NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN
capabilities of iDRAC from CMC.
Read only for iDRAC on Blade servers.
iDRAC displays only the current VLAN settings and you cannot modify the settings from iDRAC.
All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN
when enabled. No iDRAC configuration change is required to use this external management network
VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
Example
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
cfgNicVLanId (Read or Write)
Description
Specifies the VLAN ID for the network VLAN configuration (in CMC for iDRAC Enterprise on Blade
Servers). This property is only valid if cfgNicVLanEnable is set to 1(enabled).
Read only for iDRAC on Blade servers.
Legal Values
1–4000 and 4021–4094
Default
1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
cfgNicVLanPriority (Read or Write)
Description
Specifies the VLAN Priority for the network VLAN configuration (in CMC for iDRAC Enterprise on
Blade Servers). This property is only valid if cfgNicVLanEnable is set to 1 (enabled).
Read only for iDRAC on Blade servers.
Legal Values
0–7
Default
0
Example
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
cfgDNSDomainNameFromDHCP (Read or Write)
Description
Specifies that iDRAC or CMC DNS domain name must be assigned from the network DHCP server.
Legal Values
1 (TRUE)
0( FALSE)