Storage Management Message Reference 51
2080 Array disk initialize
failed
Critical /
Failure /
Error
Cause: The array disk has failed or is corrupt.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. Restart the initialization.
904 542
2081 Virtual disk
reconfiguration failed
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk has failed or is corrupt. A user may also
have cancelled the reconfiguration.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. If the array disk is part of a redundant
array, then rebuild the array disk. When
finished, restart the reconfiguration.
1204 543
2082 Virtual disk rebuild
failed
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk has failed or is corrupt. A user may also
have cancelled the rebuild.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. Restart the virtual disk rebuild.
1204 544
2083 Array disk rebuild
failed
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk has failed or is corrupt. A user may also
have cancelled the rebuild.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. Rebuild the virtual disk rebuild.
904 545
2085 Virtual disk check
consistency
completed
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1201 547
2086 Virtual disk format
completed
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1201 548
Table 4-1. Storage Management Messages (continued)