Dell OpenManage Server Administrator Version 2.3 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Software Dell OpenManage Server Administrator Version 2.3. Dell OpenManage Server Administrator Version 2.3 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 216
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User's Guide

www.dell.com | support.dell.comDell OpenManage™Server AdministratorVersion 2.3Command Line InterfaceUser's Guide

Strany 2 - Notes and Notices

10 Contentsomconfig Battery Commands . . . . . . . . . . . . . . . . . . . . . . . . . 165omconfig Recondition Battery . . . . . . . . . . . . . .

Strany 3 - Contents

100 omconfig: Managing Components Using the Instrumentation ServiceTable 6-14 shows the valid parameters for the command.When you type omconfig prefer

Strany 4 - Instrumentation Service

omconfig: Managing Components Using the Instrumentation Service 101omconfig systemUse the omconfig system commands to clear logs, determine how variou

Strany 5

102 omconfig: Managing Components Using the Instrumentation ServiceAvailable Alert ActionsTable 6-16 shows the alert actions for each component that a

Strany 6

omconfig: Managing Components Using the Instrumentation Service 103Example Set Alert Action CommandsThe examples below are valid example commands. For

Strany 7

104 omconfig: Managing Components Using the Instrumentation ServiceExample Chassis Intrusion ActionsTo clear all alert actions for chassis intrusion,

Strany 8 - 8 Contents

omconfig: Managing Components Using the Instrumentation Service 105omconfig system platformeventsUse the omconfig system platformevents command to con

Strany 9

106 omconfig: Managing Components Using the Instrumentation Serviceevent=intrusion Sets action or enables/disables alert generation when a chassis ha

Strany 10 - 10 Contents

omconfig: Managing Components Using the Instrumentation Service 107omconfig system eventsUse the omconfig system events command to enable and disable

Strany 11 - Introduction

108 omconfig: Managing Components Using the Instrumentation ServiceSeverityIn the context of configuring events, severity determines how severe an eve

Strany 12 - Primary CLI Commands

omconfig: Managing Components Using the Instrumentation Service 109omconfig system recoveryUse the omconfig system recovery command to set the action

Strany 13 - Success Messages

Introduction 11IntroductionWhether you are using the graphical user interface (GUI) or the command line interface (CLI), Server Administrator performs

Strany 14 - Failure Messages

110 omconfig: Managing Components Using the Instrumentation ServiceExample Shutdown CommandsTo set the shutdown action to reboot, type:omconfig system

Strany 15 - Command Syntax Overview

omconfig system assetinfo: Editing Cost of Ownership Values 111omconfig system assetinfo: Editing Cost of Ownership Values omconfig System Asset Info

Strany 16 - <n> signauth=<

112 omconfig system assetinfo: Editing Cost of Ownership ValuesExample Commands for Adding Acquisition InformationTo provide a value for an acquisitio

Strany 17 - Example Help Commands

omconfig system assetinfo: Editing Cost of Ownership Values 113Adding Depreciation InformationDepreciation is a set of methods for computing the deval

Strany 18 - [name=value pair 2]

114 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Extended Warranty InformationUse the omconfig system extwarranty command to assi

Strany 19

omconfig system assetinfo: Editing Cost of Ownership Values 115Adding Lease InformationA lease is an agreement to pay for the use of a system for a sp

Strany 20

116 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Maintenance InformationMaintenance refers to activities required to keep the sys

Strany 21

omconfig system assetinfo: Editing Cost of Ownership Values 117Adding Outsource InformationOutsourcing is the practice of contracting with another bus

Strany 22

118 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Owner InformationThe owner is the party that holds legal property title to the s

Strany 23

omconfig system assetinfo: Editing Cost of Ownership Values 119Adding Service Contract InformationA service contract is an agreement that specifies fe

Strany 24

12 IntroductionPrimary CLI CommandsThe commands that carry out the functions of Server Administrator are:•omconfig•omdiag•omhelp•omreportThe omconfig

Strany 25

120 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Support InformationSupport refers to technical assistance that the system user c

Strany 26

omconfig system assetinfo: Editing Cost of Ownership Values 121Adding System InformationSystem information includes the primary user of the system, th

