Strany 1 - Dell PowerEdge R510

Technical Guide Dell Product Name Dell PowerEdge R510 Name Excellent balance of internal storage, redundancy, and value in a compact chassis

Strany 2

Dell PowerEdge R510 Technical Guide 10 PowerEdge 2950 III (Predecessor) PowerEdge R710 (Current) PowerEdge R510 (New) DIAGNOSTIC LCD LCD LED for P

Strany 3 - Table of Contents

Dell PowerEdge R510 Technical Guide 11 2 New Technologies A number of new technologies have been incorporated into the PowerEdge R510 product, in

Strany 4

Dell PowerEdge R510 Technical Guide 12 Chipset. 2.2.1 PCIe Generation 2 PCIe Gen 2 provides the next generation of I/O bandwidth to the system. PCI

Strany 5

Dell PowerEdge R510 Technical Guide 13 3 System Overview PowerEdge R510 provides a value 2S 2U server, with maximized storage capacity, high perfo

Strany 6 - Figures

Dell PowerEdge R510 Technical Guide 14 PowerEdge R510–4 drives PowerEdge R510–8 drives PowerEdge R510-12 drives Dimension (HxWxD) 3.40 x 17.19 x

Strany 7 - 1 Overview

Dell PowerEdge R510 Technical Guide 15 PowerEdge R510–4 drives PowerEdge R510–8 drives PowerEdge R510-12 drives HDD/SSD NA 2.5" (in hard dri

Strany 8

Dell PowerEdge R510 Technical Guide 16 PowerEdge R510–4 drives PowerEdge R510–8 drives PowerEdge R510-12 drives NICs/Single Port Broadcom NetXtre

Strany 9 - 1.2 Product Comparison

Dell PowerEdge R510 Technical Guide 17 PowerEdge R510–4 drives PowerEdge R510–8 drives PowerEdge R510-12 drives Linux: RHEL 4.7 ES/AS x86(DIB) RH

Strany 10

Dell PowerEdge R510 Technical Guide 18 4 Mechanical 4.1 Chassis Description PowerEdge R510 chassis is a 2U rack system. The chassis is not swappab

Strany 11 - 2.2 Sparing

Dell PowerEdge R510 Technical Guide 19 Figure 3. System Dimensions

Strany 12 - 2.2.2 DDR3 Memory Technology

Dell PowerEdge R510 Technical Guide 2 This document is for informational purposes only. Dell reserves the right to make changes without furt

Strany 13 - 3 System Overview

Dell PowerEdge R510 Technical Guide 20 4.3 Front Panel View and Features Figure 4. PowerEdge R510–4 HDD Configuration Figure 5. PowerEdge R

Strany 14

Dell PowerEdge R510 Technical Guide 21 Figure 6. PowerEdge R510–12 HDD Configuration 4.3.1 NMI Button The Non-Maskable Interrupt (NMI) button c

Strany 15

Dell PowerEdge R510 Technical Guide 22 The Power LED has two states: • Power LED is OFF: System is not operating, regardless of AC present. (Other

Strany 16

Dell PowerEdge R510 Technical Guide 23 This hierarchy dictates that connections that are lower in the hierarchy be disabled anytime a higher level

Strany 17

Dell PowerEdge R510 Technical Guide 24 4.4 Back Panel View and Features Figure 9. R510 with Non-Redundant Power Supply for PowerEdge R510-4 ONLY

Strany 18 - 4 Mechanical

Dell PowerEdge R510 Technical Guide 25 Figure 12. Redundant PSU Status lights provide indications as follows:  Not lit: AC power is not conne

Strany 19

Dell PowerEdge R510 Technical Guide 26 4.6 Internal Chassis Views Figure 15. PowerEdge R510-4: Non-Redundant PSU and the Battery Holder for PERC

Strany 20

Dell PowerEdge R510 Technical Guide 27 Figure 17. PowerEdge R510-12 Internal View (Redundant PSU with PDB and Additional Fan for PSU) Figure 1

Strany 21 - 4.3.1 NMI Button

Dell PowerEdge R510 Technical Guide 28 4.7 Rails and Cable Management ReadyRailsTM Sliding Rails for 4-post Racks support:  Toolless installat

Strany 22 - 4.3.5 USB Connectors

Dell PowerEdge R510 Technical Guide 29 4.8 Rail View Figure 19. R510 Sliding Rails without CMA Figure 20. R510 Sliding Rails with CMA

Strany 23

Dell PowerEdge R510 Technical Guide 3 Table of Contents 1 Overview ...

