Shrnutí obsahu

Strany 1 - User’s Guide

Dell OpenManage Server AdministratorStorage ManagementUser’s Guide

Strany 2 - Notes and Cautions

10 ContentsEnclosure and Backplane Components . . . . . 151Enclosure and Backplane Properties and Tasks . . . 151Enclosure and Backplane Properti

Strany 3 - Contents

100 ControllersPatrol Read State This property displays the current state of the Patrol Read process. Possible values are: Ready—The Patrol Read proce

Strany 4 - 4 Contents

Controllers 101Controller Tasks To execute a controller task: 1Expand the Storage tree object to display the controller objects. 2Select a controller

Strany 5

102 Controllers• Disable Alarm (Controller)• Quiet Alarm (Controller)• Test Alarm (Controller)•Set Rebuild Rate• Reset Configuration•Export Log• Forei

Strany 6 - 6 Contents

Controllers 103Available Reports• Patrol Read Report• Check Consistency Report•Slot Occupancy ReportRescan Controller Does my controller support this

Strany 7

104 ControllersEnable Alarm (Controller) Does my controller support this feature? See Supported Features.Use the Enable Alarm task to enable the contr

Strany 8 - 8 Contents

Controllers 105Controller Components For information on attached components, see the following topics:• Battery Properties and Tasks• Connector Proper

Strany 9

106 Controllersmost time to complete, and is the setting with the least impact to system performance. A rebuild rate of 0% does not mean that the rebu

Strany 10 - 10 Contents

Controllers 107Reset Configuration Does my controller support this feature? See Supported Features.Use the Reset Configuration task to erase all infor

Strany 11

108 ControllersTo locate this task in Storage Management: 1Expand the Storage tree object to display the controller objects.2Select a controller objec

Strany 12 - 12 Contents

Controllers 1095Click Execute.You can also locate this task from the Change Controller Properties drop down menu. For more information, see Change Con

Strany 13

Contents 11Connector Properties and Tasks . . . . . . . . . . . . 175Connector Properties. . . . . . . . . . . . . . . . 175Connector Tasks: Rescan

Strany 14 - 14 Contents

110 ControllersForeign Configuration PropertiesThe following table describes the properties that are displayed for the Foreign Disks and Global Hot Sp

Strany 15 - 16 BIOS Terminology

Controllers 111State This property displays the current state of the foreign configuration. Ready—The foreign disk can be imported and functions norm

Strany 16 - 16 Contents

112 ControllersBased on this information, you can decide whether you want to import, recover, or clear the foreign configuration. To preview the impor

Strany 17

Controllers 113Importing Foreign Configurations Some controllers enable you to import a foreign configuration so that virtual disks are not lost after

Strany 18 - 18 Contents

114 ControllersImporting/Recovering Foreign Configurations The recover operation attempts to restore degraded, failed, or missing virtual disks to a h

Strany 19

Controllers 115Clear Foreign Configuration Does my controller support this feature? See Supported Features.After moving a physical disk from one contr

Strany 20 - 20 Contents

116 Controllers3Select the Information/Configuration subtab. 4Select Clear Foreign Configuration from the Controller tasks.Physical Disks in Foreign V

Strany 21

Controllers 117The following table describes properties for physical disks in the foreign configuration. Table 7-5. Physical Disk PropertiesProperty D

Strany 22 - 22 Contents

118 ControllersFailure Predicted This property displays whether or not the physical disk has received a Self-Monitoring Analysis and Reporting Technol

Strany 23 - Overview

Controllers 119Bus Protocol This property displays the technology that the physical disk is using. Possible values are: SCSI—Small Computer System Int

Strany 24

12 ContentsPhysical Disk or Physical Device Tasks. . . . . . 199Blink and Unblink (Physical Disk). . . . . . . . . . . 200Remove Dead Segments. .

Strany 25 - Supported Controllers

120 ControllersVendor ID This property displays the disk’s hardware vendor. Product ID This property displays the disk’s product ID.Revision This prop

Strany 26 - Supported Enclosures

Controllers 121Set Background Initialization Rate Does my controller support this feature? See Supported Features.The Set Background Initialization Ra

Strany 27 - Overview 27

122 Controllers3Select the Information/Configuration subtab. 4Select Set Background Initialization Rate from the Available Tasks drop-down menu. 5Clic

Strany 28 - 28 Overview

Controllers 1234Select Set Check Consistency Rate from the Available Tasks drop-down menu. 5Click Execute.You can also locate this task from the Chang

Strany 29 - Getting Started

124 Controllers2Select a controller object. 3Select the Information/Configuration subtab. 4Select Set Reconstruct Rate from the Available Tasks drop-d

Strany 30 - User Privileges

Controllers 125Figure 7-1. Daisy Chain ConfigurationIf the communication channel between the connector and the first enclosure is lost, the redundant

Strany 31 - Health Subtab

126 ControllersTable 7-6. Component HealthHowever, if the communication channel between any two enclosures is lost, the redundant path configuration i

Strany 32 - Displaying the Online Help

Controllers 127Clearing the Redundant Path ViewConsider a case where you reboot your system and Storage Management, displays the Logical Connector wit

Strany 33 - Common Storage Tasks

128 ControllersThe Patrol Read does not run on a physical disk in the following circumstances: • The physical disk is not included in a virtual disk o

Strany 34 - 34 Getting Started

Controllers 129To locate this task in Storage Management: 1Expand the Storage tree object to display the controller objects. 2Select a controller obje

Strany 35 - Understanding RAID Concepts

Contents 13Number of Physical Disks per Virtual Disk . . . . . 216Maximum Number of Virtual Disks per Controller . . . . . . . . . . . . . . . . . .

Strany 36 - RAID Concepts

130 ControllersRelated Information: •Set Patrol Read ModeChange Controller PropertiesDoes my controller support this feature? See Supported Features.T

Strany 37 - Performance

Controllers 1312Select a controller object.3Select the Information/Configuration subtab.4Select Change Controller Properties... from the Controller Ta

Strany 38

132 Controllers• Customized Power Savings Mode—provides the option for you to customize the power savings settings. The default values are populated w

Strany 39 - Concatenation

Controllers 133Table 7-8. Manage Physical Disk Power PropertiesTo manage physical disk power on unconfigured drives and hot spares:1Select Enabled for

Strany 40 - RAID Level 0 (Striping)

134 Controllers2You can now edit the remaining parameters on the Manage Physical Disk Power screen. You can also configure the options in the QOS sect

Strany 41 - RAID 0 Characteristics:

Controllers 135Data in the cache may also be lost in case of unintended cable or power failure. In the event of such a failure, Storage Management pre

Strany 42 - RAID Level 1 (Mirroring)

136 ControllersManage Encryption Key NOTE: To configure encryption, you do not require an SED. However, to create a secure virtual disk, you require

Strany 43 - RAID 5 Characteristics:

Controllers 137If you are using Local Key Management (LKM) you must create the Encryption Key by providing the Encryption Key Identifier and the Passp

Strany 44

138 Controllers4If you want to save the Encryption Key credentials in a file on the system where Distributed Web Server is running, select the Escrow

Strany 45 - RAID 6 Characteristics:

Controllers 139Encryption Key credentials for a controller, providing the path of the file updates credentials for that controller. If the credentials

Strany 46

14 ContentsVirtual Disk Task: Reconfigure (Step 1 of 3) . . . . . . 249Virtual Disk Task: Reconfigure (Step 2 of 3). . . . . . 251Virtual Disk Tas

Strany 47 - RAID 50 Characteristics:

140 Controllers3Enter a name for the CacheCade. The size is calculated as follows:CacheCade size = capacity of the smallest SSD * the number of SSDs4F

Strany 48

Controllers 141To unblink the physical disk in the CacheCade(s) screen, go to the CacheCade Disk that you want to unblink and select Unblink... from t

Strany 49 - RAID 60 Characteristics:

142 ControllersConvert to Non-RAID DisksOn Dell PERC H310 adapters, drop-down the controller tasks drop-down menu and select the task Convert to Non-R

