Dell OpenManage Server Administrator Version 2.3 Uživatelská příručka Strana 72

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 106
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 71
74 Storage Management Message Reference
2202 A global hot spare has
been removed.
Warning /
Non-critical
Cause: The controller is unable to
communicate with a disk that is assigned as a
global hot spare. The disk may have been
removed. There may also be a bad or loose
cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables.
If necessary, replace the disk and reassign the
hot spare.
903 None
2203 A dedicated hot spare
failed.
Warning /
Non-critical
Cause: The controller is unable to
communicate with a disk that is assigned as a
dedicated hot spare. The disk may have failed
or been removed. There may also be a bad or
loose cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables.
If necessary, replace the disk and reassign the
hot spare.
903 None
2204 A dedicated hot spare
has been removed.
Warning /
Non-critical
Cause: The controller is unable to
communicate with a disk that is assigned as a
dedicated hot spare. The disk may have been
removed. There may also be a bad or
loose cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables.
If necessary, replace the disk and reassign the
hot spare.
903 None
2205 A dedicated hot spare
has been
automatically
unassigned.
Warning /
Non-critical
Cause: The hot spare is no longer required
because the virtual disk it was assigned to has
been deleted.
Action: None.
903 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number
Zobrazit stránku 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 105 106

Komentáře k této Příručce

Žádné komentáře