Event Message Reference 23
1052 Temperature sensor returned
to a normal value
Sensor location:
<Location in
chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature
sensor on the
backplane board,
system board, or
drive carrier in the
specified system
returned to a valid
range after crossing
a failure threshold.
The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
1053 Temperature sensor detected
a warning value
Sensor location:
<Location in
chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Warning A temperature
sensor on the
backplane board,
system board, CPU,
or drive carrier in
the specified
system exceeded its
warning threshold.
The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
Table 2-2. Temperature Sensor Messages (continued)
Event
ID
Description Severity Cause