Dell PowerEdge VRTX Chassis Management Controller FirmwareEvent Message Reference Guide Version 1.0
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertE
SubCategory CBL = CableSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Visibil
Detailed DescriptionNoneRecommended Response ActionCheck backplane configuration. Re-connect cable. If the issue persists, contact technical support.
Arguments•arg1 = Bay IDDetailed DescriptionThis is an unsupported backplane configuration.Recommended Response ActionReview product documentation. Che
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE104
7CMC Event MessagesCMC8501Message Chassis Group Leader has synchronized this members configuration.Detailed DescriptionMulti Chassis Management featur
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
SubCategory CMC = Chassis Management ControllerSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial
SubCategory CMC = Chassis Management ControllerSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defau
ENC18...
Detailed DescriptionThis happens during promotion of extended storage feature from single CMC to dual CMC. If the media on Standby CMC is not healthy,
CMC8512Message The Extended Storage feature activation timed out. The feature is not active.Detailed DescriptionThe Extended Storage feature is not ac
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRe
SubCategory CMC = Chassis Management ControllerSeverity Severity 2 (Warning)Trap/EventID 2546LCD Message No LCD message display defined.Initial Defaul
Recommended Response ActionDo the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait for the CMC to complete the s
Detailed DescriptionFRU on the server specified in the message is not functioning or CMC is unable to read it.Recommended Response ActionDo the follow
Detailed DescriptionThe Mezz card 2 FRU for the server specified in the message is not functioning or CMC is unable to read it.Recommended Response Ac
Detailed DescriptionThe Mezz card 4 FRU for the server specified in the message is not functioning or CMC is unable to read it.Recommended Response Ac
Detailed DescriptionCMC is unable to obtain the CPU information from the server specified in the message. This occurs if there is no communication bet
Detailed DescriptionCMC is unable to obtain the link tuning information for the newly installed hardware (server, Input Output Module, or Mezzanine ca
FCD8503...
Arguments•arg1 = sleeve numberDetailed DescriptionThe user account does not have sufficient privileges to perform virtual reseat operation on the slee
CMC8534Message Unable to turn on the serverarg1because the power requirement request exceeds the power cap value.Arguments•arg1 = slot numberDetailed
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSECMC8538Message
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSECMC8540Messa
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Ale
Category AuditSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display define
Category AuditSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display define
Recommended Response ActionNo response action is required.Category AuditSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)T
SubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
HWC4014...
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Ale
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRe
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
138
8CPU Event MessagesCPU0000Message CPUarg1has an internal error (IERR).Arguments•arg1 = numberDetailed DescriptionSystem event log and OS logs may indi
HWC1014...
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
SubCategory CPU = ProcessorSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Vis
Recommended Response Action1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the process
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory CPU = ProcessorSeverity Severity 3
Arguments•arg1 = numberDetailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory CPU = Proce
CPU0024Message CPUarg1is enabled.Arguments•arg1 = numberDetailed DescriptionNoneRecommended Response ActionNo response action is required.Category Sys
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0025Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message CPU <number> voltage regulator module absent. Check moduleInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
IOV116...
Category System HealthSubCategory CPU = ProcessorSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Lost power input for CPU <number> v
Recommended Response Action1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the process
Arguments•arg1 = numberDetailed DescriptionSystem performance may be degraded or the system may fail to operate.Recommended Response ActionReview prod
CPU0700Message CPUarg1initialization error detected.Arguments•arg1 = numberDetailed DescriptionSystem BIOS was unable to boot the processor.Recommende
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0702Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0704Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0011Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
158
9CPUA Event MessagesCPUA0023Message CPUarg1is absentArguments•arg1 = numberDetailed DescriptionNoneRecommended Response ActionVerify processor install
LC056...
160
10CTL Event MessagesCTL1Message Controller event log:arg1Arguments•arg1 = messageDetailed DescriptionThis event is retrieved from the controller when
Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Severity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilt
SubCategory CTL = Storage ContrSeverity Severity 2 (Warning)Trap/EventID 4330LCD Message No LCD message display defined.Initial Default. SNMP Alert;#L
Category StorageSubCategory CTL = Storage ContrSeverity Severity 2 (Warning)Trap/EventID 4330LCD Message No LCD message display defined.Initial Defaul
Recommended Response ActionNo response action is required.Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/Event
Detailed DescriptionThe controller and attached enclosures are not cabled correctly.Recommended Response ActionRefer to the storage hardware documenta
Arguments•arg1 = Controller nameDetailed DescriptionThe controller memory is malfunctioning.Recommended Response ActionReplace the controller, contact
CTL17Messagearg1arg2is changed toarg3.Arguments•arg1 = Controller Name•arg2 = propertyname•arg3 = new valueDetailed DescriptionThis alert is provided
LIC208...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL19Message Abo
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Severity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilt
SubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Al
Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial
Recommended Response ActionRe-issue the command.Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/EventID 4331LCD
Detailed DescriptionThis is the result of a user operation.Recommended Response ActionNo response action is required.Category StorageSubCategory CTL =
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
MEM0021...
Detailed DescriptionThe patrol read task ended.Recommended Response ActionNo response action is required.Category StorageSubCategory CTL = Storage Con
Detailed DescriptionAn error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculate
CTL42Message Enclosure Management Module (EMM) hot plug is not supported onarg1.Arguments•arg1 = Controller nameDetailed DescriptionAn attempt to hot
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL44Message Dia
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Severity Severity 1 (Critical)Trap/EventID 4329LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vi
Recommended Response ActionNo response action is required as the controller is taking the required corrective action. However, If this message is gene
Detailed DescriptionThe text for this message is generated by the controller during runtime and can vary depending on the situation.Recommended Respon
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
Arguments•arg1 = Controller name•arg2 = argsDetailed DescriptionThe text for this alert is generated by the controller and can vary depending on the s
MEM1012...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL57Message The
Trap/EventID 4329LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Recommended Response ActionNo response action is required.Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/Event
Detailed DescriptionPhysical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state during the next system reboot. Th
Arguments•arg1 = args•arg2 = Controller nameDetailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo respon
CTL66Message Attempted to import Unsupported Virtual Disk type RAIDarg1onarg2.Arguments•arg1 = args•arg2 = Controller nameDetailed DescriptionThis ale
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL68Message Att
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
PCI1344...
Severity Severity 2 (Warning)Trap/EventID 4330LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial
Recommended Response ActionReplace the controller with a supported controller.Category StorageSubCategory CTL = Storage ContrSeverity Severity 2 (Warn
Detailed DescriptionThe controller experienced a problem during statup. The message from the controller is recorded in the Lifecycle Log.Recommended R
Detailed DescriptionThe management controller cannot communicate with the storage controller. This may be due to a loss of functionality in the PCIe s
Arguments•arg1 = controller nameDetailed DescriptionThe controller experienced a PCIe training error and is operating at less than full bandwith. User
206
11DKM Event MessagesDKM1000Message A network problem detected. Cannot contact key management server.Detailed DescriptionNoneRecommended Response Actio
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEDKM1002Mess
DKM1006Message Key management server error detected.Detailed DescriptionNoneRecommended Response ActionReview server error logs for additional informa
PDR9...
210
12ENC Event MessagesENC40Message A new enclosure was detected onarg1.Arguments•arg1 = controller nameDetailed DescriptionThe controller detected a new
Severity Severity 3 (Informational)Trap/EventID 4339LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilt
Category StorageSubCategory ENC = Storage EnclosrSeverity Severity 1 (Critical)Trap/EventID 4337LCD Message No LCD message display defined.Initial Def
Recommended Response ActionIdentify and replace the failed component. To identify the failed component, select the enclosure in the tree view and clic
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEENC7Message Thea
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Trap/EventID 4339LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Recommended Response ActionRemove the extra enclosures. Refer to the storage hardware documentation for maximum number of enclosures that can be conne
PDR52...