Strany 50

Controllers 143Convert to RAID Capable DisksOn Dell PERC H310 adapters, drop-down the controller tasks drop-down menu and select the task Convert to R

Strany 51 - RAID 10 Characteristics:

144 ControllersSlot Occupancy ReportDoes my controller support this feature? See Supported Features.The View Slot Occupancy Report task allows you to

Strany 52

Enclosures and Backplanes 1458Enclosures and Backplanes Physical disks can be contained in an enclosure or attached to the system’s backplane. An encl

Strany 53

146 Enclosures and BackplanesStorage Management displays the properties of the enclosure’s fans, power supply, and temperature probes. Storage Managem

Strany 54

Enclosures and Backplanes 147The Failure threshold has a default value that cannot be changed. You can set the Warning threshold, however. For informa

Strany 55

148 Enclosures and BackplanesSMART Thermal ShutdownDoes my enclosure support this feature? See Supported Features.Enclosure management provides a feat

Strany 56

Enclosures and Backplanes 149Changing the Mode on PowerVault 220S and PowerVault 221S Enclosures When toggling the bus configuration switch on a Power

Strany 57 - Storage Health

Contents 1514 Protecting Your Virtual Disk with a Hot Spare . . . . . . . . . . . . . . . . . . . . . . . 269Understanding Hot Spares. . . . . . . .

Strany 58 - Storage Component Severity

150 Enclosures and Backplanes• If you have already removed the wrong physical disk, see Recovering from Removing the Wrong Physical Disk. • Identifyin

Strany 59

Enclosures and Backplanes 151Table 8-1. Component SeverityEnclosure and Backplane Information For information on enclosures and backplanes, see the fo

Strany 60 - Alerts or Events

152 Enclosures and BackplanesTable 8-2. Enclosure and Backplane PropertiesProperty Definition These icons represent the severity or health of the stor

Strany 61

Enclosures and Backplanes 153Configuration This property displays the mode in which the enclosure is operating. Possible values are: Joined—Indicates

Strany 62 - Physical Disk Status Changes

154 Enclosures and BackplanesEnclosure Tasks To execute a drop-down menu enclosure task: 1Expand the Storage tree object to display the controller obj

Strany 63

Enclosures and Backplanes 155Drop-down Menu Enclosure Tasks:• Enable Alarm (Enclosure)• Disable Alarm (Enclosure)• Set Asset Data•Blink• Set Temperatu

Strany 64

156 Enclosures and BackplanesDisable Alarm (Enclosure) Does my enclosure support this feature? See Supported Features.Use the Disable Alarm task to di

Strany 65 - PCIe SSD Features

Enclosures and Backplanes 157View Slot Occupancy Report Does my controller support this feature? See Supported Features.The View Occupancy Slot Report

Strany 66 - PCIe Sub System Properties

158 Enclosures and BackplanesFor information related to the enclosure’s temperature, see the following: • Enclosure Temperature Probes• Set Temperatur

Strany 67 - Physical Device Properties

Enclosures and Backplanes 159Set Asset DataDoes my enclosure support this feature? See Supported Features.You can change the enclosure’s asset tag and

Strany 68

16 ContentsBIOS Terms and the CERC SATA1.5/6ch and CERC SATA1.5/2s Controllers. . . . . . . . . . . . . . . . . 27917 Troubleshooting . . . . . . .

Strany 69

160 Enclosures and BackplanesThe Failure threshold indicates that the enclosure has reached a dangerous temperature that may cause damage and data los

Strany 70

Enclosures and Backplanes 161View Slot Occupancy ReportDoes my controller support this feature? See Supported Features.The View Occupancy Slot Report

Strany 71 - Physical Device Tasks

162 Enclosures and BackplanesTable 8-3. EMM PropertiesProperty Definition Status These icons represent the severity or health of the storage componen

Strany 72 - PCIe SSD Sub System Health

Enclosures and Backplanes 163Fan PropertiesUse this window to view information about the enclosure’s fans. The fans are a component of the enclosure’s

Strany 73 - Backplane Firmware Version

164 Enclosures and BackplanesTable 8-4. Fan PropertiesProperty Definition Status These icons represent the severity or health of the storage componen

Strany 74

Enclosures and Backplanes 165Power Supply Properties Use this window to view information about the enclosure’s power supplies. Table 8-5. Power Supply

Strany 75 - Global Tasks

166 Enclosures and BackplanesFirmware Version This property displays the firmware version number of the power supply. The firmware version of power su

Strany 76 - Global Rescan

Enclosures and Backplanes 167Temperature Probe Properties and TasksDoes my enclosure support this feature? See Supported Features.Use this window to v

Strany 77 - Storage Controllers

168 Enclosures and BackplanesState This property displays the current status of the temperature probe. Ready—The temperature probe is functioning nor

Strany 78

Enclosures and Backplanes 169Set Temperature Probe Properties and Tasks Click the Set Temperature Probe button to launch the wizard for changing the t

Strany 79

Contents 17A Disk on a PERC 4/Di Controller Does not Return Online after a Prepare to Remove . . . . . 292Receive a “Bad Block” Alert with “Replaceme

Strany 80

170 Enclosures and Backplanes

Strany 81

Connectors 1719Connectors A controller contains one or more connectors (channels or ports) to which you can attach disks. A connector is externally ac

Strany 82 - SAS RAID Controllers

172 ConnectorsChannel Redundancy on PERC 4/DC, 4e/DC, 4/Di, and 4e/Di Controllers The following considerations apply when creating a channel-redundant

Strany 83 - RAID Controller Features

Connectors 173Recommended RAID Levels: –PERC 4/DC, 4e/DC, 4/Di, and 4e/Di Controllers—It is recommended that you only use RAID 10 or RAID 50. 3Complet

Strany 84

174 ConnectorsbSelect an additional disk on each of the three channels. You have now selected the minimum number of disks for a RAID 50. Continue sele

Strany 85 - Cache Policy

Connectors 175Table 9-1. Component SeverityConnector Information For information on the connector, see the following topics: • Connectors• Connector P

Strany 86 - Write Policy

176 ConnectorsTable 9-2. Connector PropertiesProperty Definition These icons represent the severity or health of the storage component. For more infor

Strany 87

Connectors 177Connector Tasks: Rescan Connector Does my controller support this feature? See Supported Features.On a SCSI controller, this task rescan

Strany 88 - Disk Cache Policy

178 ConnectorsTable 9-3. Logical Connector PropertiesPath HealthThe path health of the connectors is represented as normal, warning, or critical. The

Strany 89 - Cluster-enabled Controllers

Connectors 179Selecting this option clears the redundant path view and the connectors are represented on the user interface as Connector 0 and Connect

Strany 90 - Controller

18 ContentsHow do I Recover from Removing the Wrong Physical Disk? . . . . . . . . . . . . . . . . . . . . . . . . . . 300How do I Identify the Firm

Strany 92 - Firmware/Driver Versions

RAID Controller Batteries 18110RAID Controller Batteries Some RAID controllers have batteries. If the controller has a battery, Storage Management dis

Strany 93

182 RAID Controller BatteriesAll RAID controller batteries should be replaced every three years. You must also monitor the Recharge Count and Max Rech

Strany 94 - Controller Health

RAID Controller Batteries 183Table 10-1. Battery PropertiesProperty Definition Status These icons represent the severity or health of the storage com

Strany 95 - Controller Components

184 RAID Controller BatteriesPredicted Capacity StatusThis property displays the charge capacity of the battery. Possible values are: Ready—The batter

Strany 96 - Controller Properties

RAID Controller Batteries 185Battery Tasks To execute a drop-down menu battery task: 1Expand the Storage tree object to display the controller objects

Strany 97

186 RAID Controller BatteriesThe controller battery should be reconditioned when either of the following occurs: • The controller reports the battery

Strany 98 - 98 Controllers

RAID Controller Batteries 187The battery learn cycle discharges and then fully charges the controller battery. The Learn cycle recalibrates the batter

Strany 99

188 RAID Controller BatteriesTo delay the battery learn cycle: 1Type a numerical value in the Days text box. The value must be within the 0 – 7 range.

