Dell Force10 S4810P Uživatelská příručka Strana 168

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 175
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 167
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on the S-Series.
ethernet cfm mep
Create an MEP.
S4810
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-
name name mepid mep-id
Parameters
[up-mep |
down-mep]
Specify whether the MEP is up or down facing.
Up-MEP: monitors the forwarding path internal to a
bridge on the customer or provider edge; on Dell
Networking systems, the internal forwarding path is
effectively the switch fabric and forwarding engine.
Down-MEP: monitors the forwarding path external to
another bridge.
domain [name |
level]
Enter the keyword domain and then enter the domain name
or domain level.
ma-name
name
Enter the keyword ma-name and then enter the name of the
maintenance association.
mepid mep-id Enter an MEP ID. The range is from 1 to 8191.
Defaults none
Command
Modes
INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
168
802.1ag
Zobrazit stránku 167

Komentáře k této Příručce

Žádné komentáře