Dell™ PowerVault™ 124T LTO6 SAS Autoloader User'sGuide IntroductionInstalling the AutoloaderOperating the AutoloaderRemote Management UnitFront P
If you select an empty location, No Source Tape appears on the LCD. Choose a different location.If you select a location that is already occupied, Des
Outward Side of a MagazineThe autoloader will not run unless both magazine bays are properly occupied with either a magazine or a magazine blank. One
so may cause damage to the magazine or the autoloader.Manually Operating the MagazineThere are tw o white thumbwheels, located on each end of the maga
adhering to the cartridge at any point other than the designated label area.3. Fully insert the cartridge into the slot.When pushing the cartridge in
Viewing Firmware VersionTo view the current firmware version, use the following procedure:1. From the main menu, scroll to Status, and then press Ent
1. From the main menu, scroll to Status, and then press Enter.2. From the Status submenu, scroll to Drive, and then press Enter.3. From the Drive s
Enabling IPv6 Phase 1The PowerVault 124T autoloader is IPv6 Phase 1 enabled by default.Configuring IPv6 Phase 1From the Operator Panel:Select Configur
If you have successfully tested ping6 using scoped link-local addresses, it is possible that you want to use this addresses also for connections toTCP
Back to Contents PageRemote Management Unit: Dell™ PowerVault™ 124TLTO6 SAS Autoloader User's Guide Remote Management Unit Overview Configuration
Use of all RMU web pages features requires Java Script to be enabled in the user's web browser.To open the RMU:1. From your computer, open your
Back to Contents PageInstalling the Autoloader: Dell™ PowerVault™ 124T LTO6 SAS Autoloader User's Guide Installation Overview Product Overview I
4. Administration Lock - provides status regarding RMU security settings. Refer to Client OverlapControl for information on how to configure the Admi
To view the compression setting:From any page, click the Configuration heading. The Configuration screen displays. Under theCompression heading, the c
To set Auto Clean:1. From any page, click the Configuration heading. The Configuration screen displays.2. Scroll to Cleaning Tape.If a check mark ap
or through the RMU. The time zone setting is not lost when powered off.NOTE: Whether the autoloader is connected to a time server or not, if you want
Setting Front Panel Security OptionsWhen you enable the security option, users must enter a password to access the autoloader's front panelfuncti
authorized client list or the overlap control policy.3. Use the drop-down box to select Enable or Disabled.4. Type the IP addresses in the appropria
NOTE: It is recommended that all firmware updated be performed with image files located onthe local system hard drive as opposed to a removable media
3. Specify a loop count, if desired. Valid numbers are 1 to 99.4. Click Submit.5. While the test is running, you can view the status of the test. F
The autoloader automatically runs an inventory whenever you power it on or insert a magazine. If youneed to run an inventory in addition to this, you
Back to Contents PageFront Panel Administration: Dell™ PowerVault™ 124T LTO6SAS Autoloader User's Guide Configuring the Autoloader SCSI Barcode
17.2 kg (38 lb) loaded (2 magazines, 16 cartridges)Air Quality Minimize sources of particulate contamination. Avoid areas near frequently used doors a
To configure the Dell PowerVault 124T LTO6 SAS autoloader, you must verify the setup of the following:Magazine(s).Ethernet IP address (if you are not
A time server, or set the time and time zone manually (optional)Setting the IP AddressAn IP address is the address of any device attached to a network
5. Press Enter. New Subnet Mask xxx.xxx.xxx.xxx appears on the LCD. You do not need to reboot theautoloader.6. Press Escape or Enter to return to th
6. Press Escape or Enter to return to the Ethernet submenu.Setting the TimeThe system time is displayed by the RMU and it is used internally when log
3. From the Time submenu, scroll to Set Date/Time, and then press Enter. The Date/Time screenappears, allowing you to set the date and time. The curs
3. Scroll to the desired setting (from 0 to 15) and press Enter.4. Press Esc as necessary to return to the main menu. The autoloader does not need
1. From the main menu, scroll to Configuration, and then press Enter.2. From the Configuration menu, scroll to Set Password, and then press Enter.3.
