Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Uživatelská příručka Strana 499

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 931
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 498
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0132
Message CMOS failed.
Detailed
Description
System BIOS detected a failure with CMOS memory during system POST. This exception
occurred early in system power on, thus the system may not display video. (BIOS POST
Exception Code 84)
Recommended
Response Action
Check system event log for CMOS battery exceptions. Remove and reapply input power. If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message CMOS failed. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0133
Message DMA controller failed.
Detailed
Description
System BIOS detected a failure with the DMA controller during system POST. This exception
occurred early in system power on, thus the system may not display video. (BIOS POST
Exception code 85)
Recommended
Response Action
Remove and reapply input power.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message DMA controller failed. Power cycle system
Initial Default. FALSE