Storage Management Message Reference 209
2357 SAS
expander
error: %1
Critical /
Failure /
Error
Cause: The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
firmware and is displayed
with the alert in the Alert
Log. This text can vary
depending on the
situation.
Action: There may be a
problem with the
enclosure. Check the
health of the enclosure and
its components. by selecting
the enclosure object in the
tree view. The Health
subtab displays a red "X" or
yellow exclamation point
for enclosure components
that are failed or degraded.
See the enclosure
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2061
754
2358 The battery
charge cycle
is complete.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)