Dell OpenManage Server Administrator Version 7.4 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery Dell OpenManage Server Administrator Version 7.4. Dell OpenManage Server Administrator Version 7.4 Command Line Interface Guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 198
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1

Dell OpenManage Server AdministratorVersion 7.4 Command Line Interface Guide

Strany 3 - Contents

oromconfig mainsystem temps index=0 warnthresh=defaultYou cannot default one value and set another. In other words, if you set the minimum warning thr

Strany 4

oromconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250When you issue the command and the system sets the values you specify, the

Strany 5

Omconfig Preferences MessagesUse the omconfig preferences messages command to select the format of alert messages. The default format is traditional,

Strany 6

name=value pair 1 name=value pair 2 Description128bitorhigher: Sets the encryption levels to 128-bit or higher.attribute=seturl host=<string> po

Strany 7

For example, if a fan probe on the system reads a fan RPM of 300 and your minimum warning threshold value for that fan probe is 600 RPM, then the syst

Strany 8

Table 40. Valid Parameters Of Events for Alert ActionsEvent Name Descriptionevent=batterywarn Sets actions when a battery probe detects a warning valu

Strany 9

Event Name Descriptionevent=storagesyswarn Sets actions when a storage system detects a warning value.event=storagesysfail Sets actions when a storage

Strany 10

Example Chassis Intrusion ActionsTo clear all alert actions for chassis intrusion, type:omconfig system alertaction event=intrusion clearall=trueoromc

Strany 11 - Introduction

name=Value Pair Descriptionfalse: Disables an individual platform event filter.index=number Sets the index for the destination.ipaddress=<ipv4 addr

Strany 12

Components And Events Of Platform EventsThe following table lists the components and the events for which you can set platform events. Components are

Strany 13 - Primary CLI Commands

1IntroductionDell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution through either an integrated

Strany 14 - Failure Messages

Event Name Descriptionevent=redunlost Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperativ

Strany 15 - Command Syntax Overview

• IndexSourceAt present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event notification for

Strany 16

Table 45. System Event Severity ParametersCommand Result Descriptionomconfig system events type=<component name> severity=info or omconfig serve

Strany 17 - Using The omhelp Command

Table 46. Valid Parameters Of Web Server Configurationname=value pair Descriptionaction=start Starts the Web server.action=stop Stops the Web server.a

Strany 18 - Table 2. Optional Parameters

system before powering the system down. If you do not want to shut down the operating system first, use the osfirst=false parameter. The following tab

Strany 19 - The Instrumentation Service

name=value pair Descriptiona chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature failure threshold value.Example Ther

Strany 21

5Omconfig System Or Servermodule Assetinfo: Editing Cost Of Ownership ValuesThe omconfig system assetinfo or omconfig servermodule assetinfo command h

Strany 22

Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionthat acquired the system.expensed=yes | no Whether the sy

Strany 23

The following message is displayed:Asset information set successfully.You can type more than one omconfig system assetinfo or omconfig servermodule as

Strany 24

– VMware vSphere 5.5• Added support for the following browsers:– Mozilla Firefox 22 and 23– Internet Explorer 11– Safari 6.0– Google Chrome 27, 28, an

Strany 25

Example Command For Adding Depreciation InformationTo provide a value for a depreciation parameter, type a command of the form: omconfig system asseti

Strany 26

Example Command For Adding Extended Warranty InformationTo provide a value for an extended warranty parameter, type a command of the form: omconfig sy

Strany 27

Example Command For Adding Lease InformationTo provide a value for a lease parameter, type a command of the form: omconfig system assetinfo info=lease

Strany 28

The following message is displayed:Asset information set successfully.You can type more than one omconfig system assetinfo or omconfig servermodule as

Strany 29

For an example, see Example Command For Adding Acquisition Information.Adding Owner InformationThe owner is the party that holds legal property title

Strany 30

Table 58. Valid Parameters Of omconfig system assetinfo info=service Or omconfig servermodule assetinfo info=serviceCommand Level 1Command Level 2Comm

Strany 31 - Hwperformance

Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionmail address, or website address.outsourced=true | false

Strany 32 - Omreport Chassis Intrusion

Table 60. Valid Parameters Of omconfig system assetinfo info=system Or omconfig servermodule assetinfo info=systemCommand Level 1Command Level 2Comman

Strany 33

Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionenddate=<enddate> Date the warranty agreement ends.

