Storage Management Message Reference 181
2293 The EMM has
failed.
Critical /
Failure / Error
Cause: The failure may
be caused by a loss of
power to the EMM.
The EMM self test may
also have identified a
failure. There could also
be a firmware problem
or a multi-bit error.
Action: Replace the
EMM. See the hardware
documentation for
information on
replacing the EMM.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2294 A device has
been inserted.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
851
2295 A device has
been removed.
Critical /
Failure / Error
Cause: A device has
been removed and the
system is no longer
functioning in optimal
condition.
Action: Replace the
device.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
Table 3-4. Storage Management Messages