228 omconfig storage Commands
omconfig Blink Virtual Disk
Use the following omconfig command syntax to blink the physical disks
included in a virtual disk.
Complete Syntax
omconfig storage vdisk action=blink controller=id
vdisk=id
where id is the controller ID and virtual disk ID as reported by the omreport
command. To obtain these values, type omreport storage controller to display
the controller IDs and then type omreport storage vdisk controller=ID to
display the IDs for the virtual disks attached to the controller.
Example Syntax
To blink the physical disks in virtual disk 4 on controller 1, type:
omconfig storage vdisk action=blink controller=1
vdisk=4
omconfig Unblink Virtual Disk
Use the following omconfig command syntax to unblink the physical disks
included in a virtual disk.
Complete Syntax
omconfig storage vdisk action=unblink controller=
id vdisk=id
where id is the controller ID and virtual disk ID as reported by the omreport
command. To obtain these values, type omreport storage controller to display
the controller IDs and then type omreport storage vdisk controller=ID to
display the IDs for the virtual disks attached to the controller.
Example Syntax
To blink the physical disks in virtual disk 4 on controller 1, type:
omconfig storage vdisk action=unblink controller=1
vdisk=4