Strany 34

6Using The Storage Management ServiceThe CLI of Storage Management enables you to perform reporting, configuration, and management functions of Storag

Strany 35

– M820VRTX • Deprecated support for the following operating systems:– SUSE Linux Enterprise Server 10 SP4– SUSE Linux Enterprise Server 11 SP2– Red Ha

Strany 36

In this example, the id in controller=idis the controller number such that controller 1 is specified as controller=1.Syntax Of Command ElementsThe omr

Strany 37

Syntax DescriptionFor example, the name=<string>parameter is specified as name=VirtualDisk1.[ ]The bracket symbols ([ ]) indicate optional eleme

Strany 39 - Pwrmanagement

7Omreport Storage CommandsThe omreport command allows you to view storage component information for disks, controllers, enclosures, batteries, global

Strany 40

Command Level 1Command Level 2Command Level 3Usefluidcachepool Displays fluid cache pool properties.partition Displays the partition details of the sp

Strany 41

Table 66. omreport Virtual Disk CommandsRequired Command Levels (1, 2, 3)Optional name=value pairs Useomreport storage vdisk Displays property informa

Strany 42

Required Command Levels (1, 2, 3)Optional name=value pairs Useis the controller number and <ENCLOSUREID>is the enclosure ID. Example for SCSI co

Strany 43 - Removableflashmedia

Table 70. Omreport Fan StatusRequired Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useomreport storage enclosure Displays pro

Strany 44

Required Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useinfo=pwrsupplies index=n where id is the controller number and ENCLO

Strany 45 - Servermodule Commands

Table 73. Omreport Enclosure Slot Occupancy Report CommandsRequired Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useomreport

Strany 46 - Commands For Viewing Logs

NOTE: For an overall summary of the CLI commands, type omhelp.NOTE: The omupdate commands are no longer supported in Server Administrator and are repl

Strany 47

Required Command Levels (1, 2, 3)Optional name=value pairs UseOpenManage Server Administrator Storage Management User’s Guide at dell.com/support/manu

Strany 48

Table 78. omreport PCIe SSD CommandRequired Command Levels (1, 2, 3) And name=value pairOptional name=value pairs Useomreport storage pciessdDisplays

Strany 49

Table 82. omreport Fluid Cache Disk CommandRequired Command Levels (1, 2, 3) And name=value pairUseomreport storage fluidcachediskDisplays the propert

Strany 50 - Operatingsystem

8Omconfig Storage CommandsThe omconfig commands allows you to configure physical disks, virtual disks, controllers, enclosures, batteries, global info

Strany 51

Omconfig Physical Disk CommandsThe following sections provide the omconfig command syntax required to execute physical disk tasksTable 85. Omconfig Ph

Strany 52

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to dis

Strany 53

Example to Prepares physical disk 3 on connector 0 of controller 1 for removal. On a SAS controller, the physical disk resides in enclosure 2.Example

Strany 54

Example for SCSI, SATA, and ATA controllersomconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:3Example for SAS controllers omconfig

Strany 55

Omconfig Online Physical DiskDescriptionBrings an offline physical disk back online.Syntaxomconfig storage pdisk action=online controller=id pdisk=<

Strany 56

information about Rebuild Physical Disk, see the Dell OpenManage Online Help .Syntaxomconfig storage pdisk action=rebuild controller=id pdisk=<PDIS

Strany 57

Commandomconfig chassis volts index=3 minwarnthresh=3.3000MessageError! Number with up to 3 digits after decimal point expected, read 3.3000The value

Strany 58 - Omreport Preferences Commands

Omconfig Cancel Replace MemberDescriptionCancels a replace member operation.Syntaxomconfig storage pdisk action=cancelreplacemember controller=id pdis

Strany 59

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to dis

Strany 60

Example for SAS controllers omconfig storage pdisk action=disabledevicewritecache controller=1 pdisk=0:2:3Omconfig Export Reliability LogDescriptionEx

