Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide
Introduction
Indicators, Messages, and Codes
Running the System Diagnostics
Troubleshooting Your System
Installing System Components
Installing Drives
Service-Only Parts Replacement Procedures
Getting Help
Jumpers, Switches, and Connectors
I/O Connectors
Notes, Notices, and Cautions
Abbreviations and Acronyms
For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.
Information in this document is subject to change without notice.
©2005DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, PowerVault, PowerApp, Dell OpenManage, Inspiron, Dell Precision, Dimension, OptiPlex, and Latitude are trademarks of Dell
Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation; EMC is a registered trademark of EMC Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
Initial release: April 2005
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Zobrazit stránku 0
1 2 3 4 5 6 ... 147 148

Shrnutí obsahu

Strany 1 - Abbreviations and Acronyms

Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Running the System Diagnostics Troubl

Strany 2 - System Board Jumpers

l Use Category 5 or greater wiring and connectors. l Do not exceed a cable run length (from a workstation to a hub) of 100 m (328 ft). For detaile

Strany 3 - System Board Connectors

Back to Contents Page  Running the System Diagnostics Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Using Server Administra

Strany 4 - SCSI Backplane Connectors

Click the testing option in the Main Menu window. Table3-1 provides a brief explanation of testing options. Table 3-1. SystemDiagnosticsTestingOp

Strany 5

Back to Contents Page  Troubleshooting Your System Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Safety First—For You and Y

Strany 6 -  I/O Connectors

each PCI device for specific IRQ requirements. Table4-2 lists the IRQ assignments. Table 4-2.IRQAssignmentDefaults  Troubleshooting External Co

Strany 7 - Parallel Connector

l Keyboard is not functioning properly.  Action  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics&

Strany 8 - Video Connector

l Device connected to the serial port is not operating properly.  Action  1. Turn off the system and any peripheral devices connected to the seria

Strany 9 - Integrated NIC Connectors

2. Check the appropriate indicator on the NIC connector. See "NIC Indicators" in "Indicators, Messages, and Codes." l If the li

Strany 10

c. Unhook the right end of the bezel and pull the bezel away from the system. Figure 4-2. Installing and Removing the Optional Bezel  2. Turn

Strany 11 -  Introduction

Troubleshooting a Wet System  Problem l Liquid spilled on the system. l Excessive humidity.  Action   1. Turn off the system and attached p

Strany 12 - System Status Indicators

 5. Run the system board tests in the system diagnostics. See "Running the System Diagnostics." If the tests fail, see "Getting Hel

Strany 13

Back to Contents Page  Introduction Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Other Documents You May Need Your syst

Strany 14

 Problem l Systems management software issues a fan-related error message.  Action Ensure that none of the following conditions exist: l Ambient

Strany 15 - NIC Indicator Codes

2. Turn on the system and attached peripherals. If an error messages does not appear, go to step 12.  3. Enter the System Setup program and check t

Strany 16 - System Messages

4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  5. Open the system. See "Opening the

Strany 17

 14. If possible, restore the files to the drive. If the problem persists, see "Getting Help." Troubleshooting SATA Hard Drives  Tro

Strany 18 - System Beep Codes

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics.&quo

Strany 19 - Warning Messages

Troubleshooting Expansion Cards  Problem l Error message indicates a problem with an expansion card. l Expansion card performs incorrectly or no

Strany 20 - Alert Messages

 Action   1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagno

Strany 21 - Before You Begin

Back to Contents Page  Installing System Components Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Cooling Shroud System

Strany 22

 Installing the Cooling Shroud  1. Insert the tab on the side of the cooling shroud and the release latch into the fan assembly. See Figure5-1. 

