omconfig: Managing Components Using the Instrumentation Service 61
nicselection=nic1 | teamednic1nic2 |
dracnic
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5 is
installed.
NOTE: The option nicselection is supported only
on PowerEdge 1950, 1955, 2900, and 2950 systems.
NOTE: If there are multiple embedded NICs on
your system, you can select the NIC teaming
option to share the BMC management traffic
between them.
privilegelevel=administrator | operator
| user
administrator: Sets the maximum privilege
level that can be accepted on a LAN channel to
Administrator.
operator: Sets the maximum privilege level that
can be accepted on a LAN channel to Operator.
user: Sets the maximum privilege level that can
be accepted on a LAN channel to User.
subnet=Subnet subnet: Sets a subnet mask if you have selected
static as the IP address source for the BMC
LAN interface.
config=nic
(continued)
vlanenable=true | false true: Enables the virtual LAN identification.
false: Disables the virtual LAN identification.
vlanid=number number: Virtual LAN identification in the
range of 1 to 4094.
vlanpriority=number number: Priority of virtual LAN identification
in the range of 0 to 7.
Table 4-3. omconfig chassis bmc (continued)
name=value pair 1
config=
name=value pair 2 Description
Zobrazit stránku 60