Strany 100 - 100 Controllers

Physical Disks or Physical Devices 18911Physical Disks or Physical DevicesPhysical disks or physical devices reside within an enclosure or are attache

Strany 101 - Controller Tasks

Contents 19Supported Features on the PERC 5/ PERC 6/, and CERC 6/I Controllers. . . . . . . . . . . . . . . . . . . 322Controller Tasks. . . . . . .

Strany 102 - Available Reports

190 Physical Disks or Physical Devices NOTE: With the exception of combining SAS,SATA,SCSI, and SSD drives, Dell supports upgrades and not downgrades

Strany 103 - Controllers 103

Physical Disks or Physical Devices 191• If you want to include the new disk in a virtual disk, see Virtual Disk Considerations for Controllers or Virt

Strany 104 - Controllers

192 Physical Disks or Physical Devices4Insert a new disk. Make sure that the new disk is the same size or larger as the disk you are replacing. On som

Strany 105 - Set Rebuild Rate

Physical Disks or Physical Devices 193Physical Disk or Physical Device Properties The following table describes properties that may be displayed for p

Strany 106

194 Physical Disks or Physical DevicesState This property displays the current state of the physical disk or device. Ready—The physical disk or devic

Strany 107 - Reset Configuration

Physical Disks or Physical Devices 195Rebuilding—Data from a redundant virtual disk is currently being rebuilt onto the physical disk or device. Incom

Strany 108 - Export Log

196 Physical Disks or Physical DevicesReplacing—A Replace Member Disk task is being performed on the physical disk or device. For more information, se

Strany 109

Physical Disks or Physical Devices 197Failure Predicted This property displays whether or not the physical disk or device has received a SMART alert a

Strany 110 - Disks and Global Hot Spares

198 Physical Disks or Physical DevicesBus Protocol This property displays the technology that the physical disk or device is using. Possible values ar

Strany 111

Physical Disks or Physical Devices 199Physical Disk or Physical Device Tasks To execute a physical disk or physical device task: 1Expand the Storage t

Strany 112

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates poten

Strany 113 - Controllers 113

20 ContentsSupported Features on the PERC S100, PERC S110, and S300 Controllers. . . . . . . . . . . . . . . . . . 353Controller Tasks. . . . . . .

Strany 114

200 Physical Disks or Physical Devices NOTE: Different controllers support different features. For this reason, the tasks displayed on the Tasks drop

Strany 115 - Clear Foreign Configuration

Physical Disks or Physical Devices 201into a server or an enclosure. If the physical disk is not contained in a carrier but is instead designed to be

Strany 116

202 Physical Disks or Physical DevicesA physical disk or physical device is no longer in Ready state after doing a Prepare to Remove. Removing the phy

Strany 117

Physical Disks or Physical Devices 203Rebuilding a disk may take several hours.Cancel Rebuild Does my controller support this feature? See Supported F

Strany 118 - 118 Controllers

204 Physical Disks or Physical DevicesGlobal hot spares must be assigned and unassigned manually. They are not assigned to specific virtual disks. If

Strany 119

Physical Disks or Physical Devices 205Use the Offline task to deactivate a disk before removing it. Use the Online task to reactivate an offline disk.

Strany 120 - 120 Controllers

206 Physical Disks or Physical Devices NOTE: A physical disk may display the Clear state if it is a member of a virtual disk that is being slow initi

Strany 121

Physical Disks or Physical Devices 207If Revertible Hot Spare is enabled and the physical disk is SMART-enabled, the controller firmware automatically

Strany 122 - Set Check Consistency Rate

208 Physical Disks or Physical DevicesTo locate this task in Storage Management: 1Expand the Storage tree object to display the controller objects. 2E

Strany 123 - Set Reconstruct Rate

Physical Disks or Physical Devices 209Convert to RAID Capable DiskThis task enables a disk for all RAID operations. This task is supported on H310 con

Strany 124 - Redundant Path Configuration

Contents 21Health Status Rollup: Physical Disks in a Virtual Disk are Unsupported, Partially or Permanently Degraded. . . . . . . . . . . . . . . . .

Strany 125

210 Physical Disks or Physical Devices

Strany 126

Virtual Disks 21112Virtual DisksIn order to implement RAID functions, RAID controllers must create a virtual disk. A virtual disk refers to storage cr

Strany 127 - Set Patrol Read Mode

212 Virtual Disks• Understanding Hot Spares• Controller-supported Stripe Sizes• Rescan to Update Storage Configuration Changes• Time Delay in Displayi

Strany 128 - To set the Patrol Read mode:

Virtual Disks 213virtual disks can result in pockets of free space residing in various locations on the physical disks. When you create a new virtual

Strany 129 - Start and Stop Patrol Read

214 Virtual Disks•Implementing channel redundancy—A virtual disk is channel-redundant when it maintains redundant data on more than one channel. If on

Strany 130 - Change Controller Properties

Virtual Disks 215For related information, see Considerations for CERC SATA1.5/6ch and CERC SATA1.5/2s Controllers When Physical Disks are Shared by Re

Strany 131 - Manage Physical Disk Power

216 Virtual DisksThe support provided by your operating system depends on the version of the operating system and any updates or modifications that yo

Strany 132

Virtual Disks 217Calculation for Maximum Virtual Disk Size and the Create Virtual Disk Express Wizard The Create Virtual Disk Express Wizard displays

Strany 133

218 Virtual DisksCreating Virtual Disks Does my controller support this feature? See Supported Features.In order to implement RAID functions, you need

Strany 134 - Manage Preserved Cache

Virtual Disks 219To reconfigure a virtual disk: 1Review the information in Starting and Target RAID Levels for Virtual Disk Reconfiguration and Capaci

Strany 135

22 Contents

Strany 136 - Manage Encryption Key

220 Virtual DisksPERC 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, PERC 4e/Di, PERC 5/E, and PERC 5/iRAID 0 RAID 5 Add at least one additional disk PERC 4/SC, PE

Strany 137 - Enabling LKM

Virtual Disks 221PERC 6/E, PERC 6/I, CERC 6/I, PERC H800 Adapter, PERC H700 Adapter, PERC H700 Integrated, and PERC H700 Modular, PERC H310 Adapter, P

Strany 138

222 Virtual DisksRAID 0 RAID 6 RAID 6 requires a minimum of 4 disks. Reconfiguration from RAID 0 to RAID 6 requires at least 2 additional disks even

Strany 139 - Manage CacheCade

Virtual Disks 223Exceptions for Reconfiguring a Concatenated Virtual Disk on CERC SATA1.5/6ch and CERC SATA1.5/2s Controllers You can create a concate

Strany 140 - Renaming the CacheCade

224 Virtual DisksRebuilding Redundant InformationDoes my controller support this feature? See Supported Features.If you have a redundant virtual disk,

Strany 141 - CacheCade Properties

Virtual Disks 225The following table describes some of the possible scenarios that may/may not result in virtual disk bad blocks:Table 12-2. Sample Sc

Strany 142 - Convert to Non-RAID Disks

226 Virtual DisksRecommendationsStorage Management provides the ability to clear the bad block warnings. To clear bad blocks, the following procedure

Strany 143 - Check Consistency Report

Virtual Disks 227Virtual Disk Properties and Tasks Use this window to view information about the virtual disks and execute virtual disk tasks. Virtual

Strany 144 - Slot Occupancy Report

228 Virtual DisksState This property displays the current status of the virtual disk. Possible values are: Ready—The virtual disk is functioning norm

Strany 145 - Enclosures and Backplanes

Virtual Disks 229Background Initialization—A background initialization is being performed on the virtual disk. Formatting—The virtual disk is being fo

Strany 146 - Enclosure Temperature Probes

Overview 231OverviewDell OpenManage Server Administrator Storage Management provides enhanced features for configuring a system's locally-attache

Strany 147 - Enclosures and Backplanes 147

230 Virtual DisksVirtual Disk Tasks To execute a virtual disk drop-down menu task: Bus Protocol This property displays the technology that the physica

Strany 148 - SMART Thermal Shutdown

Virtual Disks 2311Expand the Storage tree object to display the controller objects. 2Expand a controller object. 3Select the Virtual Disks object. 4Se

Strany 149 - Enclosure Management

232 Virtual Disks• Encrypt Virtual DiskReconfigure Does my controller support this feature? See Supported Features.Use the Reconfigure task to change

Strany 150

Virtual Disks 233however, cancel the background initialization. When you do so, the controller restarts the background initialization at a later time.

