may appear in the trap descri

Strany 712 - DRsChassisServiceTag

76 Chassis Information GroupChassis System Boot Date NameChassis System Date NameChassis System Location NameChassis System Primary User NameName chas

Strany 713 - DRsProductChassisName

742 TrapsAdditional details: <Additional details for the events>Specifies possible additional details about the specified device, for example:Ad

Strany 714 - DRsProductType

Traps 743Date and time of action: <Date and time>Specifies the date and time that an automatic server recovery action was performed, for example

Strany 715

744 TrapsMemory device bank location: <Bank name in chassis>Specifies the name of the memory bank in the system that generated the message, for

Strany 716 - DRsRedCurrStatus

Traps 745Understanding Trap SeverityTraps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical co

Strany 717 - DRsBladeCurrStatus

746 Traps•Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as crossing a warning threshold.•Cr

Strany 718 - DRsCMCCurrStatus

Traps 747Miscellaneous TrapsTable 27-2 lists Miscellaneous traps that inform you that certain alert systems are up and working.TrapID Description Seve

Strany 719 - DRsGlobalPrevStatus

748 TrapsHost System Reset1007 User initiated host system control actionAction requested was: <Action> Information User requested a host system

Strany 720 - DRsRedPrevStatus

Traps 749Temperature Probe TrapsTemperature probes help protect critical components by alerting the systems management console when temperatures becom

Strany 721 - DRsBladePrevStatus

750 TrapsTemperature Probe Failure1054 Temperature sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Na

Strany 722 - DRsIOMChangeTime

Traps 751Cooling Device TrapsCooling device traps monitor how well a fan is functioning.TrapID Description Severity CauseCooling Device Normal1102 Fan

Strany 723 - DRsFanChangeTime

Chassis Information Group 77Chassis System User Phone Number NameChassis Connection Status UniqueChassis Fan Control Capabilities UniqueChassis Fan Co

Strany 724 - DRsCMCChangeTime

752 TrapsCooling Device Failure1104 Fan sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of chass

Strany 725 - Chassis Power

Traps 753Voltage Probe TrapsVoltage probes monitor the number of volts across critical components.TrapID Description Severity CauseVoltage Probe Norma

Strany 726 - CMC Power Information

754 TrapsVoltage Probe Non-recoverable1155 Voltage sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location

Strany 727 - DRsPowerSurplus

Traps 755Amperage Probe TrapsAmperage probes measure the amount of current (in amperes) that is traversing critical components.TrapID Description Seve

Strany 728 - DRsWattsPeakTime

756 TrapsAmperage Probe Failure1204 Current sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of c

Strany 729 - DRsWattsResetTime

Traps 757Chassis Intrusion TrapsChassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’

Strany 730 - CMC PSU Information

758 TrapsRedundancy Unit TrapsRedundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for ex

Strany 731 - DRsPSUVoltsReading

Traps 759Redundancy Degraded1305 Redundancy degradedRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>Pr

Strany 732 - Chassis Alerts

760 TrapsPower Supply TrapsPower supply traps provide status and warning information for power supplies present in a particular chassis.TrapID Descrip

Strany 733 - DrsCAMessage

Traps 761Memory Device TrapsMemory device messages provide status and warning information for memory modules present in a particular system. Memory de

Strany 734 - Legacy Alerting

78 Chassis Information GroupChassis LED Control Capabilities UniqueChassis LED Control Settings UniqueChassis Hard-Drive (HD) Fault Clear Control Capa

Strany 735 - DRsAlertData

762 TrapsFan Enclosure TrapsSome systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures for whether foreign

Strany 736

Traps 763Fan Enclosure Removal1453 Fan enclosure removed from systemSensor location: <Location in chassis>Chassis location: <Name of chassis&

Strany 737 - Trap Variables

764 TrapsAC Power Cord TrapsThe AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and wa

Strany 738 - Current Status

Traps 765Hardware Log TrapsHardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is impl

Strany 739 - Previous Status

766 TrapsTrapID Description Severity CauseProcessor Device Status Normal1602 Processor sensor returned to a normal valueSensor Location: <Location

Strany 740 - 742 Traps

Traps 767Pluggable Device TrapsServer Administrator monitors the addition and removal of pluggable devices such as memory cards. Device traps provide

