Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR17
Message
arg1
format failed.
Arguments
arg1 =
VD Name
Detailed
Description
A physical disk included in the virtual disk failed.
Recommended
Response Action
Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a
red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format
operation.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR18
Message Initialization of
arg1
has failed.
Arguments
arg1 =
virtual disk
Detailed
Description
A physical disk included in the virtual disk has failed or was removed.
Recommended
Response Action
If a physical disk has failed, replace the physical disk. Restart the virtual disk initialization.