Back to Contents PageDiagnostics: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Diagnostic Tests from the Front Panel Remote Management
1. While the diagnostic test you wish to stop is running, press Escape. The Diagnostics submenudisplays.2. On the submenu, scroll to End Curr. Test,
Loader - Magazine TestLoader - Inventory TestRandom MovesNOTE: The RMU allows you to request all diagnostic tests, but any tests that require a cartri
1 Power switch 2 Media door (mailslot) 3 Front panel LEDs 4 Front panel LCD screen 5 Function keys 6 Left magazine 7 Right magazine (or blank)
Back to Contents PageTroubleshooting: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Before Contacting Customer Support Operator Control
The autoloader doesnot turn on.The power switch at theback of the autoloader isnot turned on.The power cable isdefective or the powersource is malfunc
The applicationsoftware reports afailure locating apiece of media or failsto move a piece ofmedia as requested.The current host backupsoftware or auto
Errors are problems that occur while operating the autoloader. They prevent the autoloader from completing aspecific action. When an error occurs, two
ErrorTypeDescription Recommended ActionAutoloader Operating System Failure Types01 Resource DeletedErrors 01-25 indicate that an unexpected event has
24 Software Error25 Hardware ErrorMessage Error Types26 Message Sender (Task )ID ErrorVerify the host backup application and device driver are at thel
Check support.dell.com for PowerVault 124T firmware updates.If all previous steps fail, see Contacting Dell.38 System Internal I2C HWErrorSee Contacti
42 Media (MAM) Info Error Verify that a valid cartridge type is in use.Repeat operation with a new piece of media.If the operation fails with two diff
61 Drive Login Error Check the TapeAlert log for more specific drive error information.Refer to Table 3 for recommended actions.Power cycle the autolo
74 Block Erase Failed Verify all SAS cable connections between the host andautoloader.Verify no media in drive during update.Power cycle the autoloade
1 SAS cable2 Power cable3 Getting Started Guide4 Emergency Magazine Removal Tool5 Magazine blank (supplied only with a single magazine configuration)
If all previous steps fail, see Contacting Dell.A5 Source Element EmptyVerify that the expected source really does not have a cartridge.Power cycle th
Unit (RMU) or the Operator Control Panel (OCP).Note: The Random Moves test requires a minimum of twocartridges present within the autoloader.If the so
Note: The Random Moves test requires a minimum of twocartridges present within the autoloader.If all previous steps fail, see Contacting Dell.B3 Trans
CE Motor Translation PinJammed ErrorCF Motor Asynchronous StopMagazine Hardware Error TypesD0 Magazine Eject FailedEnsure that the autoloader is resti
Front Panel Error TypesEA LCD Busy Error Possible LCD controller problem, software error, or communication error.Power cycle the autoloader.Run the Ra
FA Diagnostic Error, DriveReporting Write ProtectVerify that valid, not data protected media is present for test.Run the Random Moves test from either
TapeAlert InterpretationIn order to display any combination of TapeAlerts that may be set for any one event, a binary representation isused. The 16 ch
Drive TAflag[01] ReadWarningTapeAlert Log Entry:8000000000000000The tape drive is havingproblems reading data. No datahas been lost, but there hasbeen
If no errors areencountered with thealternate piece ofmedia, retry theoriginal media.Drive TAflag[07]Media LifeTapeAlert Log Entry:0200000000000000The
Drive TAflag[15]Memory Chip InCartridge FailureTapeAlert Log Entry:0002000000000000 The memory in the tapecartridge has failed, whichreduces performan
1 Ethernet cable2 SAS cable3 Power cable 6. Attach the female connector of the power cable to the power connector on the back panel of the autoload
Drive TAflag[22]Expired CleaningMedia TapeAlert Log Entry:0000040000000000The last cleaning cartridge usedin the tape drive has worn out.The cleaning
Drive TAflag[30]Hardware A TapeAlert Log Entry:0000000400000000 The tape drive has a hardwarefault.The drive has ahardware fault thatrequires reset to
Drive TAflag[39]Diagnostics RequiredTapeAlert Log Entry:0000000002000000 hardware fault hardware fault thatmay be identified byextended diagnostics(i.
0000000000000100 Drive TAflag[57]Automation InterfaceFailureTapeAlert Log Entry:0000000000000080 The tape drive has a problemwith the automation inte
To Remove the Autoloader from a Rack1. Loosen the two thumb screws that secure the loader to the front of the rack.2. Using two people, or an approp
Back to Contents PageTechnical Specifications: Dell™ PowerVault™ 124T LTO6SAS Autoloader User's Guide Physical Specifications Autoloader Performa
MCBF 100,000 cartridge load/unload cyclesInterface Serial Attached SCSI (SAS)Initialize elementstatus90 seconds (typical)Typical cycle time < 40 se
Wet BulbOperating 26ºC maximumNonoperating 38ºC maximumAutoloader Power SpecificationsCharacteristic SpecificationLine voltage60 Hz system:
Nonoperating 71 G, 2 ms half-sine, 2 shocks (+/–) per axis, X, Y, ZTape Drive SpecificationsLTO6 SAS Drive SpecificationsDescription LTO6 SASRead/wr
Cartridge dimensions 10.2 x 10.54 x 2.15 cm(4 x 4.15 x .85 in)Read compatibility LTO Ultrium 4, LTO Ultrium 5, and LTO Ultrium 6Write compat
always has the tape drive at LUN 0 and the robot at LUN 1.3. For each LUN that needs to be discovered by Linux, issue the following command:echo &quo
Back to Contents PageGetting Help: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Technical Assistance Dell Enterprise Training and Cert
Online ServicesYou can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORTpage, and fill in the requested detai
Automated Order-Status ServiceTo check on the status of any Dell™ products that you have ordered, you can go to support.dell.com, oryou can call the a
You are responsible for paying shipping expenses. You are also responsible for insuring any productreturned, and you assume the risk of loss during sh
Back to Contents PageOperating the Autoloader: Dell™ PowerVault™ 124T LTO6 SAS AutoloaderUser's Guide Operator's Panel Functionality Using C
2. From the Commands submenu, scroll to Log Out, and then press Enter. Session Complete appears on the LCD.NOTE: You can also press Escape to log out