Dell PowerEdge RAID Controller H700 Uživatelský manuál Strana 147

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 178
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 146
Troubleshooting 147
Replace Member Errors
Table 9-6 describes issues related to the Replace Member feature.
NOTE: For more information about the Replace Member features, see
"Using
Replace Member and Revertible Hot Spares" on page 35
.
Table 9-6. Replace Member Operation Errors
Issue Corrective Action
The source disk fails
during the Replace
Member operation.
If the source data is available from other disks in the virtual
disk, the rebuild begins automatically on the target disk, using
the data from the other disks.
Target disk fails If the target disk fails, the Replace Member operation aborts.
Other disks fail If the target disk fails and the Replace Member operation
aborts but the source data is still available, then the Replace
Member operation continues as Replace Member.
PERC7.2_UG.book Page 147 Thursday, March 3, 2011 2:14 PM
Zobrazit stránku 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 177 178

Komentáře k této Příručce

Žádné komentáře