Strany 61

Omconfig Convert Non-RAID To RAIDDescriptionConverts non-RAID to RAID on a physical disk.Syntaxomconfig storage pdisk action=convertnonraidtoraid cont

Strany 62

Required Command Levels (1, 2, 3)Optional name=value pairsaction=fastinit controller=id vdisk=id [force=yes]action=slowinit controller=id vdisk=id [fo

Strany 63

Omconfig Cancel Check ConsistencyDescriptionCancels a check consistency while in progress.Syntaxomconfig storage vdisk action=cancelcheckconsistency c

Strany 64

Omconfig Blink Virtual DiskDescriptionBlinks the physical disks included in a virtual disk.Syntax omconfig storage vdisk action=blink controller=id vd

Strany 65 - Omconfig About

CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated alway

Strany 66

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis

Strany 67

CAUTION: Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. You may receive a warning m

Strany 68

The next level of complexity includes commands that contain command levels 1 and 2. All of the about commands are examples of command level 2 complexi

Strany 69

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis

Strany 70

Omconfig Change Virtual Disk PolicyDescription Changes a virtual disk’s read, write, or cache policy.Syntaxomconfig storage vdisk action=changepolicy

Strany 71

NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis

Strany 72

omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.Example to Reactivate fluid cache on virtual

Strany 73

Required Command Levels (1, 2, 3)Optional name=value pairsNOTE: If you set escrow=yes, specify the escrow file path.action=changesecuritykey controlle

Strany 74

Omconfig Rescan ControllerDescription Rescans a controller. For more information, see the Dell OpenManage Online Help .Syntax omconfig storage control

Strany 75

omconfig Test Controller AlarmTable 90. omconfig Test Controller AlarmDescription Tests the functionality of the controller alarm. The alarm sounds fo

Strany 76

where connector:enclosureID:targetID is the connector number, enclosure number, and slot number.• For SAS controllers:pdisk=connector:targetIDwhere co

Strany 77

Table 91. Parameters And TypesParameters Typecontroller=id Requiredraid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> Requiredsize=<number

Strany 78

Table 93. Size Parametersize=<number | max | min> Parameter SpecificationDescriptionsize=<n> Use this specification to indicate a specific

Strany 79

2Using The omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the detailed help-text interface of Command Line Interfac

Strany 80

Table 95. Disk Cache Policy ParametersDisk Cache Policy diskcachepolicy=disabled | enabled Parameter SpecificationDisabled diskcachepolicy=disabledEna

Strany 81

Table 98. Raid Level And ConcatenationRAID Level or Concatenation raid=n Parameter SpecificationRAID-0 raid=r0RAID-1 raid=r1RAID-5 raid=r5RAID-6 raid=

Strany 82

Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.The pdisk=<PDISK

Strany 83

Table 103. Write Policy ParametersWrite Policy writepolicy=wb | wt | wc | fwb | nwc Parameter SpecificationWrite-back cache writepolicy=wbWrite-throug

Strany 84

rebuildrate=<rate> clearredundantpath=clear abortcheckconsistencyonerror=<enabled | disabled> loadbalance=<auto | disabled> allowrev

Strany 85

NOTE: If you set escrow=yes, specify the escrow file path.Omconfig Change Encryption KeyDescriptionChanges the encryption key for the controller, if p

Strany 86

Example to Set the reconstruct rate to 50 on controller 1.Exampleomconfig storage controller action= setreconstructrate controller=1 rate=50Omconfig S

Strany 87

Omconfig Import Foreign ConfigurationDescriptionImports all virtual disks that reside on physical disks newly attached to the controller.Syntax omconf

Strany 88

spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours), where id is the controller ID as reported by the omreport storage cont

Strany 89

Omconfig Create CachecadeDescriptionCreates a cachecade on the given controller.Syntaxomconfig storage controller action=createcachecade controller=id

Strany 90 - Default Warning Thresholds

The CLI responds with the following message:Asset information set successfully.When you type omconfig system assetinfo -?, the help that displays prov

Strany 91

Example to Convert multiple non-RAID to RAID on controller 0.Example omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3O

Strany 92

Example for SCSI, SATA, and ATA controllers omconfig storage enclosure action=enablealarm controller=1 enclosure=2Example for SAS controllers omconfig