Strany 23

 13. To test the newly installed battery, see "Troubleshooting the System Battery" in "Troubleshooting Your System." Fan Assem

Strany 24

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Front-Panel Indicator

Strany 25

 8. Close the system. See "Closing the System" in "Troubleshooting Your System." PCI Fan Module The PCI fan module provides

Strany 26

 1. Open the system. See "Opening the System" in "Troubleshooting Your System."  2. Disconnect the following power supply cab

Strany 27

  1. Open the system. See "Opening the System" in "Troubleshooting Your System."  2. Remove the expansion-card retainer adja

Strany 28 - Troubleshooting a NIC

6. Replace the expansion-card retainer.  7. Close the system. See "Closing the System" in "Troubleshooting Your System." Ri

Strany 29

message stating that maximum memory has been exceeded, see "Indicators, Messages, and Codes" for more information. You can purchase memory u

Strany 30

 6. Repeat step 2 through step 5 of this procedure to install the remaining memory modules. See Table5-1 for valid memory configurations.  7. Cl

Strany 31

2. Remove the cooling shroud. See "Removing the Cooling Shroud."  3. Using a #2 Phillips screwdriver, loosen the four captive screws tha

Strany 32

 15. Rotate the release lever back down until it snaps into place, securing the processor cover.  16. Install the heat sink. a. Using a clea

Strany 33

Back to Contents Page  Installing Drives Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Optical Drive SCSI Configuration

Strany 34

2. Rotate the drive downward until it snaps into place.  3. Connect the interposer card to the optical drive. Push the plungers into the captive

Strany 35

Table 2-2. Front-Panel Indicators, Buttons, and Connectors Back-Panel Features and Indicators Figure2-2 shows the controls, indicators, and conn

Strany 36

 2. If applicable, remove the optical drive. Remove the optical drive if you are removing hard drive 0. See "Removing the Optical Drive.&quo

Strany 37

 Installing a Hard Drive   1. Align the hard-drive mounting holes with the holes in the drive carrier.  2. Using a #2 Phillips screwdriver, i

Strany 38

Back to Contents Page 

Strany 39

Back to Contents Page  Service-Only Parts Replacement Procedures Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Recommended

Strany 40

 1. Align the control panel assembly's mounting holes with the chassis mounting holes. See Figure7-1.  2. Using a #2 Phillips screwdriver,

Strany 41

System Board The system board provides interface signal routing between the system board and the two SATA hard-drive bays, the optional CD drive, an

Strany 42

 Installing the System Board Assembly   1. Unpack the new system board assembly.  2. Align the system board tray so that the tabs on the chas

Strany 43

17. Close the system. See "Closing the System" in "Troubleshooting Your System." Back to Contents Page 

Strany 44

Back to Contents Page  Getting Help Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterprise T

Strany 45 - System Fans

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Strany 46 - Removing the Back System Fan

SCSI Hard-Drive Indicator Codes If an optional SCSI RAID controller is installed in the system, two indicators on each of the hard-drive carriers

Strany 47

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Strany 48

determining which codes to use, contact a local or an international operator.  Country (City) International Access Code Country Code City Code Depart

Strany 49

Country Code: 673 Customer Service (Penang, Malaysia) 6046334949 Transaction Sales (Penang, Malaysia) 6046334955 Canada (North York, Ontario) Inte

Strany 50

Switchboard (Home/Small Business) 32875000 Switchboard Fax (Home/Small Business) 32875001 Dominica General Support toll-free:1-866-278-6821 Dominic

Strany 51

Medium Business Division 34160912 Home and Small Business Division 29693105 India Technical Support 1600338045 Sales (Large Corporate Accounts) 16

Strany 52 - Removing Memory Modules

Latin America Customer Service (Austin, Texas, U.S.A.) 512728-3619 Fax (Technical Support and Customer Service) (Austin, Texas, U.S.A.) 512728-3883

Strany 53

International Access Code: 00 Country Code: 47 Relational Customer Care 67117575 Home/Small Business Customer Care 23162298 Switchboard 67116800 Fax

Strany 54 - Installing a Processor

Customer Care 902115236 Switchboard 917229200 Fax 917229583 Sweden (Upplands Vasby) International Access Code: 00 Country Code: 46 City Code:

