Dell PowerVault 124T Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Dell PowerVault 124T. Dell PowerVault 124T User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 73
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Dell™ PowerVault124T LTO6 SAS Autoloader User's
Guide
Introduction
Installing the Autoloader
Operating the Autoloader
Remote Management Unit
Front Panel Administration
Diagnostics
Troubleshooting
Technical Specifications
Getting Help
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your system.
Caution: A Caution indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
Warning: A Warning indicates a potential for property damage, personal injury, or death.
Information in this document is subject to change without notice.
© 2005-2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the w ritten permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerVault, Dimension, Inspiron, OptiPlex, Latitude, Dell
Precision, PowerApp, PowerEdge, PowerConnect, and DellNet are trademarks of Dell Inc.; Microsoft, Windows,
Windows NT, and Windows Server are registered trademarks of Microsoft Corporation. DLTtape is a
registered trademark of Quantum Corporation. Adobe is either a registered trademark or trademark of
Adobe Systems Incorporated in the United States and/or other countries. RedHat is a registered trademark
of Red Hat, Inc. Mozilla and Firefox are trademarks of Mozilla.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Initial release: August 2012
Zobrazit stránku 0
1 2 3 4 5 6 ... 72 73

Shrnutí obsahu

Strany 1 - Notes, Cautions, and Warnings

Dell™ PowerVault™ 124T LTO6 SAS Autoloader User'sGuide IntroductionInstalling the AutoloaderOperating the AutoloaderRemote Management UnitFront P

Strany 2 - Choosing a Location

If you select an empty location, No Source Tape appears on the LCD. Choose a different location.If you select a location that is already occupied, Des

Strany 3 - Product Overview

Outward Side of a MagazineThe autoloader will not run unless both magazine bays are properly occupied with either a magazine or a magazine blank. One

Strany 4 - Unpacking the Autoloader

so may cause damage to the magazine or the autoloader.Manually Operating the MagazineThere are tw o white thumbwheels, located on each end of the maga

Strany 5

adhering to the cartridge at any point other than the designated label area.3. Fully insert the cartridge into the slot.When pushing the cartridge in

Strany 6 - Enabling LUN Support in Linux

Viewing Firmware VersionTo view the current firmware version, use the following procedure:1. From the main menu, scroll to Status, and then press Ent

Strany 7

1. From the main menu, scroll to Status, and then press Enter.2. From the Status submenu, scroll to Drive, and then press Enter.3. From the Drive s

Strany 8 - User's Guide

Enabling IPv6 Phase 1The PowerVault 124T autoloader is IPv6 Phase 1 enabled by default.Configuring IPv6 Phase 1From the Operator Panel:Select Configur

Strany 9 - Using Cartridges

If you have successfully tested ping6 using scoped link-local addresses, it is possible that you want to use this addresses also for connections toTCP

Strany 10 - Ejecting a Single Cartridge

Back to Contents PageRemote Management Unit: Dell™ PowerVault™ 124TLTO6 SAS Autoloader User's Guide Remote Management Unit Overview Configuration

Strany 11 - Installing a Magazine

Use of all RMU web pages features requires Java Script to be enabled in the user's web browser.To open the RMU:1. From your computer, open your

Strany 12

Back to Contents PageInstalling the Autoloader: Dell™ PowerVault™ 124T LTO6 SAS Autoloader User's Guide Installation Overview Product Overview I

Strany 13 - Viewing Status Information

4. Administration Lock - provides status regarding RMU security settings. Refer to Client OverlapControl for information on how to configure the Admi

Strany 14 - Viewing Tape Drive Status

To view the compression setting:From any page, click the Configuration heading. The Configuration screen displays. Under theCompression heading, the c

Strany 15 - Internet Protocol Version 6

To set Auto Clean:1. From any page, click the Configuration heading. The Configuration screen displays.2. Scroll to Cleaning Tape.If a check mark ap

Strany 16

or through the RMU. The time zone setting is not lost when powered off.NOTE: Whether the autoloader is connected to a time server or not, if you want

Strany 17

Setting Front Panel Security OptionsWhen you enable the security option, users must enter a password to access the autoloader's front panelfuncti

Strany 18 - Opening the RMU

authorized client list or the overlap control policy.3. Use the drop-down box to select Enable or Disabled.4. Type the IP addresses in the appropria

Strany 19

NOTE: It is recommended that all firmware updated be performed with image files located onthe local system hard drive as opposed to a removable media

Strany 20 - Configuration Page

3. Specify a loop count, if desired. Valid numbers are 1 to 99.4. Click Submit.5. While the test is running, you can view the status of the test. F