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
Detailed DescriptionThe controller has lost communication with an Enclosure Management Module (EMM). The cables may be loose or defective.Recommended
Arguments•arg1 = Enclosure elements nameDetailed DescriptionA device has been removed and the system is no longer functioning in optimal condition.Rec
ENC23Messagearg1Bad PHYarg2Arguments•arg1 = Enclosure Name•arg2 = argsDetailed DescriptionThere is a problem with a physical connection or PHY.Recomme
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEENC25Messagearg1
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
Severity Severity 2 (Warning)Trap/EventID 4338LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
SubCategory ENC = Storage EnclosrSeverity Severity 3 (Informational)Trap/EventID 4339LCD Message No LCD message display defined.Initial Default. SNMP
Recommended Response ActionNo response action is required.Category StorageSubCategory ENC = Storage EnclosrSeverity Severity 3 (Informational)Trap/Eve
13FAN Event MessagesFAN8500Message Enhanced Cooling Mode is EnabledDetailed DescriptionEnabling Enhanced Cooling Mode will provide increased airflow c
PDR100...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEFAN8502Mess
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Severity Severity 1 (Critical)Trap/EventID 2153LCD Message Fan <number> RPM is outside of range. Check fan.Initial Default. LC LogFilter Visibil
Category System HealthSubCategory FAN = Fan EventSeverity Severity 1 (Critical)Trap/EventID 2153LCD Message Fan <number> RPM is outside of range
Recommended Response ActionNo response action is required.Category System HealthSubCategory FAN = Fan EventSeverity Severity 3 (Informational)Trap/Eve
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory FAN = Fan EventSeverity Severity 3
Detailed DescriptionThe fan may be required for optimal performance.Recommended Response ActionIf unintentional, install a fan.Category System HealthS
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory FAN = Fan EventSeverity Severity 3
Detailed DescriptionThe cooling device is not performing optimally. The cooling device may be installed improperly or may be failing.Recommended Respo
PST0131...
240
14FCD Event MessagesFCD8500Message Unable to apply thearg1configuration. The affected servers (slotarg2) are not turned off.Arguments•arg1 = configura
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Ale
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNM
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Ale
15HWC Event MessagesHWC8502Message The KVM interconnect is connected.Detailed DescriptionThe KVM cable is connected.Recommended Response ActionNo resp
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEHWC8503Message T
HWC8505Message Control panel firmware updatearg1completeArguments•arg1 = versionDetailed DescriptionThe control panel firmware has been updatedRecomme
HWC1001Message Thearg1is absent.Arguments•arg1 = nameDetailed DescriptionThe absent device may be necessary for proper operation. System functionality
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC1002Mess
PSU1010...
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC1006Mess
HWC2000Message Thearg1cable or interconnect is connected.Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionNo response action is
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEHWC2002Message
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FAL
LCD Message System board <name> cable or interconnect failure. Check connectionInitial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmai
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC1010Mess
HWC3000Message Thearg1is removed.Arguments•arg1 = nameDetailed DescriptionThe removed device may be necessary for proper operation. System functionali
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEHWC2006Message
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU0080...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC4002Mess
HWC4010Message Hardware successfully updated for mezzanine cardarg1.Arguments•arg1 = numberDetailed DescriptionNoneRecommended Response ActionNo respo
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC4012Mess
HWC4014Message Link Tuning data successfully updated.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System
Arguments•arg1 = numberDetailed DescriptionThe fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into
HWC2010Message The riser board cable or interconnect is connected.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Ca
Detailed DescriptionThe USB cable may be necessary for proper operation. System functionality may be degraded.Recommended Response ActionIf removal wa
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory HWC = Hardware ConfigSeverity Seve
Detailed DescriptionThe fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric
Arguments•arg1 = nameDetailed DescriptionCMC has old firmware and does not recognize the new device which has requested link tuning information. After
PWR8530...
HWC5008Message Console is not available for thearg1.Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionContact technical support.
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEHWC5012Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Trap/EventID 2331LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 1 (Critical)Trap/EventID 2329LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
SubCategory HWC = Hardware ConfigSeverity Severity 3 (Informational)Trap/EventID 2331LCD Message No LCD message display defined.Initial Default. LC Lo
Category System HealthSubCategory HWC = Hardware ConfigSeverity Severity 3 (Informational)Trap/EventID 2331LCD Message No LCD message display defined.
Recommended Response ActionReview System Log or front panel for additional information.Category System HealthSubCategory HWC = Hardware ConfigSeverity
Detailed DescriptionServer <number> health changed to a non-recoverable state from a less severe state.Recommended Response ActionReview System
PWR8575...
Detailed DescriptionServer <number> health changed to a critical state from a non-recoverable state.Recommended Response ActionReview System Log
Detailed DescriptionInformation and status from the controller is unavailable.Recommended Response ActionRemove and reapply input power. If problem pe
Detailed DescriptionInformation and status from the controller is unavailable.Recommended Response ActionRemove and reapply input power. If problem pe
Detailed DescriptionInformation and status from the controller is unavailable.Recommended Response ActionRemove and reapply input power. If problem pe
Detailed DescriptionThe mezzanine card may be necessary for proper operation. System functionality may be degraded.Recommended Response ActionIf remov
Detailed DescriptionThe system has detected a mezzanine card that is not supported on this system.Recommended Response Action1) Review system document
Arguments•arg1 = name•arg2 = numberDetailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory
HWC2013Message Fabric mismatch corrected on fabricarg1with server in slotarg2.Arguments•arg1 = name•arg2 = numberDetailed DescriptionNoneRecommended R
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEHWC2015Message
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
PWR0105...
Severity Severity 1 (Critical)Trap/EventID 2329LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
16IOV Event MessagesIOV000Message Successfully completed the operation.Detailed DescriptionThis operation was successful.Recommended Response ActionNo
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV002Messag
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV004Messag
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV006Messag
IOV008Message Chassis manager was unable to put PCIe subsystem into factory modeDetailed DescriptionChassis manager was unable to put PCIe subsystem i
Arguments•arg1 = device name•arg2 = slot type•arg3 = slot numberDetailed DescriptionThe Chassis manager has detected the presence of an adapter card i
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEIOV103Message P
Severity Severity 2 (Warning)Trap/EventID 2554LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC LogFilter V
Detailed DescriptionThe Chassis manager is unable to power on adapter. Possible reasons for power failures are: 1. Adapter not a approved by Dell and
Contents1 Introduction...
RDU8501...
IOV108Message Power fault detected on PCIE devicearg1inarg2arg3.Arguments•arg1 = device name•arg2 = slot type•arg3 = slot numberDetailed DescriptionTh
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV011Messag
IOV013Message A server may only be assigned one and only one VA.Detailed DescriptionA server may not have more than one VA assigned.Recommended Respon
Detailed DescriptionSuccessfully updated chassis infrastructure firmware.Recommended Response ActionNo resposne action is required.Category System Hea
Category System HealthSubCategory IOV = IO VirtualizationSeverity Severity 1 (Critical)Trap/EventID 2553LCD Message No LCD message display defined.Ini
Recommended Response ActionNo response action is required.Category ConfigurationSubCategory IOV = IO VirtualizationSeverity Severity 3 (Informational)
Detailed DescriptionThe discovery process for PCIE adapters was unable to allocate the power required to power on the PCIE adaptersRecommended Respons
IOV118Message IOV Fabricarg1is downArguments•arg1 = Fabric IDDetailed DescriptionIOV Fabric B or C is not up.Recommended Response ActionPower cycle th
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEIOV120Messagearg
Initial Default. SNMP Alert;#LCD;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE
33 RFL Event Messages...649RFL2000...
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail Aler
Trap/EventID 2555LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNM
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV1002Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV1004Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV1006Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEIOV1008Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE316
17JCP Event MessagesJCP8501Message Job ID:arg1. CMC sentarg2ofarg3arg4profilesarg5arg6properties to the server (Service Tag:arg7) in the slotarg8.Argu
Recommended Response ActionRetry the update and schedule the update job.Category ConfigurationSubCategory JCP = Job ControlSeverity Severity 2 (Warnin
SubCategory JCP = Job ControlSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFil
37 SEC Event Messages...671SEC0001...
SubCategory JCP = Job ControlSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Vi
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP Alert
SubCategory JCP = Job ControlSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Vi
SubCategory JCP = Job ControlSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Vi
Recommended Response ActionOne of the job ID values specified as input is duplicated. Remove the duplicated Job ID from the operation input parameters
18LC Event MessagesLC054Message Unable to write to the network share.Detailed DescriptionThe network share may be read-only or it may not have suffici
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELC056Messag
LC058Message Invalid AttributeValue parameter value for corresponding AttributeName value,arg1.Arguments•arg1 = AttributeNameDetailed DescriptionThe a
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELC0100Messa
LC060Message Lifecycle controller is currently not ready to take provisioning requestsDetailed DescriptionLifecycle controller is currently performing
SEL0004...
