omconfig storage Commands 249
Example for SCSI, SATA, and ATA Controllers
In this example, temperature probe 3 resides in the enclosure attached to
connector 2 on controller 1. To reset the thresholds for temperature probe 3
to the default values, type:
omconfig storage enclosure action=resettempprobes
controller=1 enclosure=2 index=3
omconfig Set All Temperature Probe Thresholds
Use the following omconfig command syntax to set the minimum and
maximum warning temperature thresholds for all temperature probes in the
enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=setalltempprobes
controller=id enclosure=<ENCLOSUREID> minwarn=n
maxwarn=n
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Example Syntax
For example, you may want to specify the minimum and maximum warning
thresholds for all temperature probes to 10 and 40
° Celsius.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to
connector 2 on controller 1. To set the thresholds for all temperature probes
to 10 and 40
° Celsius, type:
omconfig storage enclosure action=setalltempprobes
controller=1 enclosure=2:3 minwarn=10 maxwarn=40