l Verify that the autoloader operates correctly when properly configured and attached directly to a host
system using a cross-over cable.
l If all previous steps fail, see Contacting Dell.
IP Stack Can't Free Memory
l Check support.dell.com for PowerVault 124T firmware updates.
l Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended
actions.
l Power cycle the autoloader using the front panel power button and retry the operation.
l If all previous steps fail, see Contacting Dell.
Drive Logout/Unexpected Error
Command Flushed From Queue
Drive Manager Not In Correct
State
Drive Reporting Not Ready
l Check the Remote Management Unit autoclean Configuration settings. Insure that a valid cleaning
cartridge is located at the configured location.
l Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the
cartridge except where labels are expected to be placed.
l Try a different cleaning cartridge.
l If the operation fails with two different cleaning cartridges, see Contacting Dell.
l Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended
actions.
l Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the
cartridge except where labels are expected to be placed.
l Try to load a different piece of media.
l Power cycle the autoloader using the front panel power button and retry the operation.
l If all previous steps fail, see Contacting Dell.
Drive Communications Error
l Check support.dell.com for PowerVault 124T firmware updates.
l Check the TapeAlert log for more specific drive error information. Refer to Table 3 for recommended
actions.
l Power cycle the autoloader using the front panel power button and retry the operation.
l If all previous steps fail, see Contacting Dell.
Drive Communications Error
Loader Communication Error
Failed to Send CUP Cmd to
Drive / No Response From Drive
l Verify the firmware images for both the autoloader and drive are the most recent images located at
support.dell.com.
l Review the firmware update readme file provided with the firmware images.
Note: The recommended method for drive firmware update is through the host interface using the
DFU utility provided with the firmware images. The recommended method for loader firmware update
is through the Remote Management Unit.
l Verify all SAS cable connections between the host and autoloader.
l Verify no media in drive during update.
l Power cycle the autoloader using the front panel power button and retry the operation.
l If all previous steps fail, see Contacting Dell.
Drive Update Failed, Media
Present
Image Size in Header Too Big
Reset During Drive Update
Unexpected Reset From Drive
Unexpected Message From PSP
Personality or Version Check
Failed
Error During Write Buffer
Command
Image Processing Ended Early
Unexpected Response or Data
Received
l Verify the host backup application and device driver are at the latest supported revision at
support.dell.com.
Komentáře k této Příručce