Strany 27

122 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Warranty InformationUse the omconfig system warranty command to assign values fo

Strany 28

Using the Storage Management Service 123Using the Storage Management ServiceStorage Management has a fully-featured command line interface (CLI) that

Strany 29

124 Using the Storage Management ServiceFollowing the command levels, the omreport and omconfig command syntax may require one or more name=value pair

Strany 30

Using the Storage Management Service 125adisk=<ADISKID> Indicates a particular array disk by specifying either connector:targetID or connector:e

Strany 31

126 Using the Storage Management ServiceUser Privileges for omreport storage and omconfig storageStorage Management requires Administrator privileges

Strany 32

Using the Storage Management Service 127omreport Controller Status omreport Global Information (Smart Thermal Shutdown Status)omreport Battery Status

Strany 33

128 Using the Storage Management Serviceomreport Connector Status omreport Enclosure Status Table 8-7. omreport Connector CommandsRequired Command Lev

Strany 34

Using the Storage Management Service 129omreport Temperature Probe Statusomreport Fan StatusTable 8-9. omreport Temperature Probe CommandsRequired Com

Strany 35

Introduction 13 NOTE: Omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or Server Update Util

Strany 36

130 Using the Storage Management Serviceomreport Power Supply Statusomreport EMM StatusTable 8-11. omreport Power Supply CommandsRequired Command Leve

Strany 37

Using the Storage Management Service 131omreport Array Disk Status controller=id enclosure=idinfo=emms index=nwhere id is the controller number and th

Strany 38

132 Using the Storage Management Serviceomreport Virtual Disk Status omconfig Global CommandsThe following sections provide the omconfig command synta

Strany 39

Using the Storage Management Service 133Example SyntaxThe omconfig command syntax for enabling thermal shutdown does not require that you specify a co

Strany 40

134 Using the Storage Management Serviceomconfig Controller Commands The following sections provide the omconfig command syntax required to execute co

Strany 41

Using the Storage Management Service 135omconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See the online he

Strany 42

136 Using the Storage Management ServiceExample Syntax For example, to enable the alarm on controller 1, enter: omconfig storage controller action=ena

Strany 43

Using the Storage Management Service 137Example Syntax For example, to test the alarm on controller 1, enter: omconfig storage controller action=testa

Strany 44

138 Using the Storage Management ServiceComplete Syntax omconfig storage controller action=createvdisk controller=id raid=<c| r0| r1| r1c| r5| r10|

Strany 45

Using the Storage Management Service 139size=<number | max | min> Parameter (Required) The following table indicates how to specify the size=<

Strany 46

14 IntroductionFailure MessagesCLI failure messages provide reasons why some commands do not succeed. Some common reasons why commands fail include sy

Strany 47

140 Using the Storage Management Service[cachepolicy=<d | c>] Parameter (Optional) Different controllers support different cache policies. See t

Strany 48

Using the Storage Management Service 141[name=<string>] Parameter (Optional) Use this parameter to specify a name for the virtual disk. For exam

Strany 49

142 Using the Storage Management ServiceExample Syntax For example, to set the rebuild rate to 50 on controller 1, enter: omconfig storage controller

Strany 50

Using the Storage Management Service 143Example SyntaxFor example, to set the check consistency rate to 50 on controller 1, enter:omconfig storage con

Strany 51

144 Using the Storage Management Serviceomconfig Clear Foreign ConfigurationUse the following omconfig command syntax to clear or delete all virtual d

Strany 52

Using the Storage Management Service 145omconfig Stop Patrol ReadUse the following omconfig command syntax to stop the patrol read task on the control

Strany 53

146 Using the Storage Management Serviceomconfig Blink Virtual Disk Use the following omconfig command syntax to blink the array disks included in a v

Strany 54

Using the Storage Management Service 147Example Syntax For example, to blink the array disks in virtual disk 4 on controller 1, enter: omconfig storag

Strany 55 - Commands for Viewing Logs

148 Using the Storage Management ServiceExample Syntax For example, to fast initialize virtual disk 4 on controller 1, enter: omconfig storage vdisk a

