106 omconfig: Managing Components Using the Instrumentation Service
event=intrusion Sets action or enables/disables alert generation when a chassis has
been opened.
event=powerwarn Sets action or enables/disables alert generation when a power device
probe detects that the power supply, voltage regulator module, or DC to
DC converter is pending a failure condition.
event=powerfail Sets action or enables/disables alert generation when a power device
probe detects that the power supply, voltage regulator module, or DC to
DC converter has failed.
event=processorwarn Sets action or enables/disables alert generation when a processor probe
detects that the processor is running at less than peak performance
or speed.
event=processorfail Sets action or enables/disables alert generation when a processor probe
detects that the processor has failed.
event=redundegrad Sets action or enables/disables alert generation when the system’s fans
and/or power supplies become inoperative, resulting in less than full
redundancy for that component.
event=redunlost Sets action or enables/disables alert generation when the system’s fans
and/or power supplies become inoperative, resulting in a lost or a "no
redundant components working" condition for that component.
event=tempwarn Sets action or enables/disables alert generation when a temperature
probe detects that the temperature is approaching the maximum high or
low limits.
event=tempfail Sets action or enables/disables alert generation when a temperature
probe detects that the temperature is either too high or low for proper
operation.
event=voltfail Sets action or enables/disables alert generation when a voltage probe
detects that the voltage is too low for proper operation.
event=watchdogasr Enables or disables alert generation configured by the ASR when the
system has hung or is not responding.
Table 6-20. omconfig system platformevents (continued)