Detailed DescriptionExport or Import server profile operation is already running. The operation may take a few minutes to compete.Recommended Response
Detailed DescriptionThe maximum number of characters allowed for the parameter is displayed.Recommended Response ActionReduce the number of characters
332
19LIC Event MessagesLIC501Message A required license is missing or expired.Detailed DescriptionThe attempted action requires a valid license for certa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC503Messa
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC007Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC009Messa
SEL1504...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC011Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC013Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC015Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC017Messa
LIC019Message A leased license may not be imported prior to its start date.Detailed DescriptionA leased license may not be imported prior to the actua
LIC021Message Import failed: The features contained in the evaluation license are already licensed.Detailed DescriptionAll the features in the evaluat
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC203Messa
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRe
Trap/EventID 8515LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilter VisibilityIPMI A
SubCategory LIC = LicensingSeverity Severity 3 (Informational)Trap/EventID 8515LCD Message No LCD message display defined.Initial Default. SNMP Alert;
STOR032...
Trap/EventID 8515LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilter VisibilityIPMI A
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC901Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC903Messa
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELIC905Messa
LIC907Message Unable to perform the operation due to an unknown error in iDRAC.Detailed DescriptionThe operation failed to execute due to an unknown e
20LNK Event MessagesLNK8500Message Network link to servers in slotarg1IOMarg2portarg3is downArguments•arg1 = slot id•arg2 = iom id•arg3 = port idDetai
Category System HealthSubCategory LNK = Link StatusSeverity Severity 3 (Informational)Trap/EventID 2251LCD Message No LCD message display defined.Init
Recommended Response ActionNo response action is required.Category System HealthSubCategory LNK = Link StatusSeverity Severity 3 (Informational)Trap/E
358
21LOG Event MessagesLOG004Message Resource allocation failure.Detailed DescriptionThe operation failed due to lack of memory or file space in iDRAC.Re
SUP023...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSELOG300Messa
LOG303Message Unable to archive the Chassis Log file.Detailed DescriptionUnable to rename current Chassis Log file during archive operation. Some log
Arguments•arg1 = log entry countDetailed DescriptionThis message is generated after a series of sequential duplicate events. Log entry count is the nu
22MEM Event MessagesMEM8500Message Low memory condition detected.Detailed DescriptionA low memory condition was detected. If this condition continues,
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message Multi-bit memory error on <location>. Reseat memoryInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
SubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter V
SWC8531...
Category System HealthSubCategory MEM = MemorySeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defaul
Recommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventI
Detailed DescriptionSystem performance is degraded.Recommended Response ActionIf unexpected, review system logs for power or thermal exceptions.Catego
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
Detailed DescriptionNoneRecommended Response ActionRe-install the memory component. If the problem continues, contact support.Category System HealthSu
Category System HealthSubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial
Recommended Response ActionReview system logs for memory exceptions. Re-install memory at location <location>Category System HealthSubCategory M
Recommended Response ActionReview system logs for memory exceptions. Re-install memory at location <location>Category System HealthSubCategory M
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
Detailed DescriptionThe memory may not be operational. This an early indicator of a possible future uncorrectable error.Recommended Response ActionRe-
SWU8520...
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
Category System HealthSubCategory MEM = MemorySeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Memory riser mismatch detected. Check memory
Recommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventI
SubCategory MEM = MemorySeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Visibi
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
SubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter V
Category System HealthSubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial
Recommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (Informational)Trap/EventI
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
SYS006...
Detailed DescriptionNoneRecommended Response ActionRe-install the memory component. If the problem continues, contact support.Category System HealthSu
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory MEM = MemorySeverity Severity 3 (I
Detailed DescriptionThe memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.Recommended Response ActionRe-install
23OSE Event MessagesOSE0000Message A critical stop occurred during OS load.Detailed DescriptionThe system halted due to an exception during operating
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEOSE0002Mess
OSE0004Message A soft shut-down initiated by platform event filter.Detailed DescriptionA separate exception or status condition shutdown the operating
Detailed DescriptionThe system OS has successfully booted from A:Recommended Response ActionNo response action is required.Category System HealthSubCa
Category System HealthSubCategory OSE = OS EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initia
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEOSE1007Mess
ASR0102...
TMP0121...
OSE1009Message Failed to boot from CD-ROM.Detailed DescriptionNoneRecommended Response ActionReview system boot configuration and boot media. Verify t
Detailed DescriptionNoneRecommended Response ActionCheck system event logs for additional exception information. Power down the system and attempt to
Category System HealthSubCategory OSE = OS EventSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Def
24PCI Event MessagesPCI1300Message A front panel diagnostic interrupt was detected.Detailed DescriptionThe front panel diagnostic was pressed, and the
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP Aler
Recommended Response ActionCycle input power, update component drivers, if device is removable, re-install the device.Category System HealthSubCategor
Detailed DescriptionSystem performance may be degraded.Recommended Response ActionCycle input power, update component drivers, if device is removable
PCI1318Message A fatal error was detected on a component at busarg1devicearg2functionarg3.Arguments•arg1 = bus•arg2 = device•arg3 = funcDetailed Descr
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR6...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPCI1346Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Trap/EventID FALSELCD Message Fatal error on slot <number>. Reseat PCI cardInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail Ale
SubCategory PCI = PCI DeviceSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Vis
Recommended Response ActionCycle input power, update component drivers, remove and re-install the device.Category System HealthSubCategory PCI = PCI D
Detailed DescriptionSystem performance may be degraded, or system may fail to operate.Recommended Response ActionCycle input power, update component d
Detailed DescriptionEither the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support FlexAddress.Recommended Response ActionUpdate BIOS
Detailed DescriptionEither the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress.Recommended Response ActionUpdate
PCI3004Message Device option ROM on mezzanine cardarg1failed to support Link Tuning or FlexAddress.Arguments•arg1 = numberDetailed DescriptionEither t
VDR48...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPCI3006Mess
PCI3008Message A non-fatal PCIe error detected on a component at busarg1devicearg2functionarg3.Arguments•arg1 = bus•arg2 = device•arg3 = funcDetailed
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
SubCategory PCI = PCI DeviceSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilt
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE426
25PDR Event MessagesPDR1Messagearg1copyback stopped for rebuild.Arguments•arg1 = physical diskDetailed DescriptionThis message is generated after a co
Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
SubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID 4347LCD Message No LCD message display defined.Initial Default. SNMP Al
VLT0300...
Detailed DescriptionA physical disk in the virtual disk is offline. This may have been user initiated.Recommended Response ActionForce the physical di
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
Detailed DescriptionThis message is generated after a rebuild starts on a physical disk.Recommended Response ActionNo response action is required.Cate
Detailed DescriptionThe physical disk has failed or is corrupt.Recommended Response ActionReplace the failed or corrupt disk. Identify a disk that has
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
Detailed DescriptionThe physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). Whe
Arguments•arg1 = PD NameDetailed DescriptionA physical disk assigned as a hot spare was unassigned and is no longer functioning as a hot spare. The ph
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR20Message SMA
Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Detailed DescriptionA disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future.Recommended
VLT0230...
