Dell OpenManage Server Administrator Version 5.5 Uživatelská příručka Strana 663

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 758
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 662
Traps 663
Table 26-2. Miscellaneous Traps
Trap
ID
Description Severity Cause
System Up
1001 Server
Administrator
startup complete
Information Server Administrator completed its
initialization.
Thermal Shutdown
1004 Thermal shutdown
protection has
been initiated
Error This message is generated when a
system is configured for thermal
shutdown due to an error event. If a
temperature sensor reading exceeds
the error threshold for which the
system is configured, the operating
system shuts down and the system
powers off. This event may also be
initiated on certain systems when a fan
enclosure is removed from the system
for an extended period of time.
Automatic System Recovery
1006 Automatic System
Recovery (ASR)
action was
performed
Action performed
was:
<Action>
Date and time of
action:
<Date and
time>
Error This message is generated when an
automatic system recovery action is
performed due to a hung operating
system. The action performed and
the date and time of the action are
provided.
Host System Reset
1007 User initiated
host system
control action
Action requested
was:
<Action>
Information User requested a host system control
action to reboot, power off, or power
cycle the system or another event
such as thermal shutdown protection
initiated a power off, operating
system shutdown.
book.book Page 663 Tuesday, August 5, 2008 9:15 AM
Zobrazit stránku 662
1 2 ... 658 659 660 661 662 663 664 665 666 667 668 ... 757 758

Komentáře k této Příručce

Žádné komentáře