Power Group 195
Table 8-19. CPU Power Performance Management Type
Variable Name:
DellCPUPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) CPU power and performance management type is
Maximum Performance.
minPower(2) CPU power and performance management type is
Minimum Power.
osDBPM(4) CPU power and performance management type is
OS Demand Based Power Management.
systemDBPM(8) CPU power and performance management type is
System Demand Based Power Management.
Table 8-20. Memory Power Performance Management Type
Variable Name: DellMemoryPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) Memory power and performance management
type is Maximum Performance.
mhz1333(2) Memory power and performance is 1333 MHz.
mhz1067(4) Memory power and performance is 1067 MHz.
mhz800(8) Memory power and performance is 800 MHz.
minPower(16) Memory power and performance management
type is Minimum Power.