Strany 741 - Fri May 30 23:55:44 2003

768 TrapsBattery TrapsBattery traps provide status and warning information for batteries present in a system with a BMC that reports the status of bat

Strany 742 - 744 Traps

Traps 769SD Card Device TrapsOn systems where the BMC reports the status of SD card devices, the SD card device traps provide status and error informa

Strany 743 - Understanding Trap Severity

770 TrapsRAC TrapsThis section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-s

Strany 744 - Instrumentation Traps

Traps 7711002 alertDrscAuthErrorRAC Authentication failures during a time period have exceeded a thresholdMinor Error RAC login failure caused by auth

Strany 745 - Miscellaneous Traps

Chassis Information Group 79Chassis Identify Flash Control CapabilitiesChassis Identify Flash Control SettingsChassis Lock PresentChassis Host Control

Strany 746 - 748 Traps

772 Traps1006 alertDrscPowerOnThe RAC has detected a system power state change to powered-onInformation Error RAC detected a system power state change

Strany 747 - Temperature Probe Traps

Traps 7731011 alertDrscTempCriticalThe RAC Te mp e ra tu re probe has detected a failure (or critical) valueCritical Error RAC temperature probe read

Strany 748 - 750 Traps

774 Traps1016 alertDrscSELCriticalThe RAC has detected a new event in the System Event Log with Severity: CriticalCritical Error RAC detected a new sy

Strany 749 - Cooling Device Traps

Traps 775BMC TrapsThe BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and

Strany 750 - 752 Traps

776 Traps65799 Over-Temperature warning (Upper non-critical, going high) Minor65927 Over-Temperature warning Cleared Information65801 Over-Temperature

Strany 751 - Voltage Probe Traps

Traps 777487169 CPU Thermal Trip (Over Temperature Shutdown) Critical487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information487168 CPU

Strany 752 - 754 Traps

778 Traps1076996 System Event Log (SEL) Full (Logging Disabled) Critical2322176 ASR (Automatic System Recovery) Timer Expired Critical2322177 ASR (Aut

Strany 753 - Amperage Probe Traps

Traps 779book.book Page 779 Wednesday, March 6, 2013 12:37 AM

Strany 754 - 756 Traps

780 Trapsbook.book Page 780 Wednesday, March 6, 2013 12:37 AM

Strany 755 - Chassis Intrusion Traps

Storage Management Alert Reference 78127Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the

Strany 756 - Redundancy Unit Traps

80 Chassis Information GroupChassis Host Control Settings UniqueChassis Watchdog Control Capabilities UniqueChassis Watchdog Control Settings UniqueCh

Strany 757

782 Storage Management Alert ReferenceViewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to th

Strany 758 - Power Supply Traps

Storage Management Alert Reference 783The alert severity levels are as follows: SNMP Support for Storage Management Alerts By default, Storage Managem

Strany 759 - Memory Device Traps

784 Storage Management Alert ReferenceThe Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When

Strany 760 - Fan Enclosure Traps

Storage Management Alert Reference 785Viewing SNMP TrapsSNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compati

Strany 761

786 Storage Management Alert Referencebook.book Page 786 Wednesday, March 6, 2013 12:37 AM

Strany 762 - AC Power Cord Traps

iDRAC MIB28iDRAC7 MIBThe Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-MIB.txt) is the MIB supported by the Integrated Dell Rem

Strany 763 - Processor Device Status Traps

788 iDRAC7 MIBiDRAC7 Supported SNMP VersionsThe following table identifies the SNMP version(s) that are supported by iDRAC7 for the given SNMP operati

Strany 764 - 766 Traps

iDRAC7 MIB 789RAC Short NameRAC DescriptionRAC ManufacturerRAC VersionName racShortNameObject ID 1.3.6.1.4.1.674.10892.5.1.1.2.0Description This attri

Strany 765 - Pluggable Device Traps

790 iDRAC7 MIBRAC URLRAC TypeRAC Firmware VersionChassis Information GroupThe Chassis Information Group objects provide information about the modular

Strany 766 - Battery Traps

iDRAC7 MIB 791Chassis Service TagSystem Information GroupThe System Information Group objects provide information about the system in which the iDRAC

Strany 767 - SD Card Device Traps

Chassis Information Group 81Chassis Watchdog Control Expiry TimeChassis Allow Set Commands From SNMPChassis Power Button Control Capabilities UniqueCh

