Why is the Installation date showing up as 12/31/1969 for some of the firmware on the
firmware page.
In the Web Client, the installation date is showing up as 12/31/1969 for some firmware items on the firmware page for a
host. If the firmware installation date is not available, then this very old date is shown.
Resolution: If you see this old date for any firmware component, consider that the installation date is not available for it.
Versions Affected: 2.0
Why is successive Global refresh cause exception to be thrown in Recent Task window
If a customer tries to press the refresh button repeatedly, the VMware UI may throw an exception.
Resolution: User should dismiss this error and can continue on.
Version Affected: 2.0
Why is the Web client UI distorted for few of the Dell screens in IE 10
In some cases, when a popup dialog is presented, the data in the background may turn completely white and be
distorted.
Resolution: Close the dialog, the screen will return back to normal.
Version Affected: 2.0
Even if my repository has bundles for selected 11G system, why is firmware update
showing that I have no bundles for Firmware Update?
When I added a host to the connection profile in lockdown mode, the inventory kicked off but failed stating that “No
Remote Access Controller was found or Inventory is not supported on this host.” Inventory is supposed to work for a
host in lockdown mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30–minutes before
performing the next operation on the If I pick a 11G host for firmware update, the firmware update wizard will not show
any bundles even if the repository provided has bundles for that system. This will happen because the 11G host might
not configured for OMSA to send traps to OpenManage Integration.
Resolution: Ensure that the host is compliant using the host Compliance screen of OpenManage Integration .NET client.
If it is not compliant, use the fix Host Compliance to get it compliant.
Version Affected: 2.0
Why am I not seeing the OpenManage Integration Icon on the Web Client even if the
registration of the plug-in to the vCenter was successful?
Dell OpenManage Integration Plug-in icon is not displayed on the Web client unless the vCenter Web Client services are
restarted or the Box is rebooted. When a user registers the OpenManage Integration for VMware vCenter appliance, it
registers with both the .Net client and the Web client. If a user unregisters the appliance and then either reregisters the
same version or registers a new version of the appliance, it will successfully register with both clients, but the Dell icon
may not appear in the Web Client. This is due to a caching issue from VMware. To clear the issue, a user needs to
restart the Web Client Service on the vCenter Server. Only then will the plug-in appear in the UI.
Resolution: Restart the Web Client Service on the vCenter Server.
Version Affected: 2.0