Arguments•arg1 = PD NameDetailed DescriptionPortions of the physical disk that were formerly inaccessible have been recovered. This alert is provided
PDR27Message Dedicated hot spare assigned toarg1.Arguments•arg1 = PD NameDetailed DescriptionA user assigned a physical disk as a dedicated hot spare
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Severity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
Category StorageSubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Defaul
Recommended Response ActionNo response action is required.Category StorageSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/Event
Detailed DescriptionThe only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are
Arguments•arg1 = physical diskDetailed DescriptionA user has initiated a clear operation on a physical disk.Recommended Response ActionNo response act
PDR40Message The blink operation has ceased onarg1.Arguments•arg1 = physical diskDetailed DescriptionThis alert is provided for informational purposes
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR42Messagearg1
1IntroductionThe Event Message Reference contains the error and event information generated by firmware and other agents that monitor system component
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
Trap/EventID 4345LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Category StorageSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID 4347LCD Message No LCD message display defined.Initial
Recommended Response ActionAssign a larger disk as the global hot spare.Category StorageSubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Tr
Recommended Response ActionMake sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the
Detailed DescriptionThis message is generated after a disk media error is corrected on a physical disk.Recommended Response ActionNo response action i
Detailed DescriptionThe bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the ta
PDR58Messagearg1is incompatible.Arguments•arg1 = PD NameDetailed DescriptionA user attempted to replace a disk with another disk that is using an inco
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR60Message Err
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Severity 3 InformationIndicates a medium-to-low impact problem that involves a partial or noncritical loss of functionality; operations are impaired b
Severity Severity 1 (Critical)Trap/EventID 4345LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vi
SubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID 4347LCD Message No LCD message display defined.Initial Default. SNMP Al
Severity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
SubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#L
Recommended Response ActionNo response action is required.Category StorageSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/Event
Detailed DescriptionThe physical disk participating in the copyback operation failed.Recommended Response ActionReplace the disk and retry the operati
Detailed DescriptionThis alert is provided for informational purposesRecommended Response ActionNo response action is required.Category StorageSubCate
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
•arg2 = physical diskDetailed DescriptionA user aborted an ongoing copyback operation. The operation did not complete.Recommended Response ActionRe-is
Arguments•arg1 = physical diskDetailed DescriptionSecurity on a secure encrypted disk was activated.Recommended Response ActionNo response action is r
2AMP Event MessagesAMP0300Message The system boardarg1current is less than the lower warning threshold.Arguments•arg1 = nameDetailed DescriptionNoneRe
PDR84Messagearg1Security key has changed.Arguments•arg1 = physical diskDetailed DescriptionThe Security key on a secure encrypted disk was activated.R
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR86Message Bad
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
Trap/EventID 4347LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
SubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#L
Category StorageSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID 4347LCD Message No LCD message display defined.Initial
Recommended Response ActionVerify that the disk is healthy and that it has not been removed. Check the cables. See the Cables Attached Correctly secti
Detailed DescriptionInternal Use Only.Recommended Response ActionInternal Use Only.Category StorageSubCategory PDR = Physical DiskSeverity Severity 2
Detailed DescriptionThe controller detected a drive removalRecommended Response ActionIf unintended, verify drive installation. Remove and reseat the
Arguments•arg1 = numberDetailed DescriptionThe controller received a SMART error from the drive. The drive is operational but needs replacement.Recomm
Trap/EventID 2177LCD Message System board <name> current is outside of range. Contact SupportInitial Default. LC LogFilter VisibilityIPMI Alert
PDR1103Message Drivearg1is the hot-spare drive.Arguments•arg1 = numberDetailed DescriptionNoneRecommended Response ActionNo response action is require
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPDR1104Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
Category System HealthSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.I
Detailed DescriptionThe controller detected that the drive was removed.Recommended Response ActionVerify drive installation. Remove and reseat the fai
Arguments•arg1 = number•arg2 = bayDetailed DescriptionThe controller received a SMART error from the drive. The drive is operational but needs replace
PDR1019Message Drivearg1in disk drive bayarg2is no longer the hot-spare drive.Arguments•arg1 = number•arg2 = bayDetailed DescriptionNoneRecommended Re
Severity Severity 1 (Critical)Trap/EventID 2177LCD Message System board <name> current is outside of range. Contact SupportInitial Default. LC L
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPDR1020Mess
LCD Message Drive <number> in disk drive bay <bay> is in the critical array. Replace drive.Initial Default. FALSEFilter VisibilityIPMI Ale
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message Drive <number> in disk drive bay <bay> is in the failed array. Replace drive.I
Category System HealthSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.I
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PDR = Physical DiskSeverity Severi
Arguments•arg1 = number•arg2 = bayDetailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory
496
26PST Event MessagesPST0128Message No memory is detected.Detailed DescriptionSystem BIOS was unable to detect memory in the system . This exception oc
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPST0130Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPST0132Mess
BAT1027...
SubCategory AMP = AmperageSeverity Severity 3 (Informational)Trap/EventID 2179LCD Message No LCD message display defined.Initial Default. LC LogFilter
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPST0134Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPST0136Mess
PST0138Message SuperIO failed.Detailed DescriptionSystem BIOS detected a failure with the SIO. This exception occurred early in system power on, thus
Detailed DescriptionSystem BIOS failed to initialize the system management interrupt. This exception occurred early in system power on, thus the syste
Recommended Response ActionCompare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory
Category System HealthSubCategory PST = BIOS POSTSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Shut-down test failed. Power cycle system
Trap/EventID FALSELCD Message Remote access controller configuration failed. Check screen messageInitial Default. FALSEFilter VisibilityIPMI Alert SNM
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE508
27PSU Event MessagesPSU8501Message Unable to retrieve PSUarg1input voltage information.Arguments•arg1 = slot numberDetailed DescriptionUnable to retri
Category System HealthSubCategory AMP = AmperageSeverity Severity 1 (Critical)Trap/EventID 2177LCD Message Disk drive bay <name> current is outs
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Category AuditSubCategory PSU = Power SupplySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial De
Detailed DescriptionUnable to update the PSU firmware due to PMBus communication errors.Recommended Response ActionRetry the firmware update operation
Detailed DescriptionUnable to set redundancy policy because PSU enumeration is in progress. The policy can be set after PSU enumeration is complete.Re
Detailed DescriptionThe operation to read the FRU data from the PSU indentified in the message did not complete successfully due to internal communica
Recommended Response ActionNo response action is required.Category AuditSubCategory PSU = Power SupplySeverity Severity 3 (Informational)Trap/EventID
Detailed DescriptionThe power supply is not providing any power. This may be because the power supply switch is in the off position or the power suppl
Recommended Response ActionReview system power policy, check system logs for power related failures, and review system configuration changes.Category
Detailed DescriptionThe enclosure detected that a power supply unit was removed and is no longer functioning in optimal condition.Recommended Response
Detailed DescriptionThe enclosure detected that a power supply unit has failed.Recommended Response ActionCheck for other messages related to the stat
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PSU = Power SupplySeverity Severit
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PSU = Power SupplySeverity Severit
Arguments•arg1 = numberDetailed DescriptionThe power supply is installed correctly but an input source is not connected or is not functional.Recommend
PSU0004Message The power input for power supplyarg1is outside of range.Arguments•arg1 = numberDetailed DescriptionThe operating requirements for the p
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEPSU0006Message
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FAL
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 3 (Informational)Trap/EventID 2187LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory AMP = AmperageSeverity Severity 3
Category System HealthSubCategory PSU = Power SupplySeverity Severity 1 (Critical)Trap/EventID 2185LCD Message An under voltage fault detected on PSU
Recommended Response Action1) Remove and re-install the power supply. 2) Check cables and subsystem components in the system for damage. 3) If the iss
Detailed DescriptionPower supplies should be of the same input type and power rating.Recommended Response ActionInstall matched power supplies and rev
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PSU = Power SupplySeverity Severit
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PSU = Power SupplySeverity Severit
Detailed DescriptionIn order to meet service requirements the supply must be shut down.Recommended Response ActionRemove input power at the power supp
Detailed DescriptionThe power supply is installed correctly but an input source is not connected or is not functional.Recommended Response ActionVerif
Detailed DescriptionThe system did not respond correctly to a power down request.Recommended Response ActionDisconnect Input PowerCategory System Heal
Detailed DescriptionStatus from the power supply indicates a power supply exception occurred. The power supply will try to operate in a degraded state
Arguments•arg1 = numberDetailed DescriptionStatus from the power supply indicates a power supply exception occurred. The power supply will try to oper
Category System HealthSubCategory AMP = AmperageSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message System level current is outside of range.