Strany 24

Dell PowerEdge R510 Technical Guide 30 Figure 21. R510 Static Rails Figure 22. R510 Static Rails in Rack 4.9 Fans 4.9.1 Fan module PowerEdge

Strany 25 - 4.5 Side Views and Features

Dell PowerEdge R510 Technical Guide 31 Figure 23. Fan Module for R510-4 and 8 PowerEdge R510-12 has redundant fans stacked in modules. Figure 2

Strany 26 - 4.6 Internal Chassis Views

Dell PowerEdge R510 Technical Guide 32 Figure 25. Fan Location 4.9.3 Fan Connector and Connector Locations Figure 26. Fan Connector Location

Strany 27

Dell PowerEdge R510 Technical Guide 33 4.10 Cabling Table 8. Cabling Information Chassis Controller Note PowerEdge R510-4 No Add-in RAID cont

Strany 28

Dell PowerEdge R510 Technical Guide 34 4.11.2 Hard Drive Security Hard drives are only accessible by unlocking and opening the bezel. 4.11.3 Intr

Strany 29 - 4.8 Rail View

Dell PowerEdge R510 Technical Guide 35 The PowerEdge R510-12 internal USB connectors are on the backplane as shown below. Figure 29. PowerEdge R

Strany 30 - 4.9 Fans

Dell PowerEdge R510 Technical Guide 36 5 Power, Thermal, Acoustic 5.1 Power Supplies The 4-HDD configuration includes a 480W power supply. The 8-

Strany 31

Dell PowerEdge R510 Technical Guide 37 Figure 31. Connector (8 pins) 5.2 Thermal Optimized thermal management makes PowerEdge R510 cool

Strany 32

Dell PowerEdge R510 Technical Guide 38 Table 9. Operating/Non-Operating (Storage) Requirements Operating Requirements Non-Operating Requirements

Strany 33 - 4.11 Security

Dell PowerEdge R510 Technical Guide 39 5.6 Acoustics The acoustical design of the PowerEdge R510 reflects the following:  Adherence to Dell’s hi

Strany 34 - 4.12 USB Key

Dell PowerEdge R510 Technical Guide 4 4.14 Field Replaceable Units (FRU) ...

Strany 35 - 4.13 Battery

Dell PowerEdge R510 Technical Guide 40 Table 10. Acoustics of 4-HDD Chassis Typical Configuration @ 23 ± 2 °C Operating Mode LWA-UL (Bels) LpA (d

Strany 36 - 5 Power, Thermal, Acoustic

Dell PowerEdge R510 Technical Guide 41 Definitions Standby: AC Power is connected to Power Supply Units but system is not turned on. Idle: Referenc

Strany 37 - 5.2 Thermal

Dell PowerEdge R510 Technical Guide 42 6 Processors R510 can operate in either single-processor or dual-processor mode. However, since the memory

Strany 38 - 5.5 Energy Star Compliance

Dell PowerEdge R510 Technical Guide 43 7 Memory 7.1 Overview Please carefully review this entire section Features of the PowerEdge R510 memory inc

Strany 39 - 5.6 Acoustics

Dell PowerEdge R510 Technical Guide 44 8 Chipset 8.1 Overview Introduction of the new Intel Xeon processor 5600 series includes a stepping revisio

Strany 40

Dell PowerEdge R510 Technical Guide 45 8.2.3 PCI Express* Interfaces PCI Express* Interfaces include: • Intel 5500 chipset IOH provides multiple P

Strany 41

Dell PowerEdge R510 Technical Guide 46 9 BIOS 9.1 Overview A flash resides on the SPI bus for BIOS and configuration storage. A 32 Mbit device is

