246 omconfig storage Commands
Complete Syntax
omconfig storage controller action=createvdisk
controller=id raid=<c| r0| r1| r1c| r5| r6| r10| r50
|r60> size=<number | max | min> pdisk=<PDISKID>
[stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb|
128kb>] [cachepolicy=<d | c>] [diskcachepolicy=
<disabled | enabled>][readpolicy=<ra | nra | ara |
rc| nrc>] [writepolicy=<wb| wt| wc| nwc | fwb>]
[name=<string>] [spanlength=<n>] |
[secureflag=yes]
NOTE: If you are configuring RAID for SAS controllers with firmware version 6.1
and later, spanlength is an optional parameter (default=2.) Spanlength is an even
number and is lesser than or equal to half the number of physical disks specified
in size.
Parameter Specification for Create and Reconfigure Virtual Disk
The following sections indicate how to specify the omconfig storage controller
action=createvdisk parameters.
controller=id Parameter (Required)
raid=<c| r0| r1| r1c| r5| r6| r10| r50| r60> Parameter (Required)
size=<number | max | min> Parameter (Required)
pdisk=<connector:targetID,connector:targetID,.....> Parameter (Required)
[stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb| 128kb>] Parameter
(Optional)
[cachepolicy=<d | c>] Parameter (Optional)
[readpolicy=<ra| nra| ara| rc| nrc>] Parameter (Optional)
[writepolicy=<wb| wt| wc| nwc | fwb>] Parameter (Optional)
[name=<string>] Parameter (Optional)
[spanlength=<n>] Parameter (Optional)