PSU0077Message Power supplyarg1vendor type mismatch detected.Arguments•arg1 = numberDetailed DescriptionPower supplies should be of the same input typ
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEPSU0080Message
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FAL
Trap/EventID 2185LCD Message Output under voltage fault detected on PSU <number>.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEm
SubCategory PSU = Power SupplySeverity Severity 1 (Critical)Trap/EventID 2185LCD Message Output over current fault detected on PSU <number>. Che
Recommended Response ActionIf problem persist, remove and re-install power supply.Category System HealthSubCategory PSU = Power SupplySeverity Severit
28PSUA Event MessagesPSUA0016Message Power supplyarg1is absent.Arguments•arg1 = numberDetailed DescriptionThe supply has been removed or has failed.Re
548
29PWR Event MessagesPWR8500Message Chassis power state updated toarg1fromarg2.Arguments•arg1 = new power state•arg2 = old power stateDetailed Descript
Trap/EventID FALSELCD Message System level current is outside of range. Contact SupportInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEma
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNM
SubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFi
SubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFi
Recommended Response ActionNo response action is required. Make sure there are enough PSUs to support redundancy at the specified power budget.Categor
Detailed DescriptionUnable to set the chassis power indentified in the message.Recommended Response ActionRetry the operation. If the issue persists,
Category AuditSubCategory PWR = Power UsageSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default.
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSEPWR8518Messa
PWR8520Message Initiated the chassis reset operation.Detailed DescriptionThe chassis reset operation was initiated.Recommended Response ActionNo respo
Detailed DescriptionThe chassis power cycle operation was initiated.Recommended Response ActionNo response action is required.Category AuditSubCategor
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEAMP0318Mess
Category AuditSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Def
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSEPWR8531Messa
PWR8533Message Power cap changed fromarg1W AC toarg2W AC.Arguments•arg1 = power value•arg2 = power valueDetailed DescriptionPower cap seeting was chan
PWR8535Message Unable to set Server Based Power Management Mode to disable.Detailed DescriptionUnable to set Server Based Power Management Mode to dis
Detailed DescriptionServer Performance Over Power Redundancy is disabled.Recommended Response ActionNo response action is required.Category AuditSubCa
Category AuditSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Def
SubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFi
Recommended Response ActionTurn on the server identified in the message. If the issue persists, contact your service provider.Category AuditSubCategor
AMP0320Message Chassis power level current is greater than the upper warning threshold.Detailed DescriptionProduct documentation contains information
Arguments•arg1 = slot numberDetailed DescriptionIncorrect power inventory information reported by the iDRAC for the server identified in the message.R
Detailed DescriptionThe chassis was already turned off, when the power off request was received.Recommended Response ActionNo response action is requi
Category AuditSubCategory PWR = Power UsageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default.
SubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFi
•arg3 = priority numberDetailed DescriptionThis situation occurs if the iDRAC is found to be turned off after power allocation information is sent by
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEPWR8556Message
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
Severity Severity 1 (Critical)Trap/EventID 8417LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote Sys
Category AuditSubCategory PWR = Power UsageSeverity Severity 1 (Critical)Trap/EventID 8417LCD Message No LCD message display defined.Initial Default.
Detailed DescriptionThe Chassis Management Controller is unable to communicate with the iDRAC service processor for the Server identified in the messa
Detailed DescriptionProduct documentation contains information on correct configuration. The failure could also be caused by a faulty component or rel
PWR8567Message Unable to turn off Serverarg1on a power cycle action.Arguments•arg1 = server numberDetailed DescriptionUnable to turn off the Server on
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
SubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFi
Recommended Response ActionWait for three minutes, and then retry the operation. If the issue persists, remove and reinsert the server and wait for th
Detailed DescriptionThe Virtual Reseat initiated on the Sleeve identified in the message successfully turned off the Sleeve. However, the Sleeve did n
Arguments•arg1 = slot numberDetailed DescriptionThe Chassis Management Controller is unable to turn on the iDRAC because power required is less than a
PWR8580Message Chassis Management Controller is unable to turn on server-arg1because the Chassis is not turned on.Arguments•arg1 = slot numberDetailed
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSEPWR8582Messa
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Of
3ASR Event MessagesASR8500Message Watchdog timer is disabled.Detailed DescriptionWatchdog timer is disabled. The watchdog timer is an internal mechani
Recommended Response ActionNo response action is required.Category AuditSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID F
Detailed DescriptionThe server cannot be turned on if the chassis enclosure is open.Recommended Response ActionThe chassis enclosure is open. Retry th
Arguments•arg1 = slot numberDetailed DescriptionThe PCIe Mezzanine card in the slot B1 is absent. Without PCIe Mezzannine cards, the chassis PCIe card
PWR8591Message Servers are turned off to allocate power to the newly inserted hard disk drives.Detailed DescriptionBefore inserting hard disk drives,
PWR8593Message Chassis Management Controller is unable to turn on or turn off the chassis because the chassis infrastructure component firmware update
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPWR8595Mess
Category AuditSubCategory PWR = Power UsageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default.
Recommended Response ActionRemove PSUCategory AuditSubCategory PWR = Power UsageSeverity Severity 1 (Critical)Trap/EventID 8417LCD Message No LCD mess
Recommended Response ActionIncrease power cap.Category System HealthSubCategory PWR = Power UsageSeverity Severity 2 (Warning)Trap/EventID 2274LCD Mes
SubCategory PWR = Power UsageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. NoneFilter Vis
CMC8505...
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEASR0001Mess
LCD Message System performance degraded. Check PSUs and system configurationInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPWR1004Mess
PWR1006Message The system halted because system power exceeds capacity.Detailed DescriptionThe system may shutdown.Recommended Response ActionReview s
Detailed DescriptionTo avoid shutdown, system performance has been degraded.Recommended Response ActionReview system configuration, upgrade power supp
Category System HealthSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Ini
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPWR0106Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPWR2002Mess
ASR0003Message The watchdog timer power cycled the system.Detailed DescriptionThe operating system or an application failed to communicate to the base
PWR2004Message System booted automatically into diagnostics.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PWR = Power UsageSeverity Severity
Category System HealthSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Ini
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEPWR2205Mess
PWR2208Message The system is in a sleep state.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System Health
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory PWR = Power UsageSeverity Severity
Category System HealthSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Ini
618
30RAC Event MessagesRAC038Message Unable to perform the operation due to an unknown error in iDRAC.Detailed DescriptionThe operation failed to run due
ASR0009Message The system returned from a watchdog timer event.Detailed DescriptionThe system is communicating to the baseboard management controller
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSERAC042Messa
RAC044Message Unable to update some event filter settings.Detailed DescriptionSome event filter settings were not updated due to problems encountered
Detailed DescriptionThe event notficiation selected is not supported for the event filter specified.Recommended Response ActionRefer to the iDRAC User
Category ConfigurationSubCategory RAC = RAC EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initi
31RDU Event MessagesRDU8500Message CMCarg1: activeArguments•arg1 = slot numberDetailed DescriptionThe CMC is identified in the message is active.Recom
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
Category AuditSubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Recommended Response ActionCheck the status of the standby CMC and make sure the firmware version matches the primary CMC. Then reseat the CMC and ret
Arguments•arg1 = slot numberDetailed DescriptionFor failover to occur, the standby CMC needs to be present, at the same version as the primary and hea
ASR0101Message The OS watchdog timer reset the system.Detailed DescriptionThe operating system or an application failed to communicate within the time
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSERDU8512Messa
SubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFil
Category AuditSubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Recommended Response ActionNo response action is required. Wait until the firmware update is complete and retry the operation.Category AuditSubCategor
Detailed DescriptionThe communication between the primary and standby CMCs was lost. This may occur when the CMC identified in the message is restarti
Arguments•arg1 = slot numberDetailed DescriptionThe active CMC has been removed from the chassis. If standby CMC is present, it will become active.Rec
RDU8523Message CMCarg1: reset by peer CMCArguments•arg1 = slot numberDetailed DescriptionThe CMCidentified in the message was reset by other CMC. This
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSERDU0001Messa
RDU0003Message Fan redundancy is degraded.Detailed DescriptionOne of more fans have failed or have been removed or a configuration change occurred whi
Detailed DescriptionOne of more fans have failed or have been removed or a configuration change occurred which requires additional fans.Recommended Re