Strany 56

Using the Storage Management Service 149Complete Syntax omconfig storage vdisk action=restoresegments controller=id vdisk=id where id is the controlle

Strany 57

Introduction 15Scripting and Comparing With the CLIThe Server Administrator CLI allows administrators to write batch programs or scripts to be execute

Strany 58

150 Using the Storage Management ServiceExample Syntax For example, to unmirror virtual disk 4 on controller 1, enter: omconfig storage vdisk action=u

Strany 59

Using the Storage Management Service 151Complete Syntax omconfig storage vdisk action=assigndedicatedhotspare controller=id vdisk=id adisk=<ADISKID

Strany 60 - Example Command Output

152 Using the Storage Management Serviceomconfig Cancel Check Consistency Use the following omconfig command syntax to cancel a check consistency whil

Strany 61 - Main System Chassis

Using the Storage Management Service 153omconfig Resume Check Consistency Use the following omconfig command syntax to resume a check consistency afte

Strany 62 - Firmware

154 Using the Storage Management Serviceomconfig Format Virtual Disk Use the following omconfig command syntax to format a virtual disk. Complete Synt

Strany 63 - Storage Enclosures

Using the Storage Management Service 155omconfig Change Virtual Disk Policy Use the following omconfig command syntax to change a virtual disk’s read,

Strany 64

156 Using the Storage Management Serviceomconfig Array Disk Commands The following sections provide the omconfig command syntax required to execute ar

Strany 65

Using the Storage Management Service 157Example for SAS Controllers: To blink the array disks described in this example, enter: omconfig storage adisk

Strany 66

158 Using the Storage Management ServiceExample Syntax In this example, you want to prepare array disk 3 on connector 0 of controller 1 for removal. O

Strany 67 - Name — Name

Using the Storage Management Service 159omconfig Offline Array Disk Use the following omconfig command syntax to offline an array disk: Complete Synta

Strany 68

16 IntroductionSome commands have command level 1 and command level 2 and one name=value pair. Consider the following example command that instructs S

Strany 69

160 Using the Storage Management Serviceomconfig Online Array Disk Use the following omconfig command syntax to bring an offline array disk back onlin

Strany 70

Using the Storage Management Service 161Example for SCSI, SATA, and ATA Controllers: To assign the array disk described in this example as a global ho

Strany 71

162 Using the Storage Management Serviceomconfig Rebuild Array Disk Use the following omconfig command syntax to rebuild a failed array disk. Rebuildi

Strany 72

Using the Storage Management Service 163Example Syntax In this example, you want to cancel the rebuild or array disk 3 on connector 0 of controller 1.

Strany 73

164 Using the Storage Management Serviceomconfig Clear Array DiskUse the following omconfig command to clear data or a configuration from an array dis

Strany 74

Using the Storage Management Service 165Example Syntax In this example, you want to cancel the clear of array disk 3 on connector 0 of controller 1. O

Strany 75

166 Using the Storage Management Serviceomconfig Start Battery Learn CycleUse the following omconfig command to start the battery learn cycle.Complete

Strany 76

Using the Storage Management Service 167omconfig Connector Commands The following sections provide the omconfig command syntax required to execute con

Strany 77

168 Using the Storage Management Serviceomconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm: Compl

Strany 78

Using the Storage Management Service 169omconfig Disable Enclosure Alarm Use the following omconfig command syntax to disable the enclosure alarm. Com

Strany 79

omhelp: Getting Help With CLI Commands 17omhelp: Getting Help With CLI CommandsThe omhelp command and its equivalent, <command> -?, accesses the

Strany 80

170 Using the Storage Management Serviceomconfig Set Enclosure Asset Tag Use the following omconfig command syntax to specify the enclosure’s asset ta

Strany 81 - : Do not allow writes. Make

Using the Storage Management Service 171Example for SAS Controllers: For example, to specify the asset name for enclosure 3 attached to connector 2 on

Strany 82

172 Using the Storage Management Serviceomconfig Reset Temperature Probe Thresholds Use the following omconfig command syntax to reset the minimum and

Strany 83

Using the Storage Management Service 173Example Syntax For example, you may want to specify the minimum and maximum warning thresholds for all tempera

