Storage Management Message Reference 199
2313 A power
supply in the
enclosure has
a DC failure.
Warning /
Non-critical
Cause: The power
supply has a DC failure.
Action: Replace the
power supply.
Clear Alert
Number:
2323.
Related Alert
Number:
2122, 2322.
LRA Number:
2090
1003
2314 The
initialization
sequence of
SAS
components
failed during
system
startup. SAS
management
and
monitoring is
not possible.
Critical /
Failure / Error
Cause: Storage
Management is unable
to monitor or manage
SAS devices.
Action: Reboot the
system. If problem
persists, make sure you
have supported versions
of the drivers and
firmware. Also, you may
need to reinstall Storage
Management or Server
Administrator because
of some missing
installation
components.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2051
104
Table 4-4. Storage Management Messages (continued)