Traps 701
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
Table 27-4. Cooling Device Traps
TrapID Description Severity Cause
Cooling Device Normal
1102 Fan sensor returned to a normal
value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Information A fan sensor reading on
the specified system
returned to a valid range
after crossing a warning
threshold. The sensor
location, chassis location,
previous state, and fan
sensor value are
provided.
Cooling Device Warning
1103 Fan sensor detected a warning value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Warning A fan sensor reading in
the specified system
exceeded a warning
threshold. The sensor
location, chassis location,
previous state, and fan
sensor value are
provided.
book.book Page 701 Tuesday, February 28, 2012 2:19 PM