2301 The enclosure
has a hardware
error.
Critical /
Failure / Error
Cause: The enclosure or
an enclosure
component is in a
Failed or Degraded
state.
Action: Check the
health of the enclosure
and its components.
Replace any hardware
that is in a Failed state.
See the hardware
documentation for
more information.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2302 The enclosure
is not
responding.
Critical /
Failure / Error
Cause: The enclosure or
an enclosure
component is in a
Failed or Degraded
state.
Action: Check the
health of the enclosure
and its components.
Replace any hardware
that is in a Failed state.
See the hardware
documentation for
more information.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2303 The enclosure
cannot support
both SAS and
SATA physical
disks. Physical
disks may be
disabled.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
851
Table 3-4. Storage Management Messages