Detailed DescriptionThe operating system or an application failed to communicate within the timeout period. The system was powered down. (IPMI sensor
Recommended Response ActionCheck the event log for power supply failures. Review system configuration and power consumption.Category System HealthSubC
SubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID 2475LCD Message No LCD message display defined.Initial Default. LC LogFilt
Trap/EventID 2474LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
SubCategory RDU = RedundancySeverity Severity 2 (Warning)Trap/EventID 2474LCD Message No LCD message display defined.Initial Default. LC LogFilter Vis
644
32RED Event MessagesRED001Message Job completed successfully.Detailed DescriptionJob completed successfully.Recommended Response ActionNo response act
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSERED006Message
RED008Message Package extraction failed.Detailed DescriptionPackage extraction failed.Recommended Response ActionValidate that the update package is n
648
33RFL Event MessagesRFL2000Message Internal Dual SD Modulearg1is present.Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionNo re
Category System HealthSubCategory ASR = Auto Sys ResetSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initi
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message Internal Dual SD Module <name> failed. Check SD CardInitial Default. FALSEFilter Vis
SubCategory RFL = IDSDM MediaSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message Internal Dual SD Module <name> is write protected. Check
Category System HealthSubCategory RFL = IDSDM MediaSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Ini
654
34RFLA Event MessagesRFLA2001Message Internal Dual SD Modulearg1is absent.Arguments•arg1 = nameDetailed DescriptionThe SD card module is not detected
35RFM Event MessagesRFM1018Message Removable Flash Media is absent.Detailed DescriptionNoneRecommended Response ActionNo response action is required.C
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSERFM1020Mess
RFM1022Message Removable Flash Media is ready.Detailed DescriptionNoneRecommended Response ActionIf unintended, reinstall the flash media.Category Sys
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Detailed DescriptionAt boot, the Card Identification (CID) signature of the card is different from the Non-volatile (NV) storage value or the card is
Category System HealthSubCategory RFM = FlexAddress SDSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initi
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSERFM1031Mess
RFM1033Message Removable Flash Media is writable.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System Hea
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory RFM = FlexAddress SDSeverity Sever
666
36RRDU Event MessagesRRDU0001Message Internal Dual SD Module is redundant.Detailed DescriptionNoneRecommended Response ActionNo response action is req
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSERRDU0003Mes
RRDU0005Message Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations.Detailed DescriptionThe current operati
4BAT Event MessagesBAT1000Message Battery onarg1is missing.Arguments•arg1 = controller nameDetailed DescriptionThe controller cannot communicate with
670
37SEC Event MessagesSEC0001Message The drive bay is open.Detailed DescriptionThe drive bay is open. A drive may be added or removed. System performanc
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESEC0003Mess
SEC0005Message Unauthorized docking is detected.Detailed DescriptionA removable component may have been tampered with, or installed incorrectly, or do
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory SEC = Security EventSeverity Sever
Category System HealthSubCategory SEC = Security EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESEC0031Mess
SEC0033Message The chassis is open while the power is off.Detailed DescriptionThe chassis is open while the power is off. System security may have bee
Detailed DescriptionThe chassis is open. System performance may be degraded, and security may be compromised.Recommended Response ActionClose the chas
Severity Severity 3 (Informational)Trap/EventID 4275LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilt
Category System HealthSubCategory SEC = Security EventSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message BIOS detected an error configuring T
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message BIOS detected a TXT error during POST. Check system configuration.Initial Default. FALSEFi
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESEC0603Mess
SEC0605Message A setup password violation was corrected.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category Sys
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory SEC = Security EventSeverity Sever
Category System HealthSubCategory SEC = Security EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
688
38SEL Event MessagesSEL0002Message Logging is disabled.Detailed DescriptionThis message appears when event logging of a specific type is disabled by t
SubCategory BAT = Battery EventSeverity Severity 2 (Warning)Trap/EventID 4274LCD Message No LCD message display defined.Initial Default. SNMP Alert;#L
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSESEL0004Message
SEL0007Message All event logging is enabled.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSu
SEL0010Message System event log (SEL) is almost full.Detailed DescriptionWhen the event log is full, additional events are not written to the log or o
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory SEL = Sys Event LogSeverity Severi
Category System HealthSubCategory SEL = Sys Event LogSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.I
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESEL1208Mess
SEL1210Message The time-stamp clock is synchronized.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System
Detailed DescriptionSystem setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1
Category System HealthSubCategory SEL = Sys Event LogSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initia
CMC8555...
Category StorageSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/EventID 4275LCD Message No LCD message display defined.Initial
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESEL1307Mess
SEL1309Message User selected a boot source.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSub
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory SEL = Sys Event LogSeverity Severi
Category System HealthSubCategory SEL = Sys Event LogSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.I
Category System HealthSubCategory SEL = Sys Event LogSeverity Severity 2 (Warning)Trap/EventID 2378LCD Message No LCD message display defined.Initial
Recommended Response Action1)Check that the Name or IP address, User Name, and Password of the member are correct. 2)Check that the member is not a le
Detailed DescriptionGroup master CMC could not log into the group member CMC.Recommended Response ActionCheck login credentials of CMCCategory System
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory SEL = Sys Event LogSeverity Severi
Recommended Response ActionChassis management controller (CMC) redundancy is degraded.Category System HealthSubCategory SEL = Sys Event LogSeverity Se
Recommended Response ActionNo response action is required.Category StorageSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/Event
SubCategory SEL = Sys Event LogSeverity Severity 1 (Critical)Trap/EventID 2377LCD Message No LCD message display defined.Initial Default. LC LogFilter
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
712
39STOR Event MessagesSTOR1Message A devicearg1is in an unknown state.Arguments•arg1 = device nameDetailed DescriptionThe controller cannot communicate
Severity Severity 3 (Informational)Trap/EventID 4179LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilt
Severity Severity 1 (Critical)Trap/EventID 4177LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vi
Detailed DescriptionA comparison of storage inventory collected before and after the host re-boot/re-set. reports differences. There could have been s
Detailed DescriptionHigh Availability RAID is not supported by this firmware release. This event may occur during the upgrade process.Recommended Resp
Recommended Response ActionUpdate the Chassis Infrastructure firmware.Category StorageSubCategory STOR = StorageSeverity Severity 1 (Critical)Trap/Eve
Category ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Arguments•arg1 = controller nameDetailed DescriptionA controllers battery was replaced.Recommended Response ActionNo response action is required.Categ
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESTOR010Mess
STOR012Message Provided Physical disk not valid for this operationDetailed DescriptionOne or more of provided physical disks cannot be used.Recommende
Detailed DescriptionHit maximum limit for virtual disks on the controllerRecommended Response ActionA new virtual disk cannot be created until one is
Category ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESTOR022Mess
STOR024Message Configuration already committed, cannot commit until previous commit succeeds or is cancelledDetailed DescriptionConfiguration changes
STOR026Message Configuration Job not Created, there are no pending Configuration changesDetailed DescriptionThere are no pending configuration changes
Detailed DescriptionCould not find the provided virtual diskRecommended Response ActionProvide a valid virtual disk FQDD.Category ConfigurationSubCate
BAT1003Message The battery onarg1learn cycle has completed.Arguments•arg1 = Controller nameDetailed DescriptionThis alert is provided for informationa
Category ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Recommended Response ActionWait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Contro
Category ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Recommended Response ActionProvide a valid parameter value for specifed parameterCategory ConfigurationSubCategory STOR = StorageSeverity Severity 2 (
Recommended Response ActionProvide valid attributeCategory ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD M
Detailed DescriptionThe attribute value is not supported in the current configurationRecommended Response ActionProvide a settable value for the speci
Category ConfigurationSubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defa
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESTOR051Mess
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEBAT1005Message T
STOR053Message Controller key not present, controller needs key from Dell Key Management ServerDetailed DescriptionSystem could not obtain key from th
Detailed DescriptionThe BIOS is not Dell Key Management capableRecommended Response ActionInformational Message. Refer to the controller users guide f