Strany 151

234 Virtual DisksCheck Consistency Does my controller support this feature? See Supported Features.Use the Check Consistency task to verify the accura

Strany 152 - 152 Enclosures and Backplanes

Virtual Disks 235in Resynching state causes the virtual disk to be in a Failed Redundancy state. For more information, see Considerations for Concaten

Strany 153

236 Virtual DisksChange Policy Does my controller support this feature? See Supported Features.Use the Change Policy task to change a virtual disk’s r

Strany 154 - Enclosure Tasks

Virtual Disks 237• have Self Encryption Drives (SEDs) virtual disksCreate Virtual Disk Express Wizard (Step 1 of 2) Does my controller support this fe

Strany 155

238 Virtual Disks– Select RAID 5 for striping with distributed parity. This selection groups n disks together as one large virtual disk with a total c

Strany 156

Virtual Disks 239 NOTE: The CERC SATA1.5/2s controller does not allow you to specify a name for concatenated virtual disks. The concatenated virtual

Strany 157 - Enclosures and Backplanes 157

24 Overviewbackplanes. The backplane can be identified by the bay ID which is displayed on the screen. This ID is also displayed on the bezel of the s

Strany 158 - Enclosure Components

240 Virtual DisksIf you need to change a selection, click Go Back To Previous Page to return to Create Virtual Disk Express Wizard (Step 1 of 2). NO

Strany 159 - Set Temperature Probe Values

Virtual Disks 241Create Virtual Disk Advanced Wizard (Step 1 of 4) Does my controller support this feature? See Supported Features.The Create Virtual

Strany 160 - Temperature Probe Status

242 Virtual DisksThis feature provides better data redundancy and read performance, but slower write performance. Your system must have at least three

Strany 161 - EMM Properties

Virtual Disks 243The algorithm determines the candidate mirror in the following order:• Across connectors at the same level of enclosure and of same s

Strany 162 - 162 Enclosures and Backplanes

244 Virtual Disks3Click Continue to go to the next screen or Exit Wizard if you want to cancel. To locate this task in Storage Management: 1Expand the

Strany 163 - Fan Properties

Virtual Disks 245Connector 0The Connector section of the screen displays the controller's connectors and the disks attached to each connector. Se

Strany 164 - 164 Enclosures and Backplanes

246 Virtual Disks NOTE: This option is available only if you did not select Intelligent Mirroring on the Create Virtual Disk (Step 1 of 4) page. NOTE

Strany 165 - Power Supply Properties

Virtual Disks 247the controller. In most cases, the maximum length is 15 characters. The name cannot start with a space or end with a space. It is rec

Strany 166 - 166 Enclosures and Backplanes

248 Virtual DisksCreate Virtual Disk Advanced Wizard (Step 4 of 4) Does my controller support this feature? See Supported Features.This screen display

Strany 167

Virtual Disks 249This option is available only if the controller is a SAS controller with firmware 6.1 and later and you selected RAID 10. NOTE: If y

Strany 168 - 168 Enclosures and Backplanes

Overview 25Version Requirements for Controller Firmware and Drivers In order for Storage Management to function properly, the controllers must have th

Strany 169 - Enclosures and Backplanes 169

250 Virtual DisksBefore continuing with the virtual disk reconfiguration, you should be familiar with the information in Starting and Target RAID Leve

Strany 170 - 170 Enclosures and Backplanes

Virtual Disks 251Monolithic, PERC H800, and PERC H810 Adapter controllers, if the disk group has free space available, you can expand the virtual disk

Strany 171 - Connectors

252 Virtual Disks– Select RAID 0 for striping—This selection groups n disks together as one large virtual disk with a total capacity of n disks. Data

Strany 172

Virtual Disks 253 NOTE: The PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di controllers do not allow you to change or reconfigure the virtual disk siz

Strany 173

254 Virtual DisksConsiderations for Concatenated to RAID 1 Reconfiguration on CERC SATA1.5/6ch Controllers When reconfiguring a concatenated virtual d

Strany 174 - Connector Health

Virtual Disks 255Considerations for Initialize The initialize task applies to the PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di controllers. These co

Strany 175 - Connector Properties

256 Virtual DisksIn comparison with the Fast Initialize task, you may want to use the Slow Initialize task if you have had trouble with a physical dis

Strany 176 - 176 Connectors

Virtual Disks 257– Slow Initialize– Fast Initialize5Click Execute. Virtual Disk Task: Delete Does my controller support this feature? See Supported Fe

Strany 177 - Logical Connector Properties

258 Virtual Disks3Select the Virtual Disks object. 4Select Delete from the Available Tasks drop-down menu. 5Click Execute. Virtual Disk Task: Rename D

Strany 178 - Path Health

Virtual Disks 2593Select the Virtual Disks object. 4Select Rename from the Available Tasks drop-down menu. 5Click Execute. Virtual Disk Task: Change P

Strany 179 - Logical Connector Components

26 Overview• PERC 6/I Integrated and PERC 6/I Adapter•PERC 6/I Modular•CERC 6/I controller • SAS 6/iR controller • PERC S100, PERC S110, and S300• PER

Strany 180 - 180 Connectors

260 Virtual Disks NOTE: On the CERC SATA1.5/6ch controllers, doing a Split Mirror on a RAID 1-concatenated virtual disk results in concatenated virtu

Strany 181 - RAID Controller Batteries

Virtual Disks 261Unmirror Does my controller support this feature? See Supported Features.Use the Unmirror task to separate mirrored data and restore

Strany 182 - Battery Properties and Tasks

262 Virtual Disks• Time Delay in Displaying Configuration ChangesAssign and Unassign Dedicated Hot Spare Does my controller support this feature? See

Strany 183

Virtual Disks 263To locate this task in Storage Management: 1Expand the Storage tree object to display the controller objects. 2Expand a controller ob

Strany 184 - 184 RAID Controller Batteries

264 Virtual Disks3Click Apply Changes. To exit without replacing the member disk, click Go Back To Virtual Disk Page. NOTE: For PERC H310, H700, H710

Strany 185 - Battery Tasks

Moving Physical and Virtual Disks from One System to 13Moving Physical and Virtual Disks from One System to Another This section describes how to move

Strany 186 - Start Learn Cycle

266 Moving Physical and Virtual Disks from One System to Another• A virtual disk cannot be migrated between the CERC SATA1.5/6ch and CERC SATA1.5/2s c

Strany 187 - Battery Delay Learn Cycle

Moving Physical and Virtual Disks from One System to Another 267• Saving the New Controller ConfigurationMoving the Disks 1Turn off the system that th

Strany 188 - Related Information:

268 Moving Physical and Virtual Disks from One System to Another5This reads the data on the physical disks to restore the RAID controller’s proprietar

Strany 189 - Physical Device

Protecting Your Virtual Disk with a Hot Spare 26914Protecting Your Virtual Disk with a Hot SpareWhen you create a redundant virtual disk using a RAID

Strany 190 - Add a New Disk to Your System

Overview 27• PowerVault MD1000 and MD1120 storage system• PowerVault MD1200 and MD1220 storage systemSupport for Disk and Volume ManagementStorage Man

