Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Uživatelská příručka Strana 234

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 292
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 233
234 Storage Management Message Reference
2417
cntd.
NOTE: If the
unrecoverable medium
error has not been
corrected, it may be
reported again by the
system. This error can be
fixed by writing data on
the affected area or
deleting and recreating
the Virtual Disk as
demonstrated in the
following procedure.
1
Back up the data.
2
Delete the Virtual
Disk.
3
Recreate the Virtual
Disk using the same
parameters like size,
RAID level, disks, etc.
4
Restore data.
2418 Disk medium
error on virtual
disk has been
corrected
Informational Cause: This alert is for
informational purposes.
Action: None.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1201
2425 State change
on Physical
disk from
READY to
Non-RAID.
Informational Cause: User triggered
action.
Action: Configure the
drive to be non-raid
using CLI/GUI.
Clear Alert:
None.
Related
Alert: None
LRA
Number:
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 233
1 2 ... 229 230 231 232 233 234 235 236 237 238 239 ... 291 292