Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Uživatelská příručka Strana 98

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 292
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 97
98 Storage Management Message Reference
2106 SMART FPT
exceeded
Warning /
Non-critical
Cause: A disk on the
specified controller has
received a SMART alert
(predictive failure)
indicating that the disk
is likely to fail in the
near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a
non-redundant virtual
disk, then back up the
data before replacing
the disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Zobrazit stránku 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 291 292