Dell PowerEdge C5230 Uživatelský manuál Strana 89

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 146
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 88
Using the System Setup Program 89
WARN_MIRROR_
DISABLE_MINOR_
RAS_DISABLED
01h X X X X Unable to enable
Mirror mode
because ECC is
disabled. Switch to
independent
channel mode. (2)
WARN_MIRROR_
DISABLE_MINOR_
MISMATCH
02h X X X X Mismatched
DIMM pairs found
accross channels.
Switch to
independent
channel mode.
WARN_MIRROR_
DISABLE_MINOR_
MEMTEST
03h X X X X Mirror mode was
disabled due to
memory test
failure
WARN_MEM_
LIMIT
0Dh X X X X IMC memory
decode limit was
reached before all
memory could be
allocated.
WARN_INTERLEA
VE_FAILURE
0Eh Interleave mode
failure
WARN_SAD_
RULES_
EXCEEDED
01h X X X X Number of SAD
rules exeeds
WARN_TAD_RULE
S_EXCEEDED
02h NOD
E
XXXNumber of TAD
rules exeeds
WARN_RIR_RULE
S_EXCEEDED
03h NOD
E
CH X X Number of RIR
rules exeeds
WARN_TAD_OFFS
ET_NEGATIVE
04h NOD
E
X X X Negative TAD
offset
Table 2-16. MRC Warning Code
Warning Major
Code
Minor
Code
Data (DWord) Descriptions
31:16 15:0 31:24 23:16 15:8 7:0
Zobrazit stránku 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 145 146

Komentáře k této Příručce

Žádné komentáře