Strany 93

Example for SCSI, SATA, and ATA controllers omconfig storage enclosure action=setassetname controller=1 enclosure=2 assetname=encl43Example for SAS co

Strany 94

Omconfig Set All Temperature Probe ThresholdsTable 111. Omconfig Set All Temperature Probe ThresholdsDescription Sets the minimum and maximum warning

Strany 95

Omconfig Battery CommandsThe following table displays the omconfig command syntax required to execute battery tasks.Table 114. Omconfig Battery Comman

Strany 96

Table 117. Omconfig Global CommandsRequired Command Levels (1, 2, 3)Optional name=value pairsomconfig storage globalinfoaction=enablestsaction=disable

Strany 97

Omconfig Global Rescan ControllerDescription Rescans all the controllers on the system. For more information about Global Rescan Controller, see the D

Strany 98 - Usage Of Dracusergroup=custom

NOTE: This command is not supported on SAS controllers.Syntaxomconfig storage connector action=rescan controller=id connector=id, where id is the cont

Strany 99

Example to Unblinks the physical disk in cachecade 4 on controller 1Exampleomconfig storage cachecade action=unblink controller=1 cachecade=4Omconfig

Strany 100

Example omconfig storage cachecade action=rename controller=1 cachecade=4 name=cc4Omconfig PCIe SSD CommandsThe following table displays the omconfig

Strany 101 - Omconfig Preferences

3omreport: Viewing System Status Using The Instrumentation ServiceThe omreport command allows you to see detailed information about the system compone

Strany 102 - Omconfig Preferences Messages

Example to Reactivate the specified PCIe SSD device.Example omconfig storage pciessd action=reactivate subsystem=2 pciedevice=0:2:0 force=yesOmconfig

Strany 103 - Defining Alert Actions

Omconfig Fluid Cache Disk CommandThe following section provide the omconfig command syntax required to execute the fluid cache disk task.Table 124. Om

Strany 105

9Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command output in various ways. This chapter expl

Strany 106 - Example Fan Probe Actions

Writing Command Output To A FileWhen redirecting command results to a file, you can specify a filename (and a directory path if necessary) to which yo

Strany 107 - Commands For Clearing Logs

Maximum Warning Threshold : 5500RPMMinimum Failure Threshold : 500RPMMaximum Failure Threshold : 6000RPMYou cannot refer to the previous command resul

Strany 108 - Platformevents

Minimum Failure Threshold: 500RPMMaximum Failure Threshold: 6000RPMYou can use a text editor to insert the time that each block of data was captured.

Strany 109

No special formatting option is required because list format is the default display format. The network data part of the example system summary is dis

Strany 110

Custom Delimited Format (cdv)Use the cdv formatting option to report exported data in custom delimited format. You can specify this option with any om

Strany 111 - Severity

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Strany 112

Command Summary Of The omreport CommandDepending on the system configuration, the results of the omreport command vary from one system to another. Dat

Strany 113 - Example Recovery Commands

Command Level 1Command Level 2Command Level 3User Privilege RequiredUseNonmasking Interrupt (NMI) button (if present on the system), are enabled or di

Strany 114 - Thrmshutdown

Command Level 1Command Level 2Command Level 3User Privilege RequiredUsevolts U, P, A Displays the status and thresholds for the system voltage sensors

Strany 115

Command Level 1Command Level 2Command Level 3User Privilege RequiredUsethrmshutdownP, A Displays how to perform the shutdown action, if any, when a te

Strany 116

Attribute : Express Service CodeValue : 18955029124CMC InformationAttribute : ProductValue : Chassis Management Controller (CMC)Attribute : Descri

Strany 117

Contains:Instrumentation Service 7.x.xStorage Management 4.x.xSun Java Runtime Environment 1.x.x_xxSecure Port Server 7.x.xServer Administrator Core F

Strany 118

Redundancy Status : FullNumber of devices required for full redundancy: 2Redundancy Mode :Redundancy Configuration : Input Source Line 1, upon redund

Strany 119

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.To view the BI

Strany 120

Parameter DescriptionDual NIC (1/2) Displays whether NIC 1 and NIC 2 with PXE/iSCSI is enabled or disabled.Dual NIC (3/4) Displays whether NIC 3 and N