Strany 84

174 Using the Storage Management ServiceExample for SAS Controllers In this example, the temperature probes reside in enclosure 3 attached to connecto

Strany 85

Working With CLI Command Results 175Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use command output in

Strany 86

176 Working With CLI Command ResultsSave Command Results to a File That Can Be OverwrittenUse the -outc option when you want to overwrite data that is

Strany 87

Working With CLI Command Results 177Ty p e :omreport chassis fans index=0 -outa fans.txtFans.txt now reads as follows:You can use a text editor to ins

Strany 88

178 Working With CLI Command ResultsSyntax for the formatting option is:<command> -fmt <format option>For example, type:omreport system su

Strany 89

Working With CLI Command Results 179The example output displays as follows:------------------------------Network Interface Card 0 Data----------------

Strany 90

18 omhelp: Getting Help With CLI CommandsFigure 2-1. Different Levels of Help for a CommandYou can also parse the omconfig system assetinfo command as

Strany 91

180 Working With CLI Command ResultsCustom Delimited Format (cdv)Use the cdv formatting option to report exported data in custom delimited format. You

Strany 92

Glossary 181GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in Dell user documents.AAbbreviation fo

Strany 93

182 Glossaryadministrators who do not want define one set of privileges for users in the operating system and a separate set of users and accounts for

Strany 94

Glossary 183busAn information pathway between the components of a computer. Your computer contains an expansion bus that allows the microprocessor to

Strany 95

184 GlossaryCMOSAcronym for complementary metal-oxide semiconductor. In computers, CMOS memory chips are often used for NVRAM storage.COMnThe device n

Strany 96

Glossary 185cursorA marker, such as a block, underscore, or pointer that represents the position at which the next keyboard or mouse action will occur

Strany 97

186 GlossaryDPMSAbbreviation for Display Power Management Signaling. A standard developed by the Video Electronics Standards Association (VESA®) that

Strany 98

Glossary 187EMIAbbreviation for electromagnetic interference.EMMAbbreviation for expanded memory manager. A utility that uses extended memory to emula

Strany 99

188 Glossaryflash biosA PC BIOS that is stored in flash memory rather than in a ROM. A flash BIOS chip can be updated in place, whereas a ROM BIOS mus

Strany 100

Glossary 189HPFSAbbreviation for the High Performance File System option in the Windows NT and later Windows operating systems.HTTPSAbbreviation for H

Strany 101 - Defining Alert Actions

omdiag: Using the Diagnostic Service 19omdiag: Using the Diagnostic ServiceThe omdiag command allows you to test chassis and storage components such a

Strany 102 - Available Alert Actions

190 GlossaryISAAcronym for Industry-Standard Architecture. A 16-bit expansion bus design. The expansion-card connectors in an ISA computer are also co

Strany 103

Glossary 191LS driveA drive that uses laser servo technology to read LS 120 diskettes that hold up to 120 MB of data as well as standard 3.5-inch disk

Strany 104 - Commands for Clearing Logs

192 GlossaryMIFAcronym for management information format. A MIF file contains information, status, and links to component instrumentation. MIF files a

Strany 105

Glossary 193NVRAMAcronym for nonvolatile random-access memory. Memory that does not lose its contents when you turn off your computer. NVRAM is used f

Strany 106

194 GlossaryPLCCAcronym for plastic leaded chip carrier.Plug and PlayAn industry-standard specification that makes it easier to add hardware devices t

Strany 107

Glossary 195QFPAcronym for quad flat pack.RACAcronym for remote access controller. Dell OpenManage Server Administrator supports all RACs. These inclu

Strany 108 - Severity

196 GlossaryROMAcronym for read-only memory. Your computer contains some programs essential to its operation in ROM code. Unlike RAM, a ROM chip retai

Strany 109 - Example Recovery Commands

Glossary 197SIMMAcronym for single in-line memory module. A small circuit board containing DRAM chips that connects to the system board.SIPAcronym for

Strany 110 - Example Shutdown Commands

198 Glossarysystem boardAs the main circuit board, the system board usually contains most of your computer's integral components, such as the fol