Strany 768 - RAC Traps

792 iDRAC7 MIBSystem Asset TagSystem Blade Slot NumberSystem Operating System NameSystem Form FactorSyntax StringTypeAccess Read-onlyName systemAssetT

Strany 769

iDRAC7 MIB 793System Data Center NameSystem Aisle NameSystem Rack NameSystem Rack SlotDescription This attribute defines the form factor of the system

Strany 770 - 772 Traps

794 iDRAC7 MIBSystem Model Name Status GroupThe Status Group objects provide status information about the system and storage.Global System StatusSyste

Strany 771

iDRAC7 MIB 795Global Storage StatusiDRAC7 TrapsThe iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entri

Strany 772 - 774 Traps

796 iDRAC7 MIBThe trap subgroups, and all the traps within each trap subgroup, are described and listed in sections following the "Trap Variables

Strany 773 - BMC Traps

iDRAC7 MIB 797Alert System Service TagAlert System FQDNAlert FQDDSystem Trap GroupThe System Trap Group contains traps that fall under the “System Hea

Strany 774 - 776 Traps

798 iDRAC7 MIBTable 28-1. Amperage Probe TrapsTable 28-2.Automatic System Recovery TrapTable 28-3. Battery TrapsTrapID Description Category SubCategor

Strany 775

iDRAC7 MIB 799Table 28-4. Processor Device Status TrapsTable 28-5. Processor Device Absent TrapTrapID Description Category SubCategory SeverityProcess

Strany 776 - 778 Traps

800 iDRAC7 MIBTable 28-6. Fan TrapsTable 28-7. Hardware Configuration TrapsTable 28-8. Memory Device TrapsTrapID Description Category SubCategory Seve

Strany 777 - Traps 779

iDRAC7 MIB 8012265 Memory device status is critical.System HealthMemory CriticalTrapID Description Category SubCategory Severitybook.book Page 801 W

Strany 778 - 780 Traps

8 Contents16 BIOS Setup Control Group . . . . . . . . . . . 391BIOS Setup Control Group Tables . . . . . . . . . . . . 391BIOS Setup Control Table .

Strany 779 - Reference

82 Chassis Information GroupChassis Reseller NameChassis Reseller Contact Information NameChassis Reseller Product NameChassis Reseller System IDSynta

Strany 780 - Alert Severity Levels

802 iDRAC7 MIBTable 28-9. NIC TrapsTable 28-10. Operation System ("OS") Event TrapsTable 28-11. PCI Device TrapsTrapID Description Category

Strany 781 - SNMP Trap Forwarding

iDRAC7 MIB 8032418 A warning event was detected for a PCI device.System HealthPCI Device MinorPCI Device Failure2417 An error was detected for a PCI d

Strany 782 - SNMP Trap Variables

804 iDRAC7 MIBTable 28-12. Physical Disk TrapsTable 28-13. BIOS POST TrapTable 28-14. Power Supply TrapsTrapID Description Category SubCategory Severi

Strany 783 - Viewing SNMP Traps

iDRAC7 MIB 805Table 28-15. Power Supply Absent TrapTable 28-16. Power Usage TrapsTable 28-17. Redundancy TrapsTrapID Description Category SubCategory

Strany 784

806 iDRAC7 MIBTable 28-18. Integrated Dual SD Module TrapsTable 28-19. Integrated Dual SD Module Absent TrapTable 28-20. Integrated Dual SD Module Red

Strany 785 - Supported Systems

iDRAC7 MIB 807Table 28-21. Security Event TrapsTable 28-22. System Event Log TrapsTable 28-23. Temperature Probe TrapsTrapID Description Category SubC

Strany 786 - RAC Information Group

808 iDRAC7 MIBTable 28-24. Temperature Statistics TrapsTable 28-25. vFlash Media Device TrapsTable 28-26. vFlash Media Device Absent TrapTrapID Descr

Strany 787 - RAC Version

iDRAC7 MIB 809Table 28-27. Voltage Probe TrapsStorage Trap GroupThe Storage Trap Group contains traps that fall under the Storage event category of iD

Strany 788

810 iDRAC7 MIBTable 28-28. Battery TrapsTable 28-29. Controller TrapsTable 28-30. Enclosure TrapsTrapID Description Category SubCategory SeverityBatte