Strany 121 - Adding Lease Information

Parameter DescriptionOptical Drive Controller Displays whether the optical drive controller is enabled or disabled.Parallel port address Displays whet

Strany 122

Contents1 Introduction... 11What's New

Strany 123 - Adding Outsource Information

Group DescriptionEmbedded Server ManagementSets up the Embedded Server Management options.Integrated Devices Controls the devices integrated on the sy

Strany 124 - Adding Owner Information

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.NOTE: If iDRAC

Strany 125 - Adding Support Information

Probe Name : System Board Power Optimized Status : NormalCause : [N/A]Omreport Chassis Info Or Omreport Mainsystem InfoUse the omreport chassis info o

Strany 126 - Adding System Information

Probe Name : Intrusion State : Chassis is closedOmreport Chassis Leds Or Omreport Mainsystem LedsUse the omreport chassis leds or omreport mainsyste

Strany 127 - Adding Warranty Information

Error Correction : Multibit ECCTotal of Memory Array(s)Total Installed Capacity : 65536 MBTotal Installed Capacity Available to the OS : 64386 MBTot

Strany 128

If you specify the index, Server Administrator displays a summary for a specific memory module displaying the health, status, device name, type, speed

Strany 129 - CLI Command Syntax

oromreport mainsystem nics config=team index=nNOTE: This command is applicable only if Team interface is configured in the system. Team interface is c

Strany 130 - Syntax Of Command Elements

Server Administrator displays values for the following fields: Index, Status, Connector Name, Processor Brand, Processor Version, Current Speed, State

Strany 131

The following fields are defined for a cache present on a particular microprocessor. If the cache is internal to the processor, the fields do not appe

Strany 132

Field DescriptionCache Device Supported TypeType of static random access memory (SRAM) that the device can support.Cache Device Current Type Type of t

Strany 133 - Omreport Storage Commands

Omreport Chassis Processors Or Omreport Mainsystem Processors...36Omreport Chassis Pwrmanagement Or Omreport Main

Strany 134 - Omreport Physical Disk Status

The following is an example output:Power Inventory and Budget Power Inventory System Idle Power : 92 W System Maximum Potential Power : 344 WPower B

Strany 135 - Omreport Enclosure Status

NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that support PMB

Strany 136 - Omreport Fan Status

Peak Reading : 2.5 ANOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems t

Strany 137 - Omreport Power Supply Status

name=value pair Descriptionconfig=serial Reports serial port information for BMC or remote access.config=serialoverlanReports BMC/iDRAC or remote acce

Strany 138 - Omreport EMM Status

State : PresentAvailable Size : 472 MBStorage Size : 512 MBOmreport Chassis Slots Or Omreport Mainsystem SlotsUse the omreport chassis slots or omr

Strany 139 - Omreport Global Information

oromreport mainsystem volts index=nThe index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status

Strany 140 - Omreport PCIe SSD Status

If the system has both a main system chassis or main system and at least one direct attached storage device, Server Administrator may display a summar

Strany 141 - Omreport Fluid Cache Status

Alert actions determine how Server Administrator responds when a component has a warning or failure event.The omreport system alertaction or omreport

Strany 142 - Omreport Storage Tape

• Physical Disk Warning• Physical Disk Failure• Virtual Disk Warning• Virtual Disk Failure• Enclosure Warning• Enclosure Failure• Storage Controller B

Strany 143 - Omconfig Storage Commands

Disable: Informational, Warning, and Critical---------------------Removable Flash Media---------------------SettingsEnable: Informational, Warning and

Strany 144 - Omconfig Blink Physical Disk

Omconfig Chassis Leds Or Omconfig Mainsystem Leds...86Omconfig Chassis Memorymode Or Omconfig

Strany 145

Disable: None-----------Fans Group----------SettingsEnable: Informational, Warning, and CriticalDisable: None-----------Individual Objects-----------S

Strany 146

Output Attributes DescriptionDestination Number: Destination 2destination 2: Displays the second destination.Example:110.120.130.140: IPv4 address of

Strany 147

NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.Omreport Syste

Strany 148 - Omconfig Online Physical Disk

: Data Engine x.x.x : Hardware Application Programming Interface x.x.x : Instrumentation Servicex.x.x : Instrumentation Service Integration Layer x.x.

