Zobrazit stránku 49
To display entire information log.
racadm getactiveerrors -s info
Module ID = server-1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected
between system BIOS in slot 4 and CMC.
getarraycfg
Description This command is applicable only for CMC.
To display the storage array properties and configuration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
-m — The valid value for —m <module> is server–n, where n = 1–16.
-s — Query for current storage configuration process status.
Output Array configured properties for:
Member Name
Member IP
Group Name
Group IP
Fabric Selection
<module> configuration completed successfully.
Example
Get the configured storage array properties from server–3.
racadm getarraycfg -m server-3
Query for current storage configuration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description
Displays the asset tag for the chassis.
This subcommand is applicable only for CMC.
50
Zobrazit stránku 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 427 428

Komentáře k této Příručce

Žádné komentáře