Strany 789 - System Information Group

iDRAC7 MIB 811Storage Enclosure Failure4337 Enclosure failure. Storage Storage EnclosrCriticalTrapID Description Category SubCategory Severitybook.boo

Strany 790 - 792 iDRAC7 MIB

Chassis Information Group 83Chassis NMI Button Control Capabilities UniqueChassis NMI Button Control Settings UniqueChassis System PropertiesSyntax De

Strany 791 - System Rack Slot

812 iDRAC7 MIBTable 28-31. Fan TrapsTable 28-32. Physical Disk TrapsTable 28-33. Power Supply TrapsTrapID Description Category SubCategory SeveritySto

Strany 792 - Status Group

iDRAC7 MIB 813Table 28-34. Storage Management Status TrapsTable 28-35. Temperature Probe TrapsTrapID Description Category SubCategory SeverityStorage

Strany 793 - Global Storage Status

814 iDRAC7 MIBTable 28-36. Virtual Disk TrapUpdates Trap GroupThe Updates Trap Group contains traps that fall under the Updates event category of iDRA

Strany 794

iDRAC7 MIB 815Table 28-37. Debug TrapsTable 28-38. iDRAC IP Address Change TrapTable 28-39. License TrapsTable 28-40. System Power State Change TrapCo

Strany 795 - System Trap Group

816 iDRAC7 MIBConfiguration event category of the iDRAC7. Configuration traps are traps generated in response to events related to hardware configurat

Strany 796 - 798 iDRAC7 MIB

iDRAC7 MIB 817book.book Page 817 Wednesday, March 6, 2013 12:37 AM

Strany 797 - Processor Device Absent Trap

818 iDRAC7 MIBbook.book Page 818 Wednesday, March 6, 2013 12:37 AM

Strany 798 - 800 iDRAC7 MIB

Standard Data Type Definitions 81929Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts

Strany 799

820 Standard Data Type DefinitionsVariables with Data Types of State Capabilities and State Capabilities UniqueVariables with definitions of <varia

Strany 800 - 802 iDRAC7 MIB

Standard Data Type Definitions 821Table 29-3. Dell State SettingsVariable Name: DellStateSettingsData Type: IntegerPossible Data Values Meaning of Dat

Strany 801

84 Chassis Information GroupChassis System Revision NumberChassis System Revision NameChassis Express Service Code NameUUID TableThese objects compris

Strany 802 - 804 iDRAC7 MIB

822 Standard Data Type DefinitionsDell Status Data TypesStatus data types include DellStatus, DellStatusRedundancy, and DellStatusProbe.Table 29-5. De

Strany 803 - Redundancy Traps

Standard Data Type Definitions 823Dell DateThe DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent ba

Strany 804 - 806 iDRAC7 MIB

824 Standard Data Type DefinitionsFull Dates Full dates are defined in the ASCII format:yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where y

Strany 805 - System Event Log Traps

SNMP Sample Output 82530SNMP Sample OutputThis appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the fir

Strany 806 - 808 iDRAC7 MIB

826 SNMP Sample Output1.3.6.1.4.1.674.10892.1.100.8.0 = 'https://1.2.3.4:1311'1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US'1.3.6.1

Strany 807 - Storage Trap Group

SNMP Sample Output 8271.3.6.1.4.1.674.10892.1.200.10.1.22.1 = '\03\03\03\03\03'1.3.6.1.4.1.674.10892.1.200.10.1.23.1 = '\02\02\02\0

Strany 808 - 810 iDRAC7 MIB

828 SNMP Sample Output1.3.6.1.4.1.674.10892.1.300.10.1.9.1 = 'PowerEdge 2650'1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG&apos

Strany 809

SNMP Sample Output 8291.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 151.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 01.3.6.1.4.1.674.10892.1.300.10.1.33.1 =

Strany 810 - 812 iDRAC7 MIB

830 SNMP Sample Outputbook.book Page 830 Wednesday, March 6, 2013 12:37 AM

Strany 811

Index 831IndexNumerics1403, 7611404, 7621602, 7661603, 7661604, 7661651, 7671653, 767AApplication, 706Application Group, 706BBIOS GroupBIOS Setup Cont