Recommended Response ActionEnable CSIOR and then run CSIOR. Invoke the GetRSStatus wsman method(Refer LCManagement profile document for more details o
SubCategory STOR = StorageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter Visib
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Of
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE745
746
40SUP Event MessagesSUP001Message Insufficient parameters provided.Detailed DescriptionInsufficient Parameters provided for the WSMAN command.Recommen
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESUP005Messa
SUP015Message Input parameters values should not be NULL.Detailed DescriptionOne of the parameters specified received a NULL value that prevented the
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
Detailed DescriptionThe specified start time is invalid.Recommended Response ActionStart Time should be in the form YYYYMMDDHHMMSS. Or it should be TI
Category UpdatesSubCategory SUP = FW Update JobSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
41SWC Event MessagesSWC8533Message Unable to complete delete all keys operation for service accounts for all slots due to problem saving key file.Deta
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWC8535Messa
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
SubCategory SWC = Software ConfigSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFil
Recommended Response ActionNo response action is required.Category AuditSubCategory SWC = Software ConfigSeverity Severity 3 (Informational)Trap/Event
Trap/EventID 4274LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Detailed DescriptionThe description for the Profile identified in the message was edited.Recommended Response ActionNo response action is required.Cat
Detailed DescriptionA new Profile identified in the message has been created.Recommended Response ActionNo response action is required.Category AuditS
Arguments•arg1 = profile name•arg2 = slot numberDetailed DescriptionUnable to communicated with iDRAC.Recommended Response ActionCheck if iDRAC is rea
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWC8511Messa
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Category AuditSubCategory SWC = Software ConfigSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defau
Detailed DescriptionUnable to modify the password of the User identified in the message.Recommended Response ActionMake sure: 1) The login credentials
Arguments•arg1 = original user name•arg2 = new_user name•arg3 = error code•arg4 = error messageDetailed DescriptionUnable to modify the user name spec
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWC8522Messa
Severity Severity 2 (Warning)Trap/EventID 4274LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
SubCategory SWC = Software ConfigSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC L
Recommended Response ActionMake sure the user name is valid. If communication with iDRAC is not successful, reset the iDRAC. Retry the operation after
Recommended Response ActionIf communications with the iDRAC is not functioning, reset the iDRAC and retry the operation after a few minutes. Run the R
Detailed DescriptionThe Chassis Management Controller is unable to set the administrator role for the iDRAC root user. This can happen if the communct
SWC8600Message Selected profile was not applied toarg1Arguments•arg1 = server listDetailed DescriptionThe profile version must be compatible with the
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESWC8602Mess
Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE F
LCD Message No LCD message display defined.Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleReset
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. NoneFilter VisibilityIPMI Alert SNMP
SubCategory BAT = Battery EventSeverity Severity 2 (Warning)Trap/EventID 4274LCD Message No LCD message display defined.Initial Default. SNMP Alert;#L
Detailed DescriptionThe server Lifcycle Controller responded with a failure for a WSMAN request.Recommended Response ActionVerify correct operation of
SWC8611Message Profile "arg1" and Server (Service Tag:arg2in Slotarg3are not compatible.Arguments•arg1 = profile_name•arg2 = service tag•arg
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESWC8613Mess
Initial Default. NoneFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE F
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Severity Severity 3 (Informational)Trap/EventID 2339LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FAL
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
788
42SWU Event MessagesSWU8500Message The schedule toarg1Lifecycle Controller on serverarg2was not successful.Arguments•arg1 = update/reinstall/rollback•
Category StorageSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/EventID 4275LCD Message No LCD message display defined.Initial
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Category UpdatesSubCategory SWU = Software ChangeSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initi
Recommended Response ActionNo response action required.Category UpdatesSubCategory SWU = Software ChangeSeverity Severity 3 (Informational)Trap/EventI
Detailed DescriptionThe firmware update operation of IOM infrastructure is successful.Recommended Response ActionNo response action is required.Catego
Arguments•arg1 = error noDetailed DescriptionThe IOM firmware update operation was not successful. Unable to initiate the Update process.Recommended R
SWU8517Message Unable to update the iDRAC firmware on the server in slotarg1. The Image file is not accessible. ErrorCode=0xarg2.Arguments•arg1 = slot
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWU8519Messa
Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
SubCategory SWU = Software ChangeSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilt
CPU0806...
Recommended Response ActionNo response action is required.Category StorageSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/Event
Recommended Response ActionNo response action is required.Category UpdatesSubCategory SWU = Software ChangeSeverity Severity 3 (Informational)Trap/Eve
SubCategory SWU = Software ChangeSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilt
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Category UpdatesSubCategory SWU = Software ChangeSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Def
Detailed DescriptionThe PSU firmware update operation was not successful, because the firmware Image file could not be transferred.Recommended Respons
Recommended Response ActionMake sure that the CMC firmware image file is available at the location specified in the oepration, and then retry the oper
SubCategory SWU = Software ChangeSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilt
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWU8550Messa
SWU8552Message Unable to update the firmware of Active CMC.Detailed DescriptionThe firmware update process of Active CMC was not successful.Recommende
Detailed DescriptionLocal CMC firmware update process is initiated.Recommended Response ActionNo response action is required.Category UpdatesSubCatego
Detailed DescriptionA chassis-wide switch configuration image is applied to the first node of a multi-node sled upon insertion or chassis initializati
43SYS Event MessagesSYS001Message The operation was successful.Detailed DescriptionThe operation requested successfully completed.Recommended Response
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSESYS006Messa
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
44TMP Event MessagesTMP8500Message I/O Modulearg1temperature exceeded operating range.Arguments•arg1 = iom slot nameDetailed DescriptionThe temperatur
Detailed DescriptionThe controller battery cannot maintain sufficient charge level to function properly or the battery is discharging.Recommended Resp
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP Aler
Category StorageSubCategory TMP = TemperatureSeverity Severity 2 (Warning)Trap/EventID 4210LCD Message No LCD message display defined.Initial Default.
Recommended Response ActionCheck for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check
Arguments•arg1 = Enclosure nameDetailed DescriptionYou have changed the value for the maximum temperature probe warning threshold. This alert is provi
TMP7Messagearg1has failed.Arguments•arg1 = Temp Sensor NameDetailed DescriptionA device has been failed and the system is no longer functioning in opt
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSETMP0201Mess
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
LCD Message CPU <number> temperature is outside of range. Check fansInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Lo
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP Alert
Detailed DescriptionThe battery or the battery charger is not functioning properly. The battery may have an inadequate charge.Recommended Response Act
SubCategory TMP = TemperatureSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message System board <name> temperature is outside of range Che
Category System HealthSubCategory TMP = TemperatureSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial D
Recommended Response ActionCheck system operating environment and review event log for fan failures.Category System HealthSubCategory TMP = Temperatur
Detailed DescriptionAmbient air temperature is too warm or cool.Recommended Response ActionCheck system operating environment and review event log for
Detailed DescriptionAmbient air temperature is too cool.Recommended Response ActionCheck system operating environment.Category System HealthSubCategor
Detailed DescriptionAmbient air temperature is too warm or one or more fans may have failed.Recommended Response ActionCheck system operating environm
Detailed DescriptionAmbient air temperature is too warm or cool.Recommended Response ActionCheck system operating environment and review event log for
Detailed DescriptionAmbient air temperature is too cool.Recommended Response ActionCheck system operating environment.Category System HealthSubCategor
Category System HealthSubCategory TMP = TemperatureSeverity Severity 2 (Warning)Trap/EventID 2162LCD Message No LCD message display defined.Initial De
Trap/EventID 2161LCD Message Inlet temperature is outside of range . Check environmentInitial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEma
BAT1026Message Thearg1has recovered cached data from the Battery Backup Unit (BBU).Arguments•arg1 = controller nameDetailed DescriptionThe controller
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSETMP0125Mess
TMP0127Message Disk drive bay temperature is greater than the upper critical threshold.Detailed DescriptionAmbient air temperature is too warm or one
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory TMP = TemperatureSeverity Severity
Category System HealthSubCategory TMP = TemperatureSeverity Severity 1 (Critical)Trap/EventID 2161LCD Message No LCD message display defined.Initial D
Trap/EventID 2161LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSETMP0136Message
846