Strany 111 - Ownership Values

Glossary 199• LowerThresholdNon-critical• LowerThresholdCritical• LowerThresholdFataltime-outA specified period of system inactivity that must occur b

Strany 112

Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either pot

Strany 113

20 omdiag: Using the Diagnostic Servicesystem any level 3 command for chassis or storageRuns the test for specified chassis or storage component.passe

Strany 114

200 Glossarythat uniquely identifies an enterprise, as well as the formula for specifying a unique identifier for the objects defined in that enterpri

Strany 115 - Adding Lease Information

Glossary 201video resolutionVideo resolution—800 x 600, for example—is expressed as the number of pixels across by the number of pixels up and down. T

Strany 116

202 Glossarywrite-protectedRead-only files are said to be write-protected. You can write-protect a 3.5-inch diskette by sliding its write-protect tab

Strany 117 - Adding Outsource Information

Index 203IndexSymbols-?omconfig, 78omconfig chassis, 80omdiag chassis, 22omdiag storage, 29omdiag system, 35omreport, 41request for help, 17Aaboutomco

Strany 118 - Adding Owner Information

204 Index204 Indexbaud rate testomdiag chassis serialport, 28biosomreport chassis, 43biossetupomconfig chassis, 80omreport chassis, 44blinkomconfig, 1

Strany 119

Index 205cancel clear array diskomconfig, 164cancel initialize diskomconfig, 147cancel rebuild array diskomconfig, 162CD drive diagnostics, 29cddvd, 2

Strany 120 - Adding Support Information

206 Index206 Indexconnector nameomreport chassis processors, 51connector statusomreport, 128controllerbattery, 127-128BMC, 38, 45, 59, 77display IDs,

Strany 121 - Adding System Information

Index 207external clock speedomreport chassis processors, 51external nameomreport chassis ports, 50extremity seek testomdiag storage floppy, 31extremi

Strany 122 - Adding Warranty Information

208 Index208 IndexLlease information, 115ledsomconfig chassis, 95omreport chassis, 49levels of help for a CLI command, 18linear seek testomdiag storag

Strany 123 - CLI Command Syntax

Index 209omconfig (continued)offline array disk, 159online array disk, 160pause check consistency, 152prepare to remove array disk, 157quiet controlle

Strany 124

omdiag: Using the Diagnostic Service 21omdiag aboutUse the omdiag about command to learn the product name and version number of the systems management

Strany 125

210 Index210 Indexomconfig storageadisk, 123, 156battery, 165connector, 167controller, 134enclosure, 167globalinfo, 132vdisk, 145omconfig systemalerta

Strany 126

Index 211omdiag chassis usbctrlUSB node detection test, 29omdiag storage, 29-?, 29cddvd, 29floppy, 30idedevdiag, 31raidctrl, 31scsidevdiag, 34omdiag s

Strany 127

212 Index212 Indexomreport chassis processorscache properties, 51connector name, 51core count, 51current speed, 51external clock speed, 51manufacturer

Strany 128

Index 213PCI diagnostics, 27pedestinationsomconfig system, 104omreport system, 58platformeventsomconfig system, 105omreport system, 59port typeomrepor

Strany 129

214 Index214 Indexservice contract information, 119adding, 119set enclosure asset nameomconfig, 170set enclosure asset tagomconfig, 170set temperature

Strany 130

Index 215thrmshutdownomconfig system, 110omreport system, 63timer testLSI RAID controller hardware test, 32Uunassign dedicated hot spareomconfig, 150u

Strany 131

216 Index216 Index

Strany 132 - Complete Syntax

22 omdiag: Using the Diagnostic Serviceomdiag about details=trueUse the omdiag about details=true command to see information about all of the Server A

Strany 133 - Example Syntax

omdiag: Using the Diagnostic Service 23omdiag chassis memoryUse the omdiag chassis memory command to test the system's RAM. The following test is

Strany 134

24 omdiag: Using the Diagnostic Service– S-Registers Test — Uses the selected range of S-Registers to exercise and diagnose the functionality of the m

Strany 135

omdiag: Using the Diagnostic Service 25• The following tests are available on Dell supported Broadcom NICs:– BRCMNetwork Control Registers Test — Test