Strany 42 - 6 Processors

Dell PowerEdge R510 Technical Guide 47 AC recovery staggering Power-Up Power Inventory (PSU, CPU, and DIMM mismatch checking) Support for Multiple

Strany 43 - 7.4 Sparing

Dell PowerEdge R510 Technical Guide 48 Table 15. Summary of Power Management Features Feature Type Enable/Status/ Ctrl bit location Description A

Strany 44 - 8 Chipset

Dell PowerEdge R510 Technical Guide 49 Table 16. Supported Power Profiles Static MAX Performance DBPM Disabled ( BIOS sets P-State to MAX) Memor

Strany 45

Dell PowerEdge R510 Technical Guide 5 10.2.3 PCI Card Dimensions ... 55

Strany 46 - 9 BIOS

Dell PowerEdge R510 Technical Guide 50 9.3 UEFI and ACPI For PowerEdge R510 systems, the UEFI layer does not participate in generation of the ACPI

Strany 47 - 9.2 ACPI

Dell PowerEdge R510 Technical Guide 51 Table 18. Intel 5600 Chipset P-State Projections and Turbo Mode Frequency Processor QDF# Frequency (GHz)

Strany 48

Dell PowerEdge R510 Technical Guide 52 Table 19. UEFI Summary UEFI IS UEFI IS NOT  Compliant with UEFI specification 2.1  A layer on top of t

Strany 49

Dell PowerEdge R510 Technical Guide 53 10 I/O Slots 10.1 Overview The PowerEdge R510 system provides two configurations for I/O slots:  Riser 1

Strany 50 - 9.3 UEFI and ACPI

Dell PowerEdge R510 Technical Guide 54 10.1.2 PCI Device Information • IOH port 1, 2 (PCI Express Gen2 x4) – Broadcom BCM5716 Gigabit LOM • IOH

Strany 51 - 9.5 UEFI

Dell PowerEdge R510 Technical Guide 55 Table 22. Riser 2 Slot Information Bandwidth Slot Location Height Length Slot1 (Gen2) PCIe x16 PCIe x16 F

Strany 52

Dell PowerEdge R510 Technical Guide 56 11 Storage 11.1 Overview There are two types of chassis for R510. • 4 Hard Drive Chassis: x cabled 3.5‖ HDD

Strany 53 - 10 I/O Slots

Dell PowerEdge R510 Technical Guide 57 11.3 RAID Configurations Table 24. Raid Configurations for the PowerEdge R510-4 PowerEdge R510-4 Factory Co

Strany 54 - 10.2 Riser 2 Detail

Dell PowerEdge R510 Technical Guide 58 Table 25. Raid Configurations for the PowerEdge R510-8 PowerEdge R510-8 Factory Confi

Strany 55 - 10.2.3 PCI Card Dimensions

Dell PowerEdge R510 Technical Guide 59 R510-8 Mixed HDD (SAS + SATA) Factory Configuration Mixed SAS + SATA (Must be all 3.5" HDDs) (ex.

Strany 56 - 11 Storage

Dell PowerEdge R510 Technical Guide 6 Table 27. Microsoft Operating Systems Supported ...

Strany 57 - 11.3 RAID Configurations

Dell PowerEdge R510 Technical Guide 60 Table 26. RAID Configuration for PowerEdge R510-12 Factory Configuration No Mixed HDD (Must be all 2.5&qu

Strany 58

Dell PowerEdge R510 Technical Guide 61 53 ASSR1/R1-X RAID1+RAID1 (PERC H200, PERC H700) 2 + 2 2 + 2 54 ASSR1/R5-X RAID1 + RAID5 (PERC H700) 2 +

Strany 59

Dell PowerEdge R510 Technical Guide 62 68 ASSR50/+iR1 RAID50 (PERC H700) 6 12 69 ASSR60/+iR1 RAID60 (PERC H700) 8 12 70 ASSR1/R1/+iR1 RAID1+R

Strany 60

Dell PowerEdge R510 Technical Guide 63 11.4 Optical Drives R510 supports a SATA interface slim DVD-ROM or slim DVD+/-RW. Slim ODD option is availab