Strany 55 - Installing a RAC Card

Back to Contents Page  U.S.A. (Austin, Texas) International Access Code: 011 Country Code: 1 (1-877-335-5638) Employee Purchase Program (EPP) Custome

Strany 56

Power Indicator Codes The power button on the front panel controls the power input to the system's power supplies. The power indicator can prov

Strany 57

System Messages System messages appear on the screen during system boot to notify you of a possible problem with the system. Table2-7 lists the sys

Strany 58

or optical drive interface cable, or loose power cable. "Troubleshooting an Optical Drive" in "Troubleshooting Your System." Disk

Strany 59 - Front-Panel Drive Inserts

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Strany 60 - Diskette Drive

If a beep code is emitted, write down the series of beeps and then look it up in Table2-8. If you are unable to resolve the problem by looking up the

Strany 61 - 5.25-Inch Drives

Back to Contents Page  Jumpers, Switches, and Connectors Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Jumpers—A General E

Strany 62

Diagnostics Messages When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record

Strany 63

Back to Contents Page  Finding Software Solutions Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Before You Begin Troubl

Strany 64

Back to Contents Page  IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Available IRQ4 Serial port 1 (COM1 and COM3) IRQ5 Remote access

Strany 65

Back to Contents Page  Running the System Diagnostics Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Using Server Administr

Strany 66

Click the testing option in the Main Menu window. Table4-1 provides a brief explanation of testing options. Table 4-1. SystemDiagnosticsTestingOp

Strany 67

Back to Contents Page  Troubleshooting Your System Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Safety First—For You and

Strany 68 - Hot-Plug SCSI Hard Drives

any of the procedures, see "Troubleshooting External Connections."  Troubleshooting External Connections Loose or improperly connected cabl

Strany 69

 1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics." I

Strany 70

Troubleshooting a USB Device  Problem l System message indicates a problem with a USB device. l Device connected to a USB port is not operating p

Strany 71

 Action  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics.&

Strany 72

Table A-1.SystemBoardJumperSettings System Board Connectors See FigureA-3 and TableA-2 for the location and description of the system boar

Strany 73

Removing the Cover To upgrade or troubleshoot the system, remove the system cover to gain access to internal components.   1. Turn off the system an

Strany 74

The system board holds the system's control circuitry and other electronic components. The processor and memory are installed directly on the s

Strany 75

Troubleshooting a Damaged System  Problem l System was dropped or damaged.  Action   1. Open the system. See "Opening the System."

Strany 76

 Problem l No power to the system. l Power indicator on the front panel does not light.  Action  1. Run the appropriate online diagnostics test

Strany 77

Troubleshooting System Memory  Problem l Faulty memory module. l Faulty system board. l System status indicator is amber. l System beep code

Strany 78

 3. Ensure that the memory modules are populated correctly. See "General Memory Module Installation Guidelines" in "Installing System

Strany 79

 14. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  15. Run the appropriate online diagnostic

Strany 80

l Missing or corrupted tape-backup software or tape-drive device driver. l Defective SCSI controller card.  Action   1. Run the System Setup pr

Strany 81

For information about testing the controller, see the controller's documentation. If the tests fail, continue to the next step.  3. If the SCSI

Strany 82

Action  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics.&qu

Strany 83

Table A-2.SystemBoardConnectors SCSI Backplane Connectors See FigureA-4 for the location and description of the connectors on the back of th

Strany 84 - Riser Card Connectors

l Faulty hard drive. l Damaged or improperly connected hard-drive cables.  Action   1. Run the appropriate online diagnostic test. See "Us

Strany 85

 5. Open the system. See "Opening the System."  6. Ensure that the hard-drive interface cable is properly connected to the drive and t

Strany 86

Action   1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics.&

Strany 87

 5. Close the system. See "Closing the System."  6. Reconnect the system to the electrical outlet, and turn on the system and attached