Strany 136

26 omdiag: Using the Diagnostic Service NOTE: The following tests are only available on systems running a supported Microsoft Windows operating syste

Strany 137

omdiag: Using the Diagnostic Service 27– FIFO Test Mode (test mode to determine FIFO depth)– Configuration Mode (cnfgX registers are available) NOT

Strany 138

28 omdiag: Using the Diagnostic Serviceomdiag chassis racUse the omdiag chassis rac command to run the tests on the remote access controller (RAC).The

Strany 139

omdiag: Using the Diagnostic Service 29omdiag chassis usbctrlUse the omdiag chassis usbctrl command to test the USB controller(s). The USB test perfor

Strany 140

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11What's New for Version 2.3 . . . . . . .

Strany 141

30 omdiag: Using the Diagnostic ServiceThe CD/DVD drive test performs the following tests: • Extremity Test — Conducts negative testing on the drive.

Strany 142

omdiag: Using the Diagnostic Service 31• Extremity Test — Attempts to access sectors beyond the range and confirms the error received.• Read-Write Tes

Strany 143

32 omdiag: Using the Diagnostic ServiceYou must stop an application that reserves the RAID controller before you attempt to run the Adaptec RAID contr

Strany 144

omdiag: Using the Diagnostic Service 33The diagnostics resume when the hard drive I/O activity has decreased. If the following message appears:Device

Strany 145

34 omdiag: Using the Diagnostic Serviceomdiag storage scsidevdiagUse the omdiag storage scsidevdiag command to test the SCSI controller, connected har

Strany 146

omdiag: Using the Diagnostic Service 35• SCSI Tape Library/Changer Tests — Performs several tests on a SCSI tape library or changer, which is connecte

Strany 147

36 omdiag: Using the Diagnostic Service

Strany 148

omreport: Viewing System Status Using the Instrumentation Service 37omreport: Viewing System Status Using the Instrumentation ServiceThe omreport comm

Strany 149

38 omreport: Viewing System Status Using the Instrumentation ServiceTable 4-1 is a high-level summary of the omreport command. The column titled "

Strany 150

omreport: Viewing System Status Using the Instrumentation Service 39fru U, P, A Shows the Field Replaceable Unit (FRU) information.info U, P, A Shows

Strany 151

4 Contentsomdiag storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29omdiag storage -?. . . . . . . . . . . . . . . . . . .

Strany 152

40 omreport: Viewing System Status Using the Instrumentation Serviceassetinfo U, P, A Shows cost of ownership information for your system.cmdlog U, P,

Strany 153

omreport: Viewing System Status Using the Instrumentation Service 41Help With the omreport CommandUse the omreport -? command to get a list of the ava

Strany 154

42 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis CommandsUse omreport chassis commands to view details for the ent

Strany 155

omreport: Viewing System Status Using the Instrumentation Service 43omreport chassis acswitchUse the omreport chassis acswitch command if your system

Strany 156

44 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis biossetupUse the omreport chassis biossetup command to view BIOS

Strany 157

omreport: Viewing System Status Using the Instrumentation Service 45omreport chassis bmcUse the omreport chassis bmc command to view baseboard managem

Strany 158

46 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis currentsUse the omreport chassis currents command to view current

Strany 159

omreport: Viewing System Status Using the Instrumentation Service 47omreport chassis frontpanelUse the omreport chassis frontpanel command to view whe

Strany 160

48 omreport: Viewing System Status Using the Instrumentation ServiceDepending on your configuration, output may resemble the following example:omrepor

Strany 161

omreport: Viewing System Status Using the Instrumentation Service 49omreport chassis ledsUse the omreport chassis leds command to find out whether cle

Strany 162

Contents 5omreport chassis pwrsupplies . . . . . . . . . . . . . . . . . . . . . . . 53omreport chassis slots . . . . . . . . . . . . . . . . . . .