Strany 61

Dell PowerEdge R510 Technical Guide 64 12 Video The Matrox G200eW w/ 8MB memory integrated in WPCM450 (BMC controller) provides: • 1280x1024@85Hz

Strany 62

Dell PowerEdge R510 Technical Guide 65 13 Operating Systems For the most up-to-date information, see the Operating System Support Matrix for Dell P

Strany 63 - 11.5 Tape Drives

Dell PowerEdge R510 Technical Guide 66 Table 28. Linux Operating Systems Operating Systems Version Factory Install Logo/Cert Red Hat Enterpris

Strany 64 - 12 Video

Dell PowerEdge R510 Technical Guide 67 14 Virtualization Table 29. Supported Virtualization Operating Systems Operating Systems Factory Install (F

Strany 65 - 13 Operating Systems

Dell PowerEdge R510 Technical Guide 68 15 Systems Management 15.1 Overview Dell delivers open, flexible, and integrated solutions that help you red

Strany 66

Dell PowerEdge R510 Technical Guide 69 Remote Access Controller) is responsible for acting as an interface between the host system and its manageme

Strany 67 - 14 Virtualization

Dell PowerEdge R510 Technical Guide 7 1 Overview 1.1 Product Description The PowerEdge™ R510 is a 2-socket, 2U high-capacity, multi-purpose rack s

Strany 68 - 15 Systems Management

Dell PowerEdge R510 Technical Guide 70 • Server Sensor monitoring and fault alerting • Secure operation of remote access functions including aut

Strany 69 - 15.5 iDRAC6 Express

Dell PowerEdge R510 Technical Guide 71 Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media SSL Encryption    Remote Management and

Strany 70 - 15.6 iDRAC6 Enterprise

Dell PowerEdge R510 Technical Guide 72 16 Peripherals 16.1 USB peripherals Optional External USB DVD-ROM 16.2 External Storage Refer to Table 2 for

Strany 71

Dell PowerEdge R510 Technical Guide 73 17 Packaging Options Options for single pack and multipack are available. Multipack supports 4 units in one

Strany 72 - 16 Peripherals

Dell 74 PowerEdge R510 Technical Guide Appendix A. R510 Volatility Tables Table 33. PowerEdge R510 Volatility Non-Volatile Volatile RAM Reference

Strany 73 - 17 Packaging Options

Dell 75 PowerEdge R510 Technical Guide Non-Volatile Volatile RAM Reference Designator Qty Size Type Control Panel Internal USB Y J_USBKEY (conne

Strany 74

Dell 76 PowerEdge R510 Technical Guide Table 34. Volatility: Data Writing and Purpose Can user programs or operating system write data to it during

Strany 75

Dell 77 PowerEdge R510 Technical Guide Can user programs or operating system write data to it during normal operation? Purpose? Backplane (X8) Stor

Strany 76

Dell 78 PowerEdge R510 Technical Guide Table 35. Methodology for Data Input to Memory How is data input to this memory? Planar System BIOS SPI

Strany 77

Dell 79 PowerEdge R510 Technical Guide How is data input to this memory? Chipset CMOS BIOS control only with input such as BIOS F2 menu user config

Strany 78

Dell PowerEdge R510 Technical Guide 8 comprehensive set of provisioning functions such as system deployment, system updates, hardware configuration

Strany 79

Dell 80 PowerEdge R510 Technical Guide SAS 6/iR Integrated Controller Configuration Data Loading flash memory requires a vendor-provided firmware fil

Strany 80

Dell 81 PowerEdge R510 Technical Guide How is this memory write protected? How is the memory cleared? iDRAC6 SDRAM n/a AC cycle for BMC OS and rese

Strany 81

Dell 82 PowerEdge R510 Technical Guide How is this memory write protected? How is the memory cleared? FRU Protected. No iDRAC embedded firmware wri

Strany 82

Dell PowerEdge R510 Technical Guide 9 1.2 Product Comparison Table 1 provides a detailed comparison of PowerEdge Server features using new, curren