Strany 21 - Cleaning Tape

The autoloader automatically runs an inventory whenever you power it on or insert a magazine. If youneed to run an inventory in addition to this, you

Strany 22 - Setting the System Time

Back to Contents PageFront Panel Administration: Dell™ PowerVault™ 124T LTO6SAS Autoloader User's Guide Configuring the Autoloader SCSI Barcode

Strany 23 - Setting Network Options

17.2 kg (38 lb) loaded (2 magazines, 16 cartridges)Air Quality Minimize sources of particulate contamination. Avoid areas near frequently used doors a

Strany 24

To configure the Dell PowerVault 124T LTO6 SAS autoloader, you must verify the setup of the following:Magazine(s).Ethernet IP address (if you are not

Strany 25 - Firmware Page

A time server, or set the time and time zone manually (optional)Setting the IP AddressAn IP address is the address of any device attached to a network

Strany 26 - Running Diagnostics Tests

5. Press Enter. New Subnet Mask xxx.xxx.xxx.xxx appears on the LCD. You do not need to reboot theautoloader.6. Press Escape or Enter to return to th

Strany 27 - Library Operations Page

6. Press Escape or Enter to return to the Ethernet submenu.Setting the TimeThe system time is displayed by the RMU and it is used internally when log

Strany 28 - Set to Home

3. From the Time submenu, scroll to Set Date/Time, and then press Enter. The Date/Time screenappears, allowing you to set the date and time. The curs

Strany 29 - Configuring the Autoloader

3. Scroll to the desired setting (from 0 to 15) and press Enter.4. Press Esc as necessary to return to the main menu. The autoloader does not need

Strany 30 - Setting Ethernet

1. From the main menu, scroll to Configuration, and then press Enter.2. From the Configuration menu, scroll to Set Password, and then press Enter.3.

Strany 31 - Setting the Subnet Mask

Back to Contents PageDiagnostics: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Diagnostic Tests from the Front Panel Remote Management

Strany 32 - Setting the SNMP Server

1. While the diagnostic test you wish to stop is running, press Escape. The Diagnostics submenudisplays.2. On the submenu, scroll to End Curr. Test,

Strany 33 - Setting the Time

Loader - Magazine TestLoader - Inventory TestRandom MovesNOTE: The RMU allows you to request all diagnostic tests, but any tests that require a cartri

Strany 34 - SCSI Barcode Length

1 Power switch 2 Media door (mailslot) 3 Front panel LEDs 4 Front panel LCD screen 5 Function keys 6 Left magazine 7 Right magazine (or blank)

Strany 35 - Setting Passwords

Back to Contents PageTroubleshooting: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Before Contacting Customer Support Operator Control

Strany 36 - Getting Lost Passwords

The autoloader doesnot turn on.The power switch at theback of the autoloader isnot turned on.The power cable isdefective or the powersource is malfunc

Strany 37 - Autoloader User's Guide

The applicationsoftware reports afailure locating apiece of media or failsto move a piece ofmedia as requested.The current host backupsoftware or auto

Strany 38 - RMU Diagnostic Tests

Errors are problems that occur while operating the autoloader. They prevent the autoloader from completing aspecific action. When an error occurs, two

Strany 39 - Diagnostics Using the RMU

ErrorTypeDescription Recommended ActionAutoloader Operating System Failure Types01 Resource DeletedErrors 01-25 indicate that an unexpected event has

Strany 40

24 Software Error25 Hardware ErrorMessage Error Types26 Message Sender (Task )ID ErrorVerify the host backup application and device driver are at thel

Strany 41

Check support.dell.com for PowerVault 124T firmware updates.If all previous steps fail, see Contacting Dell.38 System Internal I2C HWErrorSee Contacti

Strany 42 - Checking for Errors

42 Media (MAM) Info Error Verify that a valid cartridge type is in use.Repeat operation with a new piece of media.If the operation fails with two diff

Strany 43 - Autoloader Logs

61 Drive Login Error Check the TapeAlert log for more specific drive error information.Refer to Table 3 for recommended actions.Power cycle the autolo

Strany 44

74 Block Erase Failed Verify all SAS cable connections between the host andautoloader.Verify no media in drive during update.Power cycle the autoloade

Strany 45

1 SAS cable2 Power cable3 Getting Started Guide4 Emergency Magazine Removal Tool5 Magazine blank (supplied only with a single magazine configuration)

Strany 46

If all previous steps fail, see Contacting Dell.A5 Source Element EmptyVerify that the expected source really does not have a cartridge.Power cycle th

Strany 47

Unit (RMU) or the Operator Control Panel (OCP).Note: The Random Moves test requires a minimum of twocartridges present within the autoloader.If the so

