288 omconfig storage Commands
Example Syntax
To blink the physical disk in cachecade 4 on controller 1, type:
omconfig storage cachecade action=blink
controller=1 cachecade=4
omconfig Unblink Cachecade
Use the following omconfig command syntax to unblink the physical disks
included in a cachecade.
Complete Syntax
omconfig storage cachecade action=unblink
controller=id cachecade=id
where id is the controller ID and cachecade ID as reported by the omreport
command. To obtain these values, type omreport storage controller to display
the controller IDs and then type omreport storage cachecade controller=ID
to display the IDs for the cachecades of the controller.
Example Syntax
To unblink the physical disks in cachecade 4 on controller 1, type:
omconfig storage cachecade action=unblink
controller=1 cachecade=4
omconfig Delete Cachecade
Use the following omconfig command syntax to delete a cachecade.
Complete Syntax
omconfig storage cachecade action=deletecachecade
controller=id cachecade=id
where id is the controller ID and cachecade ID as reported by the omreport
command. To obtain these values, type omreport storage controller to display
the controller IDs and then type omreport storage cachecade controller=ID
to display the IDs for the cachecades of the controller.