Strany 191

270 Protecting Your Virtual Disk with a Hot SpareSetting Hot Spare Protection PolicyThe Hot Spare Protection Policy is supported only on Serial Attach

Strany 192 - Other Disk Procedures

Protecting Your Virtual Disk with a Hot Spare 271Global Hot Spare Protection PolicyTable 14-2. Global Hot Spare Properties NOTE: When assigning a glo

Strany 193

272 Protecting Your Virtual Disk with a Hot Spare• Enclosure affinity settings for a global/dedicated hot spare are not automatically set when you upg

Strany 194

Protecting Your Virtual Disk with a Hot Spare 273A dedicated hot spare can only be assigned to the set of virtual disks that share the same physical d

Strany 195

274 Protecting Your Virtual Disk with a Hot Spare NOTE: For H700 and H800 controllers, you can assign a dedicated hot spare to RAID 10, RAID 50, and

Strany 196

Protecting Your Virtual Disk with a Hot Spare 275 NOTE: When using the BIOS on a CERC SATA1.5/6ch controller, it may be possible to create a hot spar

Strany 197

276 Protecting Your Virtual Disk with a Hot SpareGlobal Hot Spare Considerations on a SAS 6/iR The SAS 6/iR controller enables you to assign two globa

Strany 198

CacheCade Using Solid State Drives 27715CacheCade Using Solid State DrivesCacheCade is used to improve random read performance of the Hard Disk Drive

Strany 199

278 CacheCade Using Solid State Drives• The total amount of cache pool with a CacheCade is 512 GB. If you create a CacheCade which is larger than 512

Strany 200

BIOS Terminology 27916BIOS Terminology The terminology used by Storage Management can be different from the terminology used in the controller BIOS. T

Strany 202 - Rebuild

280 BIOS TerminologyConcatenation of RAID 1 VolumeRAID 0 RAID-0 (Stripe)RAID 1 RAID-1 (Mirror)Diagnostics VerifyTable 16-2. Naming convention differen

Strany 203 - Cancel Rebuild

Troubleshooting 28117Troubleshooting This section contains troubleshooting procedures for common situations as well as for specific problems. Common T

Strany 204 - Online and Offline

282 TroubleshootingSystem RequirementsMake sure that the system meets all system requirements. In particular, verify that the correct levels of firmwa

Strany 205

Troubleshooting 283Replacing a Failed Disk You may need to replace a failed disk in the following situations: • Replacing a Failed Disk that is Part o

Strany 206 - Revertible Hot Spare

284 TroubleshootingReplacing a Failed Physical Disk that is Part of a Non-Redundant Virtual DiskIf the failed physical disk is part of a non-redundant

Strany 207 - Instant Encrypt Erase

Troubleshooting 285After retrieving any viable data from the disk, replace the failed disk as described previously in Replacing a Failed Disk that is

Strany 208 - Full Initialization

286 Troubleshooting• Rebuild for PERC 4/SC, 4/DC, 4e/DC, 4/Di, PERC 5/E and PERC 5/i controllers You can avoid removing the wrong physical disk by bli

Strany 209 - Convert to Non-RAID Disk

Troubleshooting 287•The virtual disk is non-redundant—For example, a RAID 0 virtual disk cannot be rebuilt because RAID 0 does not provide data redund

Strany 210

288 Troubleshooting•The virtual disk includes failed or corrupt physical disks—This situation may generate alert 2083. For information on Alert Messag

Strany 211 - Virtual Disks

Troubleshooting 2893Restore the virtual disk from the tape onto healthy physical disks. Cannot Create a Virtual Disk You might be attempting a RAID co

Strany 212

Getting Started 292Getting Started Dell OpenManage Server Administrator Storage Management is designed for system administrators who implement hardwar

Strany 213 - Virtual Disks 213

290 Troubleshooting2Delete the virtual disk.3Create one or more virtual disks that are smaller than 1TB.4Restore your data from backup. Irrespective o

Strany 214

Troubleshooting 291Resolution: Perform a Rescan Controller. When the rescan is complete, select each physical disk that is Offline and perform a Remov

Strany 215 - Virtual Disks 215

292 TroubleshootingPhysical Disk is Offline or Displays an Error Status A physical disk may display an error status if it has been damaged, taken offl

Strany 216

Troubleshooting 293Receive a “Bad Block” Alert with “Replacement,” “Sense,” or “Medium” Error The following alerts or events are generated when a port

Strany 217 - Express Wizard

294 TroubleshootingAlerts 2146 through 2150 Received while Performing I/O, Consistency Check, Format, or Other OperationIf you receive alerts 2146 thr

Strany 218 - Creating Virtual Disks

Troubleshooting 295A Corrupt Disk or Drive Message Suggests Running autocheck During a Reboot Let autocheck run, but do not worry about the message. T

Strany 219

296 TroubleshootingCannot Connect to Remote System Running Windows Server 2003When connecting to a remote system running Windows Server 2003, log into

Strany 220 - (continued)

Troubleshooting 297PCIe SSD TroubleshootingPeripheral Component Interconnect Express (PCIe) Solid-State Drive (SSD) is not seen in the operating syste

Strany 221

298 Troubleshooting

Strany 222 - 222 Virtual Disks

Frequently Asked Questions 29918Frequently Asked Questions This section provides frequently asked questions that address situations commonly experienc

Strany 223

Contents 3Contents1Overview . . . . . . . . . . . . . . . . . . . . . . . . . 23What’s New in this Release? . . . . . . . . . . . . . . 23Before I

Strany 224

30 Getting StartedLaunching Storage Management Storage Management is installed as a Dell OpenManage Server Administrator service. All Storage Manageme

Strany 225

300 Frequently Asked QuestionsHow do I Recover from Removing the Wrong Physical Disk?For more information, see Recovering from Removing the Wrong Phys

Strany 226 - Recommendations

Frequently Asked Questions 3013To display more information about a particular controller including its tasks, click the controller’s name in the Name

Strany 227 - Virtual Disk Properties

302 Frequently Asked Questions

Strany 228 - 228 Virtual Disks

Supported Features 303ASupported Features Different controllers support different features. The tasks displayed by the Storage Management menus and ot

Strany 229

304 Supported FeaturesDisable Alarm Yes Yes No No No Yes No Quiet Alarm Yes YesNoNoNoYes No Test Alarm No NoNoNoNoNo NoReset configurationYes Yes Yes

Strany 230 - Virtual Disk Tasks

Supported Features 305Battery Tasks Connector Tasks Set Patrol Read ModeNOTE: For PERC 4 controllers, (Manual mode is not available).Yes Yes Yes Yes Y

Strany 231

306 Supported FeaturesPhysical Disk Tasks Table A-4. Physical Disk Tasks Supported by the PERC 4/ ControllersPhysical Disk Task Name PERC 4/SCPERC 4/D

Strany 232

Supported Features 307Virtual Disk Tasks Table A-5. Virtual Disk Tasks Supported by the PERC 4/ ControllersVirtual Disk Task Name PERC 4/SCPERC 4/DCPE

Strany 233 - Rebuild Rate

308 Supported FeaturesResume Check ConsistencyNo No No No No No NoCancel Background Initialization (BGI)YesYesYesYesYesYesNoFormat Virtual DiskNo No N

Strany 234

Supported Features 309Virtual Disk Specifications Table A-6. Virtual Disk Specifications for the PERC 4/ ControllersVirtual Disk Specification PERC 4/

Strany 235

Getting Started 31Administrator privileges are required to access all Storage Management features. Administrator privilege allows you to execute the d

Strany 236

310 Supported FeaturesMaximum Number of Physical Disks that Can Be Concatenated888888NAMaximum Number of Physical Disks in a RAID 032 32 32 32 32 32 N

Strany 237 - Virtual Disks 237

Supported Features 311Minimum Number of Physical Disks that Can Be Concatenated 2 2 2222 NAMinimum Number of Physical Disks in a RAID 0 1 1 1111 NAMin

