Dell PowerEdge 2650 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Dell PowerEdge 2650. Dell PowerEdge 2650 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 65
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Dell™PowerEdge™2650SystemsServiceManual
System Overview
Basic Troubleshooting
Indicators, Codes, and Messages
Removing and Replacing Parts
Jumpers and Connectors
Using the System Setup Program
Notes, Notices, and Cautions
Information in this document is subject to change without notice.
©2002DellComputerCorporation.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Computer Corporation; Intel is a registered trademark and Xeon is a
trademark of Intel Corporation; Microsoft, MS-DOS, Windows NT, and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation
disclaims any proprietary interest in trademarks and trade names other than its own.
Initial release: 24 Apr 2002
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Zobrazit stránku 0
1 2 3 4 5 6 ... 64 65

Shrnutí obsahu

Strany 1

Dell™PowerEdge™2650SystemsServiceManual System Overview Basic Troubleshooting Indicators, Codes, and Messages Removing and Replacing Parts Jumper

Strany 2 - Basic Troubleshooting

NIC Indicator Codes Each NIC on the back panel has an indicator that provides information on network activity and link status (see Figure3-6). Table

Strany 3 - Internal Visual Inspection

Line 1 Message Line 2 Message Causes Corrective Actions SYSTEM ID SYSTEM NAME SYSTEM ID is a unique name, five characters or less, defined by the us

Strany 4

E07FA TEMP CPU n THERM Specified microprocessor is out of acceptable temperature range and is operating at a reduced speed, or frequency. Ensure tha

Strany 5

Solving Problems Described by LCD Status Messages When a single message appears on the status LCD, locate the code in Table3-9 and perform the sugge

Strany 6 - System-Status Indicators

Diskette read failure Faulty or improperly inserted diskette. Replace the diskette. Diskette subsystem reset failed Faulty or improperly installed d

Strany 7

System Beep Codes When an error that cannot be reported on the monitor occurs during a boot routine, the system may emit a series of beeps that identi

Strany 8 - Power Indicator Codes

Warning Messages A warning message alerts you to a possible problem and asks you to take corrective action before the system continues a task. For exa

Strany 9 - Hard-Drive Indicator Codes

Diagnostics Messages When you run a test group or subtest in system diagnostics, an error message may result. Diagnostic error messages are not covere

Strany 10 - LCD Status Messages

Back to Contents Page System Overview Dell™PowerEdge™2650SystemsServiceManual System Features Supported Operating Systems Service Feature

Strany 11

l Back-panel connectors including video, keyboard, mouse, two serial, two USB, embedded remote access Ethernet, and two NICs. l Front-panel connecto

Strany 12

Back to Contents Page Basic Troubleshooting Dell™PowerEdge™2650SystemsServiceManual Initial User Contact External Visual Inspection Obser

Strany 13 - System Messages

Other Documents You May Need Besides this document, the following documentation is included with your system: l The Setting Up Your System document pr

Strany 14

    NIC two RJ45 connectors for integrated 10/100/1000 NICs Embedded remote access Ethernet one RJ45 connector for integrated remote access card (

Strany 15 - System Beep Codes

Back to Contents Page  Operating –16 to 3,048 m (–50 to 10,000 ft.) Storage –16 to 10,600 m (–50 to 35,000 ft)

Strany 16 - Warning Messages

Back to Contents Page Jumpers and Connectors Dell™PowerEdge™2650SystemsServiceManual Jumpers—AGeneralExplanation System Board Jumpers S

Strany 17 - Alert Messages

System Board Connectors See Figure5-3 and Table5-2 for the location and description of system board connectors. Figure 5-3. System Board Connecto

Strany 18 - System Overview

Expansion-Card Riser-Board Components and PCI Buses Figure5-4 shows the components on the expansion-card riser board, including the expansion-card

Strany 19 - Power Protection Devices

SCSI Backplane Board Connectors Figure5-5 shows the location of the connectors on the SCSI backplane board. Figure 5-5. SCSI Backplane Board Componen

Strany 20 - Technical Specifications

Back to Contents Page Removing and Replacing Parts Dell™PowerEdge™2650SystemsServiceManual The procedures in this guide require that you remov

Strany 21

Bezel The bezel has a system status indicator. A lock on the bezel restricts access to the power button, diskette drive, CD drive, hard drive(s), an

Strany 22

1. Remove the bezel (see "Removing the Bezel"). 2. Loosen the three thumbscrews that secure the cover to the chassis (see Figure4-3).

Strany 23 - Jumpers and Connectors

Observing the Boot Routine After you have performed an external visual inspection, boot the system and, while the boot routine is running, observe the

Strany 24 - System Board Connectors

Control-Panel Cable Cover The control-panel cable cover shields the cable connected between the control panel board and the SCSI backplane board. Remo

Strany 25

Replacing the Front-Panel I/O Board 1. Lower the front-panel I/O board into the system and align the I/O board connector with the control panel bo

Strany 26 - Back to Contents Page

Replacing the Control Panel 1. Lower the control-panel assembly into the system. 2. Connect the control-panel cable to the control panel board

Strany 27 - System Orientation

Replacing a Cooling Fan 1. Lower the fan into the retention base until the fan snaps into position (see Figure4-8). 2. Replace the cover (see

Strany 28 - System Cover

Replacing the System-Fan Bracket 1. Replace the system-fan bracket (see Figure4-9): a. Lower the bracket into the chassis, hooking the top bra

Strany 29 - Inside the System

Replacing a Power Supply 1. With the power-supply handle in the extended position, slide the new power supply into the chassis (see Figure4-10).

