Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Uživatelská příručka Strana 175

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 292
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 174
Storage Management Message Reference 175
2280 A disk media
error has been
corrected.
OK / Normal /
Informational
Cause: A disk media
error was detected
while the controller was
completing a
background task. A bad
disk block was
identified. The disk
block has been
remapped.
Action: Consider
replacing the disk.
If you receive this alert
frequently, be sure to
replace the disk. You
should also routinely
back up your data.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1201
2281 Virtual disk has
inconsistent
data.
OK / Normal /
Informational
Cause: The virtual disk
has inconsistent data.
This may be caused
when a power loss or
system shutdown occurs
while data is being
written to the virtual
disk. This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert
Number:
2127
LRA
Number:
None
1201
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 291 292

Komentáře k této Příručce

Žádné komentáře