Storage Management Message Reference 119
2122 Redundancy
degraded
Warning /
Non-critical
Cause: One or more of
the enclosure
components has failed.
For example, a fan or
power supply may have
failed. Although the
enclosure is currently
operational, the failure of
additional components
could cause the
enclosure to fail.
Action: Identify and
replace the failed
component. To identify
the failed component,
select the enclosure in
the tree view and click
the Health subtab.
Any failed component
will be identified with a
red "X" on the
enclosure’s Health
subtab. Alternatively,
you can select the
Storage object and click
the Health subtab.
Clear Alert
Status: 2124.
Related Alert
Number: 2048
LRA Number:
2090
1305