45USR Event MessagesUSR8500Message Excessive login failures fromarg1; blocked forarg2seconds.Arguments•arg1 = IP address•arg2 = numberDetailed Descrip
SubCategory USR = User TrackingSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC Log
Recommended Response ActionContact the administrator and ensure the username and password credentials used in the operation are correct.Category Audit
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEBAT1034Message T
Recommended Response ActionNo response action is required.Category AuditSubCategory USR = User TrackingSeverity Severity 3 (Informational)Trap/EventID
•arg4 = error nunberDetailed DescriptionThe login attempt with details specified in the message was not successful.Recommended Response ActionContact
USR8509Message Login was not successful (username=arg1, ip=arg2, error=0xarg3, type=arg4)Arguments•arg1 = username•arg2 = ip address•arg3 = error no•a
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power
Detailed DescriptionSuccessful login by Username identified in the message.Recommended Response ActionContact the administrator and ensure the usernam
USR107Messagearg1operation was performed byarg2onarg3ofarg4.Arguments•arg1 = Set/Invoke•arg2 = username•arg3 = methodname name or instance•arg4 = clas
856
46VDR Event MessagesVDR97Message Patrol Read corrected a media error onarg1.Arguments•arg1 = VD NameDetailed DescriptionThe Patrol Read task has encou
Severity Severity 1 (Critical)Trap/EventID 4353LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vi
SubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventID 4355LCD Message No LCD message display defined.Initial Default. SNMP Ale
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEBAT0001Message
Recommended Response ActionNo response action is required.Category StorageSubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventI
Detailed DescriptionOne or more physical disks included in the virtual disk have failed. If the virtual disk is non-redundant (does not use mirrored o
VDR9Messagearg1consistency check has started.Arguments•arg1 = virtual diskDetailed DescriptionA consistency check operation on a virtual disk has star
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEVDR11Messagearg1
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log
Severity Severity 1 (Critical)Trap/EventID 4353LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vi
Category StorageSubCategory VDR = Virtual DiskSeverity Severity 1 (Critical)Trap/EventID 4353LCD Message No LCD message display defined.Initial Defaul
Recommended Response ActionReplace the failed or corrupt disk. You can identify a disk that has failed by locating the disk that has a red "X&quo
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
BAT0003Message The system board battery is present.Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System H
Detailed DescriptionThe re-configuration operation on the virtual disk completed.Recommended Response ActionNo response action is required.Category St
Detailed DescriptionYou paused the Check Consistency operation on a virtual disk.Recommended Response ActionTo resume the Check Consistency operation,
Detailed DescriptionA user has caused a mirrored virtual disk to be split. When a virtual disk is mirrored, its data is copied to another virtual disk
Arguments•arg1 = virtual diskDetailed DescriptionA user changed the write policy for a virtual disk.Recommended Response ActionThis alert is provided
VDR32Message Background initialization has started forarg1.Arguments•arg1 = virtual diskDetailed DescriptionBackground initialization of a virtual dis
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEVDR34Message Bac
Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TR
Trap/EventID 4355LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
SubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventID 4355LCD Message No LCD message display defined.Initial Default. SNMP Ale
Category StorageSubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventID 4355LCD Message No LCD message display defined.Initial D
Detailed DescriptionThe system has to remain powered on to charge the battery.Recommended Response ActionAllow the PERC RAID controller battery to cha
Recommended Response ActionNo response action is required.Category StorageSubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventI
Detailed DescriptionThis alert is provided for informational purposes.Recommended Response ActionNo response action is required.Category StorageSubCat
Detailed DescriptionA disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk b
Arguments•arg1 = VD NameDetailed DescriptionA redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the failure of
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEVDR51Message The
Trap/EventID 4354LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter VisibilityIPMI Alert SNMP AlertE
Severity Severity 2 (Warning)Trap/EventID 4354LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilter Vis
Recommended Response ActionReplace the missing or failed physical disk.Category StorageSubCategory VDR = Virtual DiskSeverity Severity 3 (Informationa
Detailed DescriptionThis message occurs if there are medium errors in the physical drives.Recommended Response ActionReplace the failed drives.Categor
Detailed DescriptionThis alert message occurs if there are medium errors in the physical drives.Recommended Response ActionNo response action is requi
Category System HealthSubCategory BAT = Battery EventSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Storage battery has failed. Check bat
•arg2 = VD NameDetailed DescriptionThis alert message occurs if the virtual disk has bad blocks.Recommended Response ActionReplace the disk in the Vir
Arguments•arg1 = args•arg2 = VD NameDetailed DescriptionVirtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member
892
47VFL Event MessagesVFL1001Message Removable Flash Mediaarg1is present.Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionNo resp
Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power O
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
SubCategory VFL = vFlash EventSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter V
Category System HealthSubCategory VFL = vFlash EventSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Removable Flash Media <name> fai
Recommended Response ActionNo response action is required.Category System HealthSubCategory VFL = vFlash EventSeverity Severity 3 (Informational)Trap/
Detailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory VFL = vFlash EventSeverity Severit
CTL29...
Trap/EventID FALSELCD Message Storage battery is absent. Check battery.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log L
Detailed DescriptionThe card is write-protected by the physical latch on the SD card. IDSDM cannot use a write-protected card.Recommended Response Act
Detailed DescriptionThe SD card is not detected or not installed.Recommended Response ActionIf unintended, reinstall the flash media.Category System H
48VFLA Event MessagesVFLA1000Message Removable Flash Mediaarg1is absent.Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionNo res
904
49VLT Event MessagesVLT0300Message CPUarg1arg2voltage is less than the lower warning threshold.Arguments•arg1 = number•arg2 = nameDetailed Description
Category System HealthSubCategory VLT = VoltageSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message CPU <number> <name> voltage is
Detailed DescriptionHigh voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may resul
VLT0305Message CPUarg1arg2voltage is within range.Arguments•arg1 = number•arg2 = nameDetailed DescriptionNoneRecommended Response ActionNo response ac
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSEVLT0201Message
SubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEF
LCD Message No LCD message display defined.Initial Default. LC LogFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRes
Severity Severity 1 (Critical)Trap/EventID 2169LCD Message System board <name> voltage is outside of range. Contact supportInitial Default. LC L
Category System HealthSubCategory VLT = VoltageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defau
Detailed DescriptionSystem hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system
VLT0210Message The memory modulearg1arg2voltage is outside of range.Arguments•arg1 = number•arg2 = nameDetailed DescriptionSystem hardware detected an
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEVLT0212Mess
LCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleRese
Severity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP Aler
Category System HealthSubCategory VLT = VoltageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial
Recommended Response Action1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system
Category System HealthSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.I
Detailed DescriptionSystem hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system
Arguments•arg1 = nameDetailed DescriptionNoneRecommended Response ActionNo response action is required.Category System HealthSubCategory VLT = Voltage
VLT0101Message Processor modulearg1voltage is less than the lower critical threshold.Arguments•arg1 = nameDetailed DescriptionSystem hardware detected
Filter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSEVLT0103Mess
LCD Message Processor module <name> voltage is outside of range. Contact supportInitial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmai
Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP Alert
Category System HealthSubCategory VLT = VoltageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Defau
Recommended Response Action1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technic
Detailed DescriptionSystem hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system
VLT0232Message The mezzanine cardarg1arg2voltage is greater than the upper warning threshold.Arguments•arg1 = number•arg2 = nameDetailed DescriptionSy
Recommended Response ActionCheck the battery at the next service window.Category System HealthSubCategory BAT = Battery EventSeverity Severity 2 (Warn
Initial Default. FALSEFilter VisibilityIPMI Alert SNMP AlertEmail AlertLC Log LCD Power Off Power CycleResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE
Severity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilter VisibilityIPMI Alert SNMP
Detailed DescriptionSystem settings may be preserved if input power is not removed from the power supplies.Recommended Response ActionCheck the batter
Detailed DescriptionSystem settings may be preserved if input power is not removed from the power supplies.Recommended Response ActionCheck the batter
96
5BOOT Event MessagesBOOT8500Message Unable to change the BIOS boot order for the Serverarg1Arguments•arg1 = slot numberDetailed DescriptionUnable to c
98
6CBL Event MessagesCBL8500Message SAS cablearg1to expanderarg2is not connected.Arguments•arg1 = cable id•arg2 = expander idDetailed DescriptionSAS cab