Strany 238

312 Supported FeaturesSupported RAID Levels Maximum number of physical disks in a RAID 6NA NA NA NA NA NA NAMaximum number of physical disks in a RAID

Strany 239

Supported Features 313Read, Write, and Disk Cache Policy Table A-8. Read, Write and Disk Cache Policy Supported by the PERC 4/ ControllersRead, Write,

Strany 240

314 Supported FeaturesEnclosure Support Supported Features on the CERC SATA Controllers This section identifies the controller-supported features and

Strany 241 - Virtual Disks 241

Supported Features 315Controller Tasks Table A-10. Controller Tasks Supported by the CERC SATA ControllersController Task Name CERC SATA 1.5/2sCERC S

Strany 242

316 Supported FeaturesBattery Tasks Connector Tasks Physical Disk Tasks Table A-11. Battery Tasks Supported by the CERC SATA ControllersBattery Task N

Strany 243

Supported Features 317Virtual Disk Tasks Format Disk No NoClear No NoCancel Clear No NoTable A-14. Virtual Disk Tasks Supported by the CERC SATA Contr

Strany 244

318 Supported FeaturesVirtual Disk Specifications Resume Check ConsistencyNo YesCancel Background Initialization (BGI)No NoFormat Virtual Disk No YesC

Strany 245 - Physical Disks Selected

Supported Features 319Maximum Number of Physical Disks per Span 22Minimum Stripe Size 16k 8kMaximum Stripe Size 64k 64kMaximum Number of Virtual Disks

Strany 246

32 Getting Startedthe tree view and then select the Information/Configuration subtab. The Information/Configuration subtabs have task drop-down menus

Strany 247

320 Supported FeaturesSupported RAID Levels Minimum Number of Physical Disks in a RAID 10NA 4Minimum Number of Physical Disks in a RAID 50NA NAMaximum

Strany 248

Supported Features 321Read, Write, and Disk Cache Policy Enclosure Support Table A-17. Read, Write, and Cache Policy Supported by the CERC SATA Contro

Strany 249 - Span Edit

322 Supported FeaturesSupported Features on the PERC 5/ PERC 6/, and CERC 6/I ControllersThis section identifies the controller-supported features and

Strany 250

Supported Features 323Set Check Consistency RateYes Yes Yes Yes Yes YesSet Reconstruct RateYes Yes Yes Yes Yes YesRescan Controller No No No No No No

Strany 251 - Virtual Disks 251

324 Supported FeaturesHot-plug of Enclosures No No Yes with firmware 6.1 and laterNo No NoChange Controller Properties No No Yes with firmware 6.1 and

Strany 252

Supported Features 325Battery Tasks Connector Tasks Physical Disk Tasks Table A-20. Battery Tasks Supported on the PERC 5/E, PERC 6/, and CERC 6/I Con

Strany 253

326 Supported FeaturesVirtual Disk Tasks Cancel Rebuild Yes Yes Yes Yes Yes YesRemove Dead Disk SegmentsNo No No No No NoFormat Disk No No No No No No

Strany 254 - Considerations for Format

Supported Features 327Unmirror No No No No No NoDelete Last Virtual DiskYesYesYesYesYesYesDelete (any) Virtual Disk YesYesYesYesYesYesCheck Consistenc

Strany 255

328 Supported FeaturesVirtual Disk Specifications Table A-24. Virtual Disk Specifications for the PERC 5/, PERC 6/, and CERC 6/I ControllersVirtual Di

Strany 256

Supported Features 329Maximum Number of Physical Disks in a RAID 1016 16 256 with firmware version 6.116 16 16Maximum Number of Physical Disks in a RA

Strany 257 - Virtual Disk Task: Delete

Getting Started 33Common Storage TasksThis section provides links to information describing commonly performed storage tasks. • Create and configure v

Strany 258 - Virtual Disk Task: Rename

330 Supported FeaturesSupported RAID Levels Read, Write, Cache and Disk Cache PolicyMinimum number of physical disks in a RAID 6NA NA 4 4 4 4Minimum n

Strany 259 - Split Mirror

Supported Features 331Enclosure Support Read Policy YesYesYesYesYesYesRead Ahead (Enabled) Yes Yes Yes Yes Yes YesAdaptive Read Ahead Yes Yes Yes Yes

Strany 260 - To Split a Mirror:

332 Supported FeaturesSupported Features on the PERC Hardware ControllersThis section identifies the controller-supported features and whether or not

Strany 261 - Unmirror

Supported Features 333Controller TasksTable A-28. Controller Tasks Supported on the PERC Hardware ControllersController Task NamePERC H800PERC H810 Ad

Strany 262

334 Supported FeaturesClear Foreign Configuration Yes Yes Yes Yes Yes Yes YesImport Foreign ConfigurationYes Yes Yes Yes Yes Yes YesImport/Recover For

Strany 263

Supported Features 335Intelligent Mirroring Yes Yes Yes Yes Yes Yes YesRedundant Path ConfigurationYes Yes No No No No NoDisk Cache PolicyYes Yes Yes

Strany 264

336 Supported FeaturesBattery TasksPatrol Read ReportYes Yes Yes Yes Yes Yes YesCheck Consistency ReportYes Yes Yes Yes Yes Yes YesSlot Occupancy Repo

Strany 265 - Required Conditions

Supported Features 337Connector TasksPhysical Disk TasksTable A-30. Controller Tasks Supported by the PERC Hardware ControllersController Task NamePER

Strany 266 - SAS Controller Conditions

338 Supported FeaturesCancel RebuildYes Yes Yes Yes Yes Yes YesRemove Dead Disk SegmentsNo No No No No No NoFormat Disk No No No No No No NoClear Yes

Strany 267 - Moving the Disks

Supported Features 339Virtual Disk TasksTable A-32. Virtual Disk Tasks Supported by the PERC Hardware ControllersVirtual Disk Task Name PERC H800PERC

Strany 268

34 Getting Started

Strany 269 - Hot Spare

340 Supported FeaturesVirtual Disk SpecificationsCancel Format Virtual DiskNo No No No No NoRestore Dead Disk SegmentsNo No No No No NoInitialize Virt

Strany 270

Supported Features 341Maximum Virtual Disk SizeNone None None None None None NoneMaximum Number of Spans per Virtual Disk 88 8 8 8 8 8Maximum Number o

Strany 271

342 Supported FeaturesMaximum Number of Physical Disks in a RAID 50256 256 256 NA 256 256 16Minimum Number of Physical Disks that Can Be Concatenated

Strany 272

Supported Features 343Supported RAID LevelsMinimum number of physical disks in a RAID 644 4 4 4 4 NAMinimum number of physical disks in a RAID 6088 8

Strany 273

344 Supported FeaturesRead, Write, Cache and Disk Cache PolicyTable A-35. Read, Write, and Cache Policy Supported by the PERC Hardware ControllersRead

Strany 274

Supported Features 345Enclosure SupportSupported Features on the SAS 5/iR, SAS 6/iR, and PERC H200 Controllers This section identifies the controller-

Strany 275

346 Supported Features• Enclosure SupportFor enclosure-supported tasks, see Enclosure and Backplane Features.Controller TasksTable A-37. Controller Ta

Strany 276

Supported Features 347Battery Tasks Connector Tasks Physical Disk TasksTable A-38. Battery Tasks Supported on the SAS 5/iR, SAS 6/iR, and H200 Control

Strany 277 - CacheCade Using Solid State

348 Supported FeaturesVirtual Disk Tasks Prepare to Remove No No NoOffline No No NoOnline No No NoInitialize No No NoRebuild No NA.Rebuild automatical

Strany 278

Supported Features 349Supported RAID LevelsBlink/Unblink Yes Yes YesReconfigure No No NoChange Policy No No YesSplit Mirror NoNoNoUnmirror No No NoDel

Strany 279 - BIOS Terminology

Understanding RAID Concepts 353Understanding RAID Concepts Storage Management uses Redundant Array of Independent Disks (RAID) technology to provide S