Strany 30 - Front-Panel I/O Board

Replacing the Expansion-Card Cage 1. With the expansion-card cage lever in the upright position, carefully lower the cage into the chassis until it

Strany 31 - Control Panel

Installing an Expansion Card 1. Unpack the expansion card, and prepare it for installation. For instructions, see the documentation accompanying t

Strany 32 - System Fans

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Remove the cover (see "R

Strany 33 - System-Fan Bracket

Replacing the Expansion-Card Riser Board 1. Replace the expansion-card riser board (see Figure4-13): a. Align the riser board with the expansi

Strany 34 - Power Supplies

1. Remove the bezel (see "Removing the Bezel"). 2. Turn off the system, including any attached peripherals, and disconnect all the power

Strany 35 - Expansion-Card Cage

Performing a Memory Upgrade 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. 

Strany 36 - Expansion Cards

5. Align the memory module's edge connector with the alignment key, and insert the memory module in the connector (see Figure4-14). The memor

Strany 37 - Removing an Expansion Card

2. Press the CD/diskette drive tray release handle until the tray snaps into place (see Figure4-15). 3. Reconnect your system and peripherals to

Strany 38 - Expansion-Card Riser Board

c. Press the cable securing latch into the locked position. 3. Install the CD drive on the drive tray (see Figure4-16): a. Lower the left side

Strany 39 - Memory Modules

4. Replace the CD/diskette drive tray (see "Replacing the CD/Diskette Drive Tray"). SCSI Configuration Information Although SCSI devices

Strany 40 - Installing Memory Modules

The hard-drive bays provide space for up to five 1-inch SCSI hard drives. The hard drives connect to a controller on the system board or a RAID contro

Strany 41 - CD and Diskettes Drives

1. Remove the bezel (see "Removing the Bezel"). 2. If your replacement hard drive does not have a carrier, install the new drive on a ca

Strany 42

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Remove the cover (see "R

Strany 43

11. Replace the cover (see "Replacing the Cover"). 12. Reconnect the system to its electrical outlet and turn the system on, including

Strany 44 - Hard Drives

SCSI Backplane Daughter Card To operate the SCSI backplane in a split backplane configuration, you must install a daughter card. In a split backplane

Strany 45 - Installing a Hard Drive

provided to assist you. For more information on these help tools, see "Getting Help" in your Installation and Troubleshooting Guide. Back to

Strany 46 - Integrated RAID Controller

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Pull the retention lever to s

Strany 47

1. Lower the backplane board into the system board tray. 2. Connect the control-panel cable to the SCSI backplane board (see Figure4-5). 3. Al

Strany 48 - RAID Controller Card

5. Lift the front of the system board tray upward slightly and then pull the tray straight back until it clears the chassis. Replacing the System

Strany 49 - SCSI Backplane Daughter Card

To take advantage of future options in speed and functionality, you can add a second microprocessor or replace either the primary or secondary micropr

Strany 50 - SCSI Backplane Board

4. Pull the socket release lever upward to the fully open position (see Figure4-28). 5. Lift the microprocessor out of the socket and leave the

Strany 51 - System Board Tray

13. Hook the end of the clips without the latch to the tab on the edge of the socket. 14. Push down and pivot the securing clip latch until the h

Strany 52 - Microprocessors

4. Remove the system battery (see Figure4-30). See Figure5-3 to locate the system battery on the system board. You can pry the system battery out

Strany 53

Replacing the System Board 1. Replace the system board (see Figure4-31): a. Lower the front of the system board into the system board tray, un

Strany 54

Back to Contents Page Using the System Setup Program Dell™PowerEdge™2650SystemsServiceManual Entering the System Setup Program System Setup

Strany 55 - System Battery

help area), the changes take effect immediately. System Setup Options The following subsections outline the options on the System Setup screens. Main

Strany 56 - System Board

Back to Contents Page Indicators, Codes, and Messages Dell™PowerEdge™2650SystemsServiceManual The system indicators and features are illustrat

Strany 57 - Replacing the System Board

l PCIX Slot Information — Displays a menu that contains information about each of the system's PCI-X slots. l Console Redirection — Displays a

Strany 58

l Setup Password — Allows you to restrict access to the System Setup program in the same way that you restrict access to your system with the system p

Strany 59 - System Setup Options

3. Type your new system password. You can use up to 32 characters in your password. As you press each character key (or the spacebar for a blank sp

Strany 60 - System Security Screen

Using the Setup Password Feature Your system is shipped to you without the setup password feature enabled. If system security is a concern, you should

Strany 61 - Assigning a System Password

9. Replace the cover (see "Replacing the Cover"). 10. Reconnect your system and peripherals to their electrical outlets, and turn on the

Strany 62

Back to Contents Page Dell™PowerEdge™2650SystemsServiceManual Information in this document is subject to change without notice. ©2002DellCom

Strany 63 - Assigning a Setup Password

Additional indicators are located behind the bezel. The front-panel status LCD provides information using an alphanumeric character display (see "

Strany 64

Power Indicator Codes The system has indicators on the front panel and the power supplies that signify system power status. Power-Button Indicator

Strany 65

Hard-Drive Indicator Codes Each hard-drive carrier has two indicators: a busy indicator and a status indicator (see Figure3-5). The indicators pro

Komentáře k této Příručce

Žádné komentáře