Strany 48

Note: The Random Moves test requires a minimum of twocartridges present within the autoloader.If all previous steps fail, see Contacting Dell.B3 Trans

Strany 49

CE Motor Translation PinJammed ErrorCF Motor Asynchronous StopMagazine Hardware Error TypesD0 Magazine Eject FailedEnsure that the autoloader is resti

Strany 50

Front Panel Error TypesEA LCD Busy Error Possible LCD controller problem, software error, or communication error.Power cycle the autoloader.Run the Ra

Strany 51

FA Diagnostic Error, DriveReporting Write ProtectVerify that valid, not data protected media is present for test.Run the Random Moves test from either

Strany 52

TapeAlert InterpretationIn order to display any combination of TapeAlerts that may be set for any one event, a binary representation isused. The 16 ch

Strany 53

Drive TAflag[01] ReadWarningTapeAlert Log Entry:8000000000000000The tape drive is havingproblems reading data. No datahas been lost, but there hasbeen

Strany 54

If no errors areencountered with thealternate piece ofmedia, retry theoriginal media.Drive TAflag[07]Media LifeTapeAlert Log Entry:0200000000000000The

Strany 55 - TapeAlert Logs

Drive TAflag[15]Memory Chip InCartridge FailureTapeAlert Log Entry:0002000000000000 The memory in the tapecartridge has failed, whichreduces performan

Strany 56 - TapeAlert Logs through RMU

1 Ethernet cable2 SAS cable3 Power cable 6. Attach the female connector of the power cable to the power connector on the back panel of the autoload

Strany 57

Drive TAflag[22]Expired CleaningMedia TapeAlert Log Entry:0000040000000000The last cleaning cartridge usedin the tape drive has worn out.The cleaning

Strany 58

Drive TAflag[30]Hardware A TapeAlert Log Entry:0000000400000000 The tape drive has a hardwarefault.The drive has ahardware fault thatrequires reset to

Strany 59

Drive TAflag[39]Diagnostics RequiredTapeAlert Log Entry:0000000002000000 hardware fault hardware fault thatmay be identified byextended diagnostics(i.

Strany 60

0000000000000100 Drive TAflag[57]Automation InterfaceFailureTapeAlert Log Entry:0000000000000080 The tape drive has a problemwith the automation inte

Strany 61

To Remove the Autoloader from a Rack1. Loosen the two thumb screws that secure the loader to the front of the rack.2. Using two people, or an approp

Strany 62

Back to Contents PageTechnical Specifications: Dell™ PowerVault™ 124T LTO6SAS Autoloader User's Guide Physical Specifications Autoloader Performa

Strany 63

MCBF 100,000 cartridge load/unload cyclesInterface Serial Attached SCSI (SAS)Initialize elementstatus90 seconds (typical)Typical cycle time < 40 se

Strany 64 - Packing the Autoloader

Wet BulbOperating 26ºC maximumNonoperating 38ºC maximumAutoloader Power SpecificationsCharacteristic SpecificationLine voltage60 Hz system:

Strany 65 - Physical Specifications

Nonoperating 71 G, 2 ms half-sine, 2 shocks (+/–) per axis, X, Y, ZTape Drive SpecificationsLTO6 SAS Drive SpecificationsDescription LTO6 SASRead/wr

Strany 66

Cartridge dimensions 10.2 x 10.54 x 2.15 cm(4 x 4.15 x .85 in)Read compatibility LTO Ultrium 4, LTO Ultrium 5, and LTO Ultrium 6Write compat

Strany 67

always has the tape drive at LUN 0 and the robot at LUN 1.3. For each LUN that needs to be discovered by Linux, issue the following command:echo &quo

Strany 68 - Tape Drive Specifications

Back to Contents PageGetting Help: Dell™ PowerVault™ 124T LTO6 SASAutoloader User's Guide Technical Assistance Dell Enterprise Training and Cert

Strany 69

Online ServicesYou can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORTpage, and fill in the requested detai

Strany 70 - Technical Assistance

Automated Order-Status ServiceTo check on the status of any Dell™ products that you have ordered, you can go to support.dell.com, oryou can call the a

Strany 71 - AutoTech Service

You are responsible for paying shipping expenses. You are also responsible for insuring any productreturned, and you assume the risk of loss during sh

Strany 72 - Product Information

Back to Contents PageOperating the Autoloader: Dell™ PowerVault™ 124T LTO6 SAS AutoloaderUser's Guide Operator's Panel Functionality Using C

Strany 73 - Before You Call

2. From the Commands submenu, scroll to Log Out, and then press Enter. Session Complete appears on the LCD.NOTE: You can also press Escape to log out

Komentáře k této Příručce

Žádné komentáře