Strany 280 - 280 BIOS Terminology

350 Supported FeaturesVirtual Disk SpecificationsRAID 10 No No YesTable A-43. Virtual Disk Specifications for the SAS 5/iR, SAS 6/iR, and PERC H200 Co

Strany 281 - Troubleshooting

Supported Features 351Maximum Number of Physical Disks in a RAID 50NA NA NA Minimum Number of Physical Disks that Can Be Concatenated NA NA NA Minimum

Strany 282 - Isolate Hardware Problems

352 Supported FeaturesRead, Write, Cache and Disk Cache PolicyEnclosure SupportTable A-44. Read, Write, and Cache Policy Supported by the SAS 5/iR, SA

Strany 283 - Replacing a Failed Disk

Supported Features 353Supported Features on the PERC S100, PERC S110, and S300 ControllersThis section identifies the controller-supported features an

Strany 284

354 Supported FeaturesVirtual Disk TasksVirtual Disk SpecificationsTable A-48. Virtual Disk Tasks Supported by the PERC S100, PERC S110, and S300 Cont

Strany 285 - Troubleshooting 285

Supported Features 355Maximum Virtual Disk SizeNone None NoneMaximum Number of Spans per Virtual Disk NA NA NAMaximum Number of Physical Disks per Spa

Strany 286 - Virtual Disk Troubleshooting

356 Supported FeaturesSupported RAID LevelsRead, Write, Cache and Disk Cache PolicyMinimum Number of Physical Disks in a RAID 5333Minimum Number of Ph

Strany 287 - Troubleshooting 287

Supported Features 357Enclosure SupportSupported Features on the Non-RAID ControllersThis section identifies the controller-supported features and whe

Strany 288

358 Supported Features• Virtual Disk Tasks• Enclosure SupportFor enclosure-supported tasks, see Enclosure and Backplane Features.Controller Tasks Tabl

Strany 289 - Virtual Disk Errors on Linux

Supported Features 359Battery Tasks Connector Tasks Physical Disk Tasks Table A-54. Battery Tasks Supported on the Non-RAID ControllersBattery Task Na

Strany 290

36 Understanding RAID Conceptsthe RAID levels. For this reason, using software RAID by itself can slow system performance. You can, however, use softw

Strany 291 - Troubleshooting 291

360 Supported FeaturesVirtual Disk Tasks Cancel Clear No NoTable A-57. Virtual Disk Tasks Supported by the Non-RAID ControllersVirtual Disk Task Name

Strany 292

Supported Features 361Enclosure Support Enclosure and Backplane FeaturesThis section identifies the features supported by the enclosure or backplane.

Strany 293 - “Medium” Error

362 Supported Features• Supported Features on the PERC H700, PERC H710 A, PERC H710 MB, PERC H710 MM, PERC H710P A, PERC H710P MB, and PERC H710P MM C

Strany 294 - Format, or Other Operation

Supported Features 363Enclosure and Backplane Support for Smart Thermal ShutdownTable A-60. Backplane Tasks for SCSI and SAS ControllersBackplane Task

Strany 295 - Troubleshooting 295

364 Supported FeaturesMaximum Supported ConfigurationTable A-62. Backplane Support for Smart Thermal ShutdownSmart Thermal Shutdown SCSI SAS Smart The

Strany 296

Determining the Health Status for Storage Components365BDetermining the Health Status for Storage Components The tables in this appendix indicate how

Strany 297 - PCIe SSD Troubleshooting

366 Determining the Health Status for Storage ComponentsHealth Status Rollup: Physical Disks in a Virtual Disk are Failed or Removed Health Status Rol

Strany 298 - 298 Troubleshooting

Determining the Health Status for Storage Components 367Health Status Rollup: All Physical Disks in a Virtual Disk are in Foreign State HealthRollup T

Strany 299 - Frequently Asked Questions

368 Determining the Health Status for Storage ComponentsHealth Status Rollup: Some Physical Disks in a Virtual Disk are in Foreign State Health Status

Strany 300 - Which Controllers do I Have?

Determining the Health Status for Storage Components 369Health Status Rollup: Virtual Disk is Failed Health RollupTable B-7. Health Status Rollup: Vir

Strany 301 - How do I Turn off an Alarm?

Understanding RAID Concepts 37•Stripe element size—The amount of disk space consumed by a stripe element. For example, consider a stripe that contains

Strany 302

370 Determining the Health Status for Storage ComponentsHealth Status Rollup: Unsupported Firmware Version Health Status Rollup: Enclosure Power Suppl

Strany 303 - Supported Features

Determining the Health Status for Storage Components 371Health Status Rollup: One Enclosure Fan is Failed Health Status Rollup: One Enclosure EMM is F

Strany 304 - 304 Supported Features

372 Determining the Health Status for Storage ComponentsHealth Status Rollup: One Enclosure Temperature Probe is Failed Health Status Rollup: Lost Bot

Strany 305 - Connector Tasks

Determining the Health Status for Storage Components 373Health Status Rollup: One or More Physical Disks are Failed Health RollupNA NA NATable B-14. H

Strany 306 - Physical Disk Tasks

374 Determining the Health Status for Storage ComponentsHealth Status Rollup: Physical Disk is Rebuilding Table B-15. Health Status Rollup: Physical D

Strany 307

38 Understanding RAID Conceptsfault-tolerance is achieved by maintaining redundant data. Redundant data includes mirrors (duplicate data) and parity i

Strany 308 - 308 Supported Features

Understanding RAID Concepts 39• RAID Level 5 (Striping with distributed parity)• RAID Level 6 (Striping with additional distributed parity)• RAID Leve

Strany 309 - Virtual Disk Specifications

4 ContentsCommon Storage Tasks . . . . . . . . . . . . . . . . . 333 Understanding RAID Concepts . . . . . . . 35What Is RAID? . . . . . . . .

Strany 310 - 310 Supported Features

40 Understanding RAID ConceptsFigure 3-1. Concatenating Disks• Concatenates n disks as one large virtual disk with a capacity of n disks.• Data fills

Strany 311

Understanding RAID Concepts 41Figure 3-2. Striping DisksRAID 0 Characteristics: • Groups n disks as one large virtual disk with a capacity of (smalles

Strany 312 - Supported RAID Levels

42 Understanding RAID ConceptsRAID Level 1 (Mirroring) RAID 1 is the simplest form of maintaining redundant data. In RAID 1, data is mirrored or dupli

Strany 313

Understanding RAID Concepts 43Related Information: • Organizing Data Storage for Availability and Performance• Comparing RAID Level and Concatenation

Strany 314

44 Understanding RAID Concepts• When a disk fails, the virtual disk still works, but it is operating in a degraded state. The data is reconstructed fr

Strany 315

Understanding RAID Concepts 45Figure 3-5. RAID 6 RAID 6 Characteristics: • Groups n disks as one large virtual disk with a capacity of (n-2) disks.• R

Strany 316

46 Understanding RAID Concepts• Number of Physical Disks per Virtual Disk• Maximum Number of Virtual Disks per ControllerRAID Level 50 (Striping over

Strany 317

Understanding RAID Concepts 47Figure 3-6. RAID 50 RAID 50 Characteristics: • Groups n*s disks as one large virtual disk with a capacity of s*(n-1) dis

Strany 318

48 Understanding RAID Concepts NOTE: On the PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di controllers, there are special considerations when impleme

Strany 319

Understanding RAID Concepts 49Figure 3-7. RAID 60 RAID 60 Characteristics: • Groups n*s disks as one large virtual disk with a capacity of s*(n-2) dis

Strany 320

Contents 54 Quick Access to Storage Status andTasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Storage Dashboard and Storage Health. .

