Dell OpenManage Server Administrator Version 7.2 Uživatelská příručka Strana 142

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 573
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 141
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Memory power and performance management type is
Maximum Performance.
mhz1333(2)
Memory power and performance is 1333 MHz. .
mhz1067(4)
Memory power and performance is 1067 MHz.
mhz800(8)
Memory power and performance is 800 MHz.
minPower(16)
Memory power and performance management type is
Minimum Power.
Table 428. Fan Power Performance Management Type
Variable Name: DellFanPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Fan power and performance management type is
Maximum Performance.
minPower(2)
Fan power and performance management type is
Minimum Power.