Strany 149

Express Service Code 26790524560Slot Number Slot =8Slot Name SLOT-02Form Factor 1U Half WidthNode Id CB2DX1ScRemote Access Information Remote Access

Strany 150 - Omconfig Clear Physical Disk

Version : 1.50.50 (Build 3)Firmware Information Name : Lifecycle Controller 2Version : 1.3.0.518--------------- Remote Access Controller ----------

Strany 151

System Attributes• Host Name• System Location• Life Cycle ControllerMain System Chassis Or Main SystemChassis• Chassis Model• Chassis Service Tag• Exp

Strany 152

• BIOS Version• Release DateFirmware• Name• VersionNetwork DataThe following details are listed for each NIC and Team interface, if Team interface is

Strany 153

The output that is displayed in the CLI window depends on the version of the BIOS, RAID controllers, and firmware installed on the system. The followi

Strany 154 - Omconfig Check Consistency

Table 17. Valid Parameters Of Omreport Preferences Webservername=value pair Descriptionattribute=geturl Reports the URL information of the Web server.

Strany 155

Adding Support Information... 125Example Com

Strany 157

4Omconfig: Managing Components Using The Instrumentation ServiceThe omconfig command allows you to provide values that define warning events, configur

Strany 158 - Omconfig Delete Virtual Disk

omconfig Command SummaryThe following table provides a high-level summary of the omconfig command. The columns titled Command level 2 and Command leve

Strany 159 - Omconfig Format Virtual Disk

Command Level 1Command Level 2Command Level 3User Privilege RequiredUsealertlog P, A Allows the administrator to clear the alert log.assetinfo P, A En

Strany 160 - Omconfig Secure Virtual Disk

Command Level 1Command Level 2Command Level 3User Privilege RequiredUse(DDDC) memory modes, and also specify which mode to use.pwrmanagementP, A Allow

Strany 161 - Omconfig Rename Virtual Disk

Command Usage Descriptionomconfig system shutdown -?To display the list of valid parameters for omconfig system shutdown.omconfig system alertaction -

Strany 162

Secure Port Server 1.x.xServer Administrator Framework 6.x.xAgent for Remote Access 1.x.xStorage Management 3.x.x Sun Java Runtime Environment 1.x.xxO

Strany 163 - Omconfig Controller Commands

name=value pair 1 attribute= name=value pair 2 setting= Description• immediate: System returns to previous state immediately.• timedelay <value>

Strany 164

name=value pair 1 attribute= name=value pair 2 setting= DescriptionNOTE: On Linux systems, user or user groups upgraded to administrator or administra

Strany 165 - Omconfig Rescan Controller

name=value pair 1 attribute= name=value pair 2 setting= Description• disabled: Disables XD support on system.attribute=cpucore setting=1 | 2 | 4 | 6 |

Strany 166

Omconfig Online Physical Disk... 148Omconfig Assign Glo

Strany 167

name=value pair 1 attribute= name=value pair 2 setting= Description• nic1isci: Enables iSCSI on the first NIC and none (no PXE or iSCSI) on the second

Strany 168

name=value pair 1 attribute= name=value pair 2 setting= Description• 19200: Sets the console redirection failsafe baud rate to 19200 bits per second.•

Strany 169 - Table 93. Size Parameter

name=value pair 1 attribute= name=value pair 2 setting= Description• disabled: Disables the first NIC during system boot.• enabledonly: Enables the fi

Strany 170 - Controller=id

name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=nic4 setting=enabled | enabledwithpxe | disabled | enabledonly | enabledn

Strany 171 - Table 99. Size Parameter

name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=primaryscsi setting=on | off force=trueCAUTION: If you modify the setting

Strany 172 - Cachepolicy=<d

name=value pair 1 attribute= name=value pair 2 setting= Description• auto: Automatically enables the SATA port.attribute=secondaryscsi setting=on | of

Strany 173

name=value pair 1 attribute= name=value pair 2 setting= Description• com1bmc: Maps serial port 1 to COM port 1 bmc.NOTE: This command is applicable on

Strany 174

name=value pair 1 attribute= name=value pair 2 setting= DescriptionNOTE: Depending on the system's hardware you can configure either usb or usbb.

