270 omconfig storage Commands
omconfig Reset All Temperature Probe Thresholds
Use the following omconfig command syntax to reset the minimum and
maximum warning temperature thresholds back to their default value for all
temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=
resetalltempprobes controller=id enclosure=
<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Example Syntax
For example, you may want to reset the thresholds for all temperature probes
in enclosure 2 on controller 1.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to
connector 2 on controller 1. To reset the thresholds for all temperature
probes, type:
omconfig storage enclosure action=
resetalltempprobes controller=1 enclosure=2:3
omconfig Blink
Use the following omconfig command to blink the light-emitting diodes
(LEDs) on the enclosure.
Complete Syntax
omconfig storage enclosure action=blink
controller=id enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.