Dell OpenManage Server Administrator Version 5.5 Uživatelská příručka Strana 97

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 238
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 96
Storage Management Message Reference 97
2076 Virtual disk
Check
Consistency
failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
failed or there is an error in
the parity information. A
failed physical disk can
cause errors in parity
information.
Action: Replace the failed
physical disk. You can
identify which disk has
failed by locating the disk
that has a red “X” for its
status. Rebuild the physical
disk. When finished,
restart the check
consistency operation.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2081
1204
2077 Virtual disk
format failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
failed.
Action: Replace the failed
physical disk. You can
identify which physical disk
has failed by locating the
disk that has a red "X" for
its status. Rebuild the
physical disk. When
finished, restart the virtual
disk format operation.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 237 238

Komentáře k této Příručce

Žádné komentáře