Strany 88 - Integrated NIC Connector

Back to Contents Page  Installing System Components Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Cooling Shroud System

Strany 89 - Network Cable Requirements

 Installing the Cooling Shroud  1. Ensure that no tools or loose parts are left inside the system.  2. Align the anchor tabs on the cooling sh

Strany 90

 6. Compress the two release tabs on the top of the fan assembly and lift the fan assembly away from the system. See Figure6-3. Figure 6-3. Rem

Strany 91

  1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  2. Remove the bezel. See &q

Strany 92 - Front-Panel Features

Power Supply  Removing the Power Supply   1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

Strany 93 - NIC Indicators

 3. Install the cooling shroud. See "Installing the Cooling Shroud."  4. Connect the DC power cables to the following components: l

Strany 94

Disabling a Forgotten Password The system's software security features include a system password and a setup password, which are discussed in d

Strany 95

 5. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."  6. Remove the filler bracket from the expa

Strany 96

7. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.

Strany 97

 8. Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket.

Strany 98

 9. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."  10. Stand the system upright.  11. I

Strany 99

 7. Press down on the processor socket release lever, then pull the release lever upward to the fully open position. See Figure6-10.  8. Open

Strany 100

4. Set the processor lightly in the socket and ensure that the processor is level in the socket. When the processor is positioned correctly, press it

Strany 101

See "Installing an Expansion Card" for information on installing the card.  6. Connect the cable from the RAC card to connector RAC_CONN o

Strany 102 - Checking the Equipment

 10. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."  11. Reconnect the system to its elect

Strany 103 - Troubleshooting the Keyboard

Back to Contents Page  Installing Drives Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Connecting Drives Front-Panel Dr

Strany 104 - Troubleshooting the Mouse

Front-Panel Drive Inserts To help keep dust and dirt out of the system, a plastic insert in the bezel covers each empty external drive bay. Addition

Strany 105 - Troubleshooting a NIC

Back to Contents Page  I/O Connectors Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Serial Connector Parallel Connector

Strany 106 - Opening the System

 4. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Diskette Drive  Removing a Disket

Strany 107 - Closing the System

5.25-Inch Drives An optical drive is standard in the first external drive bay. An additional IDE or SCSI tape backup device can be installed in th

Strany 108 - Problem

 10. If a controller card was supplied with the drive, install the controller card in expansion slot 3, 4, or 5. See "Installing an Expansion

Strany 109

 17. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."  18. Reconnect the system to its electr

Strany 110 - Troubleshooting a Fan

7. Remove the hard-drive bay. See Figure7-5 and Figure7-6. a. Loosen the four screws that secure the drive bay to the system. b. Slide the har

Strany 111

Installing a Cabled Hard Drive  1. Unpack the drive (and controller card, if applicable), and prepare the drive for installation. For instructions,

Strany 112

Figure 7-9. Cabling Four SCSI Hard Drives to the SCSI Controller Card  6. Ensure that all cables are firmly connected and arranged so that they wi

Strany 113

 Removing a Front-Access SCSI Hard Drive (Non-Hot-Plug)  1. Turn off the system, including any attached peripherals, and disconnect the system fro

Strany 114

 6. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."  7. Reconnect the system to its electri

Strany 115

 3. Insert the hard-drive carrier into the drive bay. See Figure7-11.  4. Close the hard-drive carrier handle to lock it in place.  5. Insta

Strany 116

Serial Connector Autoconfiguration The default designation of the integrated serial connector is COM1. When you add an expansion card containing a ser

Strany 117 - Cooling Shroud

 11. Connect the power cable connector P3 to the power connector on the SCSI backplane. See Figure7-13.  12. Connect the baseboard management

Strany 118 - System Battery

Back to Contents Page  Getting Help Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterprise

Strany 119 - Fan Assembly

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Strany 120 - Power Supply

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Strany 121 - Expansion Cards

Country (City) International Access Code Country Code City Code Toll-Free Numbers Anguilla General Support toll-free:800-335-0031 Antigua and Barbuda

