cfgRhostsSyslogPowerLoggingEnabled
Description To remote syslog servers, Enables or disables power consumption logging.
This object is applicable only for CMC.
NOTE: Remote syslog must be enabled and more than one remote syslog servers must be
configured to log the power consumption.
Legal Values
1 (enabled)
0 (disabled)
Default
0
cfgRhostsSyslogPowerLoggingInterval
Description Specifies the power consumption collection/logging interval.
This object is applicable only for CMC.
NOTE: This object is applicable only for CMC.
Legal Values
1–1440 (minutes)
Default
5
Example
racadm getconfig -g cfgRemoteHosts [-m server-<n>]
cfgRhostsFwUpdateTftpEnable=1
cfgRhostsFwUpdateIpAddr=0.0.0.0
cfgRhostsFwUpdatePath=
cfgRhostsSmtpServerIpAddr=localhost.localdomain
cfgRhostsNtpEnable=0
cfgRhostsNtpServer1=
cfgRhostsNtpServer2=
cfgRhostsNtpServer3=
cfgRhostsNtpMaxDist=16
cfgRhostsSyslogEnable=0
cfgRhostsSyslogPort=514
cfgRhostsSyslogServer1=
cfgRhostsSyslogServer2=
cfgRhostsSyslogServer3=cfgRhostsSyslogPowerLoggingEnabled=1
cfgRhostsSyslogPowerLoggingInterval=5
cfgUserAdmin
This group provides configuration information about the users who are allowed to access iDRAC or CMC through the
available remote interfaces.
Up to 16 instances of the user group are allowed. Each instance represents the configuration for an individual user.