Strany 163

50 omreport: Viewing System Status Using the Instrumentation ServiceIf your system supports redundant memory, the redundancy output may resemble the f

Strany 164

omreport: Viewing System Status Using the Instrumentation Service 51Connector Type refers to the type of plug or cable and plug that connects two devi

Strany 165

52 omreport: Viewing System Status Using the Instrumentation ServiceFields Reported for Each Cache on a Particular ProcessorStatus reports whether a s

Strany 166

omreport: Viewing System Status Using the Instrumentation Service 53omreport chassis pwrsuppliesUse the omreport chassis pwrsupplies command to view p

Strany 167

54 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis voltsUse the omreport chassis volts command to view properties of

Strany 168 - Example for SAS Controllers:

omreport: Viewing System Status Using the Instrumentation Service 55Commands for Viewing LogsYou can use the omreport system command to view logs: the

Strany 169

56 omreport: Viewing System Status Using the Instrumentation ServiceComponents and Events for Which You Can View Alert ActionsYou can view alert actio

Strany 170

omreport: Viewing System Status Using the Instrumentation Service 57omreport system eventsUse the omreport system events command to view the current e

Strany 171

58 omreport: Viewing System Status Using the Instrumentation ServiceExample Command for Event TypeWhen you type:omreport system events type=fansThe fo

Strany 172

omreport: Viewing System Status Using the Instrumentation Service 59 omreport system platformeventsUse the omreport system platformevents command to

Strany 173

6 ContentsHelp With the omconfig Command . . . . . . . . . . . . . . . . . . . . . . . 78omconfig about. . . . . . . . . . . . . . . . . . . . . .

Strany 174

60 omreport: Viewing System Status Using the Instrumentation Serviceomreport system summaryUse the omreport system summary command to view a comprehen

Strany 175

omreport: Viewing System Status Using the Instrumentation Service 61The system summary hardware information includes data values for installed compone

Strany 176

62 omreport: Viewing System Status Using the Instrumentation ServiceMemory• Total installed capacity• Memory available to the operating system• Total

Strany 177

omreport: Viewing System Status Using the Instrumentation Service 63Network Interface Card The following details are listed for each NIC in the system

Strany 178 - Table (tbl)

64 omreport: Viewing System Status Using the Instrumentation Serviceomreport system versionUse the omreport system version command to list the version

Strany 179 - Raw XML (xml)

omreport storage: Using the Storage Reports 65omreport storage: Using the Storage ReportsUse the omreport storage command to view information about en

Strany 180 - Custom Delimited Format (cdv)

66 omreport storage: Using the Storage Reportsomreport storage CommandsWhen you type:omreport storageServer Administrator displays a general status fo

Strany 181 - Glossary

omreport storage: Using the Storage Reports 67omreport storage arraydisksUse the omreport storage arraydisks controller=ID command (where ID is the ID

Strany 182

68 omreport storage: Using the Storage Reportsomreport storage arraysUse the omreport storage arrays command to view detailed information about the di

Strany 183 - Glossary 183

omreport storage: Using the Storage Reports 69• Write Cache — Write policies specify whether the controller sends a write-request completion signal as

Strany 184

Contents 7Adding Depreciation Information . . . . . . . . . . . . . . . . . . . . . . . 113Example Commands for Adding Depreciation Information. . .

Strany 185 - Glossary 185

70 omreport storage: Using the Storage Reportsomreport storage enclosureinfoUse the omreport storage enclosureinfo enclosure=ID command (where ID is t

Strany 186

omreport storage: Using the Storage Reports 71omreport storage enclosuresUse the omreport storage enclosures command to view the enclosures that conta

Strany 187 - Glossary 187

72 omreport storage: Using the Storage Reports• Read Cache — Read policies indicate whether or not the controller should read sequential sectors of th

Strany 188

omreport storage: Using the Storage Reports 73The omreport storage osdiskinfo command provides the following information about the physical array disk

Strany 189 - Glossary 189

74 omreport storage: Using the Storage Reportsomreport storage volumesUse the omreport storage volumes command to view information about the volumes o

Strany 190

omconfig: Managing Components Using the Instrumentation Service 75omconfig: Managing Components Using the Instrumentation ServiceThe omconfig command

Strany 191 - Glossary 191

76 omconfig: Managing Components Using the Instrumentation Serviceomconfig Command Summary NOTE: Although this section lists all possible omconfig co

Strany 192

omconfig: Managing Components Using the Instrumentation Service 77esmlog P, A Allows the administrator to clear the log.events P, A Enables and disabl

Strany 193 - Glossary 193

78 omconfig: Managing Components Using the Instrumentation ServiceHelp With the omconfig CommandUse the omconfig -? command to get a list of the avail

Strany 194

omconfig: Managing Components Using the Instrumentation Service 79To make a file that contains all of the help for the omconfig system alertaction -?

