System.Power.Supply.[i].MaxOutputPower (Read Only)
Description
Displays the DC output rated power in Watts.
Legal Values
Integer > 0
Default
0
System.Power.Supply.[i].Status (Read Only)
Description
Displays the status of the PSU.
Legal Values
0 — absent
1 — present and OK
2 — failure
3 — predictive failure
Default 0 — absent
System.Power.Supply.[i].Type (Read Only)
Description
Displays whether the power supply is AC or DC. Either of them are indexed group and the square
brackets are only place-holders, and do not form a part of command syntax.
Legal Values
String upto 32 characters.
Default
None
System.Power.Supply.[i].LineStatus (Read Only)
Description
Specifies if this power supply is powered off or on.
Legal Values
Integer > 0
Default
None
System.Power.Supply.[i].PMBusMonitoring (Read Only)
Description
Specifies if this PMBus is present or not.
Legal Values
Integer > 0
Default
0
System.ServerOS