Strany 122 - Removing an Expansion Card

011 Customer Care (Home Sales/Small Business) toll-free:1-800-847-4096 Customer Care (med./large business, government) toll-free:1-800-326-9463 Tech

Strany 123 - System Memory

International Access Code: 990 Country Code: 358 City Code: 9 E-mail: http://support.euro.dell.com/fi/fi/emaildell/  Technical Support 0925331360

Strany 124 - Installing Memory Modules

City Code: 1 Home User Customer Care 012044014 Small Business Customer Care 012044014 U.K. Customer Care (dial within U.K. only) 08709060010 Cor

Strany 125 - Processor

Customer Care (Brussels, Belgium) 024819119 Fax (Brussels, Belgium) 024819299 Switchboard (Brussels, Belgium) 024819100 Macao Country Code: 8

Strany 126

Reception Desk Fax 5795998 Switchboard 5795999 Portugal International Access Code: 00 Country Code: 351   Website: support.euro.dell.com  E

Strany 127

PS/2-Compatible Keyboard and Mouse Connectors The PS/2-compatible keyboard and mouse cables attach to 6-pin, miniature DIN connectors. FigureB-4 il

Strany 128 -  Installing Drives

International Access Code: 00 Country Code: 41 City Code: 22 E-mail: [email protected]  E-mail for French-speaking HSB and Corpor

Strany 129 - Hard Drives

Back to Contents Page  Dell Sales toll-free:1-800-289-3355 or toll-free:1-800-879-3355 Dell Outlet Store (Dell refurbished computers) toll-free:1-

Strany 130

Back to Contents Page Dell™PowerEdge™800SystemsInstallationandTroubleshootingGuide Notes, Notices, and Cautions Abbreviations and Acronyms

Strany 131 - Installing a Hard Drive

Back to Contents Page  Jumpers, Switches, and Connectors Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Jumpers—A General Ex

Strany 132 - Back to Contents Page

System Board Connectors See FigureA-3 and TableA-2 for the location and description of the system board connectors. Figure A-3. System Board Con

Strany 133 - Control Panel Assembly

Figure A-5. PCI-X/PCIe Riser Card Connectors Disabling a Forgotten Password The system's software security features include a system passw

Strany 134 - Daughter Card

Back to Contents Page  I/O Connectors Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide I/O Connectors Serial Connector P

Strany 135 - System Board

The default designation of the integrated serial connector is COM1. When you add an expansion card containing a serial connector that has the same des

Strany 136

Figure B-5. Video Connector Pin Numbers Table B-4. Video Connector Pin Assignments USB Connector The system's USB connector supports USB-co

Strany 137

Table B-6. NIC Connector Pin Assignments Embedded Remote Access Ethernet Connector The system's optional embedded remote access (ERA) circui

Strany 138 -  Getting Help

USB Connectors The system's USB connectors support USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-com

Strany 140 - Contacting Dell

Back to Contents Page  Introduction Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Other Information You May Need Your sys

Strany 141

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™850SystemsInstallationandTroubleshootingGuide Front-Panel Features

Strany 142

Back-Panel Features Figure2-2 shows the back-panel features of the system. Figure 2-2. Back-Panel Features NIC Indicators Figure 2-3. NIC In

Strany 143

Table 2-2. NIC Indicators System Messages System messages appear on the screen to notify you of a possible problem with the system. Table2-3 lis

Strany 144

Error 8602: Auxiliary device failure. Verify that mouse and keyboard are securely attached to correct connectors. Loose or improperly connected mouse

Strany 145

Diagnostics Indicator Codes The four diagnostics indicators on the system front panel display error codes during system startup. Table2-4 lists the

Strany 146

Table 2-4.DiagnosticIndicatorCodes  Code  Causes  Corrective Action Possible processor failure. See "Troubleshooting the Microprocessor&q

Strany 147

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Strany 148

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a dis