Dell PowerEdge C5125 Jak používat Strana 15

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 14
15
Table 1-5. Blinking Fault LED Conditions
Index Sensor Name Event Triggers
1 CPU0_Temp,
Upper Critical Going High.
Upper Non-Critical Going High.
Ambient0_Temp,
DIMM Local Temp,
Rear Temp 1
Rear Temp 2
Rear Temp 3
2 BMC Watchdog
•Time expired
•Hard reset
•Power down
Power cycle
3 Processor Thermal trip
4 BMC SEL
•SEL almost full
•SEL Full
5 Processor Hot State Asserted
6 POST Error System firmware error
7 Critical Interrupt PCI SERR
8 DIMM-A0
•Correctable error
•Uncorrectable error
Correctable ECC error logging limit reached
DIMM-B0
DIMM-A1
DIMM-B1
9 SYS FAN 1 ~
SYS FAN 8
Lower critical going low
Lower non-critical going low
10 PSU 1 Status
PSU 2 Status
Presence detected
TEMPERATURE Failure detected
•IOUT Failure detected
•VOUT Failure detected
•FANS Failure detected
INPUT Failure detected
Zobrazit stránku 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 55 56

Komentáře k této Příručce

Žádné komentáře