Strany 321 - Enclosure Support

50 Understanding RAID Concepts• Two disks per span are required for parity. RAID 60 is more expensive in terms of disk space. Related Information: • O

Strany 322 - CERC 6/I Controllers

Understanding RAID Concepts 51Figure 3-8. Striping Over Mirrored Disk GroupsRAID 10 Characteristics: • Groups n disks as one large virtual disk with a

Strany 323

52 Understanding RAID ConceptsRelated Information: • Organizing Data Storage for Availability and Performance• Comparing RAID Level and Concatenation

Strany 324 - 324 Supported Features

Understanding RAID Concepts 53• Controller-supported RAID Levels• Number of Physical Disks per Virtual Disk• Maximum Number of Virtual Disks per Contr

Strany 325

54 Understanding RAID ConceptsTable 3-1. RAID Level and Concatenation Performance Comparison RAID LevelData AvailabilityRead PerformanceWrite Perform

Strany 326

Understanding RAID Concepts 55No-RAIDIn Storage Management, a virtual disk of unknown metadata is considered a No- RAID volume. Storage Management doe

Strany 327

56 Understanding RAID Concepts

Strany 328

Quick Access to Storage Status and Tasks 574Quick Access to Storage Status and Tasks This section describes various methods to determine the status or

Strany 329

58 Quick Access to Storage Status and Tasks• Click the virtual disk that is in degraded state to display the Physical Disk Properties page. NOTE: Th

Strany 330

Quick Access to Storage Status and Tasks 59Table 4-1. Component SeverityStorage Properties and Current Activity The Configuration/Information subtab d

Strany 331

6 ContentsPhysical Device Properties . . . . . . . . . . . . . . . 67Physical Device Tasks. . . . . . . . . . . . . . . . . . 71Blink and Unblink

Strany 332

60 Quick Access to Storage Status and Tasks• Power Supply Properties• Temperature Probe Properties and Tasks• Virtual Disk Properties and TasksAlerts

Strany 333

Quick Access to Storage Status and Tasks 61Using Enclosure Temperature ProbesPhysical disk enclosures have temperature probes that warn you when the e

Strany 334 - 334 Supported Features

62 Quick Access to Storage Status and TasksRelated Information: • I/O and Reboot Requirements for Detecting Physical Disk Status Changes• Time Delay i

Strany 335

Quick Access to Storage Status and Tasks 63healthy. Once the communication path is restored, reboot the system to update the disk status. If the commu

Strany 336

64 Quick Access to Storage Status and Tasks

Strany 337

PCI Express Solid-State Device Support 655PCI Express Solid-State Device SupportThis section gives an overview of the OpenManage Storage Management (O

Strany 338 - 338 Supported Features

66 PCI Express Solid-State Device SupportPCIe Sub System PropertiesThe PCIe SSD sub system comprises of the following components:•Backplane•Extender C

Strany 339

PCI Express Solid-State Device Support 67PCIe Extender CardsThe PCIe Extender Card is attached to the backplane of the system and provides PCIe connec

Strany 340

68 PCI Express Solid-State Device SupportTable 5-3. Physical Device PropertiesProperties DescriptionName Displays the name of the PCIe SSD. The name i

Strany 341

PCI Express Solid-State Device Support 69Device Life Status Displays the life status of the PCIe SSD. The device life status is determined by the foll

Strany 342 - 342 Supported Features

Contents 7RAID Controller Read, Write, Cache, and Disk Cache Policy. . . . . . . . . . . . . . . . . . . . . . . 85Read Policy. . . . . . . . . . .

Strany 343

70 PCI Express Solid-State Device SupportApproaching Read Only — The drive is running out of spare sectors and is reaching the read-only mode. However

Strany 344 - 344 Supported Features

PCI Express Solid-State Device Support 71Physical Device TasksThe physical device tasks for PCIe SSD are as follows:•Blink• Unblink• Full Initializati

Strany 345

72 PCI Express Solid-State Device Support NOTE: If the system reboots or experiences a power loss during full intialization, the operation aborts. Yo

Strany 346

PCI Express Solid-State Device Support 73BackplanesPCIe SSDs are attached to the PCIe SSD backplane of the system. The number of supported PCIe SSDs d

Strany 347

74 PCI Express Solid-State Device Support

Strany 348

Storage Information and Global Tasks 755Storage Information and Global Tasks Use this window to view high-level information about your system’s storag

Strany 349

76 Storage Information and Global TasksGlobal Tasks: • Global Rescan• Enable/Disable Smart Thermal Shutdown• Setting Hot Spare Protection PolicyGlobal

Strany 350

Storage Information and Global Tasks 77If the enclosure has virtual disks that are channel-redundant, then the enclosure can be turned off while redun

Strany 351

78 Storage Information and Global TasksTable 6-2. Controller PropertiesProperty Definition Status This property displays the controller status. ID T

Strany 352

Storage Information and Global Tasks 79Minimum Required Firmware Version This property displays the minimum firmware version that is required by Stora

Strany 353

8 ContentsExport Log . . . . . . . . . . . . . . . . . . . . . . . 108Foreign Configuration Operations. . . . . . . . . . . 109Foreign Configurat

Strany 354

80 Storage Information and Global TasksStorage Components For information on attached controllers, see the following topics: • Controller Properties a

Strany 355

Controllers 817Controllers This section describes the controllers supported by Storage Management as well as the different controller features.What is

Strany 356

82 ControllersRAID Controller Technology: SCSI, SATA, ATA, and SAS Storage Management supports RAID controllers using SCSI, SATA, ATA, and SAS technol

Strany 357

Controllers 83• PERC H200, H700, and H800 controllers• PERC H310 Adapter, PERC H310 Mini Monolithic, PERC H310 Mini Blades, PERC H710 Adapter, PERC H7

Strany 358

84 Controllers•Read, write, and cache policies—The manner in which a controller reads and writes data can vary. The read, write, and cache policies ha

Strany 359

Controllers 85RAID Controller Read, Write, Cache, and Disk Cache Policy When creating a virtual disk, you specify the read, write, and cache policies

Strany 360

86 ControllersWrite Policy Does my controller support this feature? See Supported FeaturesThe write policies specify whether the controller sends a wr

Strany 361

Controllers 87•Write-Through—When using write-through caching, the controller sends a write-request completion signal only after the data is written t

Strany 362 - Enclosure and Backplane Tasks

88 Controllers•Direct I/O—Specifies that reads are not buffered in cache memory. When using direct I/O, data is transferred to the controller cache an

Strany 363

Controllers 89 NOTE: Storage Management does not configure resource ownership in an Microsoft Windows cluster configuration. Updating the Display of

Strany 364 - 364 Supported Features

Contents 9Resizing the CacheCade . . . . . . . . . . . . . . 140Renaming the CacheCade . . . . . . . . . . . . . 140Blinking and Unblinking the Cac

Strany 365 - Storage Components

90 Controllers NOTE: When creating a virtual disk on a controller that is in a cluster configuration, you must specify the maximum virtual disk size.

Strany 366 - Degraded

Controllers 91 NOTE: On replacing a SMART error drive with a good drive on PERC4/IM controllers, it is necessary to perform a rescan operation on the

Strany 367

92 ControllersNon-RAID SAS ControllersThe following non-RAID controllers use Serial Attached SCSI (SAS) technology. • SAS 5/i Integrated • SAS 5/E • S

Strany 368

Controllers 93Table 7-1. Firmware and Driver PropertiesProperty Definition Firmware Version This property displays the version of the firmware that i

Strany 369

94 ControllersController HealthThis screen displays the status of the controller and the components attached to the controller. Controller Severity Co

Strany 370 - Version

Controllers 95Controller Components For information on attached components, see the following topics: • RAID Controller Batteries• Firmware/Driver Ver

Strany 371

96 ControllersController Properties The controller properties can vary depending on the model of the controller. Controller properties may include: Ta

Strany 372 - Connections to the Enclosure

Controllers 97Firmware Version This property displays the version of the firmware that is currently installed on the controller. NOTE: On some contro

Strany 373

98 Controllers Rebuild Rate The rebuild rate is the percentage of the system’s resources dedicated to rebuilding a failed disk when a rebuild is nece

Strany 374

Controllers 99Auto replace member on predictive failureIn case of predictive failure, this property enables the automatic copying of data from a physi