Strany 812 - Audit Trap Group

Chassis Information Group 85UUID Table EntryUUID Chassis IndexUUID IndexUUID TypeAccess Not accessibleName uUIDTableEntryObject ID 1.3.6.1.4.1.674.108

Strany 813 - Configuration Trap Group

832 IndexDdata typescommon, 819state capabilities, 820state settings, 821status, 822status probe, 823status redundancy, 822Dell RAC Out-of-Band Group,

Strany 814 - 816 iDRAC7 MIB

Index 833MMemory device correction rate crossed a warning threshold, 761Memory device ECC Correctable error count crossed a warning threshold, 761Memo

Strany 815

834 IndexRemote Access GroupRemote Access Table, 480Remote SNMP Trap Table, 497Remote User Administration Tab le , 4 8 9Remote User Dial-In Configurat

Strany 816 - 818 iDRAC7 MIB

Index 835system, 740table index OID, 740traps, 746AC power cord traps, 764amperage probe traps, 755chassis intrusion traps, 757cooling device traps, 7

Strany 817 - Common Data Types

836 Indexbook.book Page 836 Wednesday, March 6, 2013 12:37 AM

Strany 818

86 Chassis Information GroupUUID ValuePOST Log TableThis section defines attributes for the power-on self-test (POST) log. When you turn on your compu

Strany 819

Chassis Information Group 87POST Log Chassis IndexPOST Log Record IndexPOST Log State Capabilities UniquePOST Log State Settings UniqueAccess Not acce

Strany 820 - Dell Status Data Types

88 Chassis Information GroupPOST Log RecordPOST Log FormatEvent Log TableEvent Log Table EntrySyntax DellStateSettingsLogUniqueAccess Read-writeName p

Strany 821 - Dell Date

Chassis Information Group 89Event Log Chassis IndexEvent Log Record IndexEvent Log State Capabilities UniqueDescription Defines the event Log Table En

Strany 822 - Full Dates

90 Chassis Information GroupEvent Log State Settings UniqueEvent Log RecordEvent Log FormatEvent Log Severity StatusName eventLogStateSettingsUniqueOb

Strany 823 - SNMP Sample Output

Chassis Information Group 91Event Log Date NameSystem BIOS TableThis table lists objects that define the system’s basic input/output system (BIOS).Sys

Strany 824

Contents 9COO Repair Table . . . . . . . . . . . . . . . . . . 464COO Support Information Table . . . . . . . . . . 466COO Trouble Ticket Table . .

Strany 825 - SNMP Sample Output 827

92 Chassis Information GroupSystem BIOS IndexSystem BIOS State CapabilitiesSystem BIOS State SettingsSystem BIOS StatusAccess Read-onlyName systemBIOS

Strany 826

Chassis Information Group 93System BIOS SizeSystem BIOS Release Date NameSystem BIOS Version NameSystem BIOS Starting AddressAccess Read-onlyName syst

Strany 827 - SNMP Sample Output 829

94 Chassis Information GroupSystem BIOS Ending AddressSystem BIOS Manufacturer NameSystem BIOS CharacteristicsDescription Defines the starting address

Strany 828 - 830 SNMP Sample Output

Chassis Information Group 95Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined

Strany 829 - Numerics

96 Chassis Information GroupSystem BIOS Characteristics Ext 1Description Bit Position Meaning if Set-------------- ------------------Bit 16Selectab

Strany 830

Chassis Information Group 97System BIOS Characteristics Ext 2Description Defines additional characteristics of the system basic input/output system (B

Strany 831 - Index 833

98 Chassis Information GroupFirmware TableFirmware Table EntryFirmware Chassis IndexFirmware IndexName firmwareTableObject ID 1.3.6.1.4.1.674.10892.1.

Strany 832

Chassis Information Group 99Firmware State CapabilitiesFirmware State CapabilitiesFirmware StatusFirmware SizeName firmwareStateCapabilitiesObject ID

Strany 833 - Index 835

100 Chassis Information GroupFirmware TypeFirmware Type NameFirmware Update CapabilitiesFirmware Date NameName firmwareTypeObject ID 1.3.6.1.4.1.674.1

Strany 834 - 836 Index

Chassis Information Group 101Firmware Version NameIntrusion TableThe following objects and attributes describe the different forms of chassis intrusio

Komentáře k této Příručce

Žádné komentáře