40 System Event Log Messages for IPMI Systems
Processor Status Events
The processor status messages monitor the functionality of the processors in a system. These messages
provide processor health and warning information of a system.
Power Supply Events
The power supply sensors monitor the functionality of the power supplies. These messages provide status
and warning information for power supplies for a particular system.
Table 3-4. Processor Status Events
Event Message Severity Cause
<
Processor Entity
> status processor
sensor IERR, where <
Processor
Entity
> is the processor that
generated the event. For example,
PROC for a single processor system
and PROC # for multiprocessor
system.
Critical IERR internal error generated by the
<Processor Entity>.
<
Processor Entity
> status processor
sensor Thermal Trip.
Critical The processor generates this event before it
shuts down because of excessive heat caused
by lack of cooling or heat synchronizating.
<
Processor Entity
> status processor
sensor recovered from IERR.
Information This event is generated when a processor
recovers from the internal error.
<
Processor Entity
> status processor
sensor disabled.
Warning This event is generated for all processors that
are disabled.
<
Processor Entity
> status processor
sensor terminator not present.
Information This event is generated if the terminator is
missing on an empty processor slot.
Table 3-5. Power Supply Events
Event Message Severity Cause
<
Power Supply Sensor Name
> power
supply sensor removed.
Critical This event is generated when the power
supply sensor is removed.
<
Power Supply Sensor Name
> power
supply sensor AC recovered.
Information This event is generated when the power
supply has been replaced.
<
Power Supply Sensor Name
> power
supply sensor returned to normal
state.
Information This event is generated when the power
supply that failed or removed was replaced
and the state has returned to normal.