Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Uživatelská příručka Strana 649

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 931
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 648
33
RFL Event Messages
RFL2000
Message Internal Dual SD Module
arg1
is present.
Arguments
arg1 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory RFL = IDSDM Media
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RFL2002
Message Internal Dual SD Module
arg1
is offline.
Arguments
arg1 =
name
Detailed
Description
The SD card module is installed but may be improperly installed or configured incorrectly.
Recommended
Response Action
Reinstall the SD module.
Category System Health
SubCategory RFL = IDSDM Media
Severity Severity 2 (Warning)
649
Zobrazit stránku 648
1 2 ... 644 645 646 647 648 649 650 651 652 653 654 ... 930 931

Komentáře k této Příručce