94 Storage Management Message Reference
2067 Virtual disk
check
consistency
cancelled
OK / Normal /
Informational
Cause: The check
consistency operation
was cancelled because a
physical disk in the
array has failed or
because a user cancelled
the check consistency
operation.
Action: If the physical
disk failed, then replace
the physical disk. You
can identify which disk
failed by locating the
disk that has a red “X”
for its status. Perform
a rescan after replacing
the disk. When
performing a
consistency check,
be aware that the
consistency check can
take a long time.
The time it takes
depends on the size of
the physical disk or
the virtual disk.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information