Strany 195

8 Contentsomreport Storage Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126omreport Controller Status. . . . . . . . . . . . . . .

Strany 196

80 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassisUse the omconfig chassis commands to default or to set values for cu

Strany 197 - Glossary 197

omconfig: Managing Components Using the Instrumentation Service 81attribute=dbs setting=enable | disable enable: Enables Demand Based Power Management

Strany 198

82 omconfig: Managing Components Using the Instrumentation Serviceattribute=mouse setting=on | off on: Enable the mouse.off: Disable the mouse.attribu

Strany 199 - • LowerThresholdFatal

omconfig: Managing Components Using the Instrumentation Service 83attribute=primaryscsi setting=on | offforce=trueNOTICE: If you modify the setting fo

Strany 200

84 omconfig: Managing Components Using the Instrumentation Serviceattribute=sataport (0...7) setting=off | auto off: Disable the SATA port.auto: Autom

Strany 201

omconfig: Managing Components Using the Instrumentation Service 85omconfig chassis bmcUse the omconfig chassis bmc command to configure:• The BMC on a

Strany 202

86 omconfig: Managing Components Using the Instrumentation Serviceconfig=nic (continued) ipsource=static | dhcp | systemsoftwarestatic: Static if the

Strany 203 - Index 203

omconfig: Managing Components Using the Instrumentation Service 87config=serial baudrate=9600 | 19200 | 38400 | 576009600: Sets connection speed to 9

Strany 204 - 204 Index

88 omconfig: Managing Components Using the Instrumentation Serviceconfig=serial (continued)privilegelevel=administrator | operator | useradministrator

Strany 205 - Index 205

omconfig: Managing Components Using the Instrumentation Service 89config=terminalmode (continued)echocontrol=enabled | disabled enabled: Enables chara

Strany 206 - 206 Index

Contents 9omconfig Virtual Disk Commands . . . . . . . . . . . . . . . . . . . . . . . 145omconfig Blink Virtual Disk. . . . . . . . . . . . . . . .

Strany 207 - Index 207

90 omconfig: Managing Components Using the Instrumentation Serviceconfig=user id=number enable=true | false id=number: ID number of the user being con

Strany 208 - 208 Index

omconfig: Managing Components Using the Instrumentation Service 91omconfig chassis currentsUse the omconfig chassis currents command to set amperage p

Strany 209 - Index 209

92 omconfig: Managing Components Using the Instrumentation ServiceDefault Minimum and Maximum Warning ThresholdsIf you want to set both the upper and

Strany 210 - 210 Index

omconfig: Managing Components Using the Instrumentation Service 93Default Minimum and Maximum Warning Thresholds NOTE: Systems that contain ESM3 capa

Strany 211 - Index 211

94 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis frontpanelUse the omconfig chassis frontpanel command to configure

Strany 212 - 212 Index

omconfig: Managing Components Using the Instrumentation Service 95For some chassis, you can assign a different name. You cannot rename the main system

Strany 213 - Index 213

96 omconfig: Managing Components Using the Instrumentation ServiceMirroring mode switches to a redundant copy of memory when an uncorrectable memory e

Strany 214 - 214 Index

omconfig: Managing Components Using the Instrumentation Service 97Default Minimum and Maximum Warning Thresholds NOTE: The capabilities for managing

Strany 215 - Index 215

98 omconfig: Managing Components Using the Instrumentation ServiceDefault Minimum and Maximum Warning Thresholds NOTE: Systems that contain ESM3, ESM

Strany 216 - 216 Index

omconfig: Managing Components Using the Instrumentation Service 99Therefore, for a computer named "myOmsa" running Server Administrator, the

Komentáře k této Příručce

Žádné komentáře