Dell PowerEdge C5125 Jak používat Strana 22

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 21
22
FAN Control and Monitoring
The BMC receives all fan tachometers of the threshold base from the chassis
controller. The following is the table of the fan speed thresholds.
8 Sled SKU
12 Sled SKU
Table 1-10. 8 Sled SKU Fan Thresholds
Fan Sensor Sensor
Number
LCT LNCT UNCT UCT
SYS FAN 1 68h 0rpm 660rpm N/A N/A
SYS FAN 2 69h 0rpm 660rpm N/A N/A
SYS FAN 3 6Ah 0rpm 660rpm N/A N/A
SYS FAN 4 6Bh 0rpm 660rpm N/A N/A
SYS FAN 5 6Ch 0rpm 660rpm N/A N/A
SYS FAN 6 6Dh 0rpm 660rpm N/A N/A
SYS FAN 7 6Eh 0rpm 660rpm N/A N/A
SYS FAN 8 6Fh 0rpm 660rpm N/A N/A
Table 1-11. 12 Sled SKU Fan Thresholds
Fan Sensor Sensor
Number
LCT LNCT UNCT UCT
SYS FAN 1 68h 0rpm 1140rpm N/A N/A
SYS FAN 2 69h 0rpm 1140rpm N/A N/A
SYS FAN 3 6Ah 0rpm 1140rpm N/A N/A
SYS FAN 4 6Bh 0rpm 1140rpm N/A N/A
SYS FAN 5 6Ch 0rpm 1140rpm N/A N/A
SYS FAN 6 6Dh 0rpm 1140rpm N/A N/A
SYS FAN 7 6Eh 0rpm 1140rpm N/A N/A
SYS FAN 8 6Fh 0rpm 1140rpm N/A N/A
Zobrazit stránku 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 55 56

Komentáře k této Příručce

Žádné komentáře