Strany 175 - Omconfig Set Reconstruct Rate

Group name=value pair 1 attribute= name=value pair 2 setting=attribute=InternalUsb1 setting=On | Offattribute=InternalUsb2 setting=On | Offattribute=I

Strany 176

Group name=value pair 1 attribute= name=value pair 2 setting=Processor Settingsattribute=DataReuse setting=Enabled | Disabledattribute=DcuIpPrefetcher

Strany 177

Omconfig Reset Controller Configuration... 166omconfig Create Virtual Dis

Strany 178 - Omconfig Stop Patrol Read

Group name=value pair 1 attribute= name=value pair 2 setting=attribute=ProcVirtualization setting=Enabled | Disabledattribute=QpiBandwidthPriority set

Strany 179 - Omconfig Rekey LKM Controller

Group name=value pair 1 attribute= name=value pair 2 setting=attribute=SataPortG setting=Off | Autoattribute=SataPortGCapacity setting=<string>a

Strany 180 - Omconfig Enclosure Commands

Group name=value pair 1 attribute= name=value pair 2 setting=attribute=MemVoltsetting=AutoVolt | Volt15V | Volt135VNOTE: Volt15V represents 1.5 Volt a

Strany 181

Omconfig Chassis Currents Or Omconfig Mainsystem CurrentsNOTE: This command is no longer available through Server Administrator.Omconfig Chassis Fans

Strany 182

oromconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160When you issue the command and the system sets the values you specify, the fol

Strany 183 - Omconfig Blink

name=value pair 1 name=value pair 2Descriptionpowerbutton=enable | disableNA• true: Enables the Power button on the system.• false: Disables the Power

Strany 184 - Omconfig Global Commands

oromconfig mainsystem info index=0 tag=buildsysIndex 0 always defaults to the main system chassis. The following command omits index=n, but accomplish

Strany 185

Spare mode disables a bank of system memory in which a correctable memory event is detected, enables the spare bank, and copies all the data from the

Strany 186 - Omconfig Connector Commands

name=value pair 1 Descriptionadvanced ECC (advecc): Enables the two DRAM controllers to combine in 128-bit mode and provide optimized reliability. Mem

Strany 187 - Omconfig Cachecade Commands

name=value pair 1 name=value pair 2 Descriptionpower management controlled by the operating system.custom: This profile allows you to configure indivi

Strany 188 - Omconfig Rename Cachecade

Omconfig Set Hot Spare Protection Policy... 186Omconfig Connector Commands

Strany 189 - Omconfig PCIe SSD Commands

Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoringname=value pair 1 name=value pair 2 Descriptionindex=

Strany 190 - Omconfig Partition Command

Omconfig Chassis Remoteaccess Or Omconfig Mainsystem RemoteaccessUse the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to c

Strany 191

name=value pair 1 config=name=value pair 2 DescriptionNOTE: The enablenic option is supported on PowerEdge 9G systems that have DRAC 5 installed.nicse

Strany 192

name=value pair 1 config=name=value pair 2 DescriptionNOTE: The failovernw option is supported on PowerEdge12G systems onward. Configure both primaryn

Strany 193

name=value pair 1 config=name=value pair 2 Descriptionvlanpriority=numbernumber: Priority of virtual LAN identification in the range of 0 to 7.privile

Strany 194

name=value pair 1 config=name=value pair 2 Descriptionmodembasic | modemterminal | modembasicterminalnumber of text commands over a serial connection.

Strany 195

name=value pair 1 config=name=value pair 2 Descriptionoperator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Op

Strany 196 - List (lst)

name=value pair 1 config=name=value pair 2 Descriptionenableserialoverlan=true: Enables serial over LAN.enableserialoverlan=false: Disables serial ove

Strany 197 - Table (tbl)

name=value pair 1 config=name=value pair 2 Descriptiondracusergroup=custom: Enables the Custom User privileges.NOTE: For more information on dracuserg

Strany 198 - Custom Delimited Format (cdv)

name=value pair 1name=value pair 2 name=value pair 3 Descriptionaccessvirtualmedia=true | falsetrue or false: Enables or disables access